Extracorporeal Automatic Anti-Tachycardia Pacing and Defibrillation for Incessant Ventricular Tachycardia Using a Donated Implantable Cardioverter-Defibrillator

Background: We describe the extracorporeal use of an implantable cardioverter-defibrillator for treatment of post-operative incessant ventricular tachycardia prior to permanent implantable cardioverter-defibrillator implantation and subsequent catheter ablation. Methods & Results: A 54 year-old male, 3 days post aorto-coronary bypass developed hemodynamically unstable, monomorphic fast ventricular tachycardia. Multiple anti-arrhythmics and transcutaneous defibrillations failed to control the rhythm. A pacing/defibrillation lead was inserted and connected extra-corporeally to a donated implantable cardioverter-defibrillator that was programmed at the bedside. 198 episodes of ventricular tachycardia occurred over a 3-day period. Anti-tachycardia pacing sequences terminated 194 episodes (98%). Anti-tachycardia pacing sequences caused ventricular fibrillation in 4 cases. Conclusion: Automatic anti-tachycardia pacing deserves further study in the acute setting.

[1]  W. Grimm,et al.  Antitachycardia Pacing for Spontaneous Rapid Ventricular Tachycardia in Patients with Prophylactic Cardioverter‐Defibrillator Therapy , 2006, Pacing and clinical electrophysiology : PACE.

[2]  R. Canby,et al.  Prospective Randomized Multicenter Trial of Empirical Antitachycardia Pacing Versus Shocks for Spontaneous Rapid Ventricular Tachycardia in Patients With Implantable Cardioverter-Defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) Trial Results , 2004, Circulation.

[3]  Brian Baker,et al.  Quality of life in the Canadian Implantable Defibrillator Study (CIDS). , 2002, American heart journal.

[4]  Judy Powell,et al.  Quality of Life in the Antiarrhythmics Versus Implantable Defibrillators Trial: Impact of Therapy and Influence of Adverse Symptoms and Defibrillator Shocks , 2002, Circulation.

[5]  Michael O. Sweeney,et al.  Shock Reduction Using Antitachycardia Pacing for Spontaneous Rapid Ventricular Tachycardia in Patients With Coronary Artery Disease , 2001, Circulation.

[6]  D. Kuchar,et al.  Bedside pacetermination of arrhythmias using an explanted automatic defibrillator. , 1999, Australian and New Zealand journal of medicine.

[7]  J. Windle,et al.  Quality‐of‐Life Six Months After CABG Surgery in Patients Randomized to ICD Versus No ICD Therapy: Findings from the CABG Patch Trial , 1999, Pacing and clinical electrophysiology : PACE.

[8]  J. Merino,et al.  Randomized, prospective comparison of four burst pacing algorithms for spontaneous ventricular tachycardia. , 1998, The American journal of cardiology.

[9]  A. Schaumann,et al.  Empirical versus tested antitachycardia pacing in implantable cardioverter defibrillators: a prospective study including 200 patients. , 1998, Circulation.

[10]  N. Earle,et al.  Spontaneous Ventricular Tachycardia Treated by Antitachycardia Pacing , 1997 .

[11]  Jens Jung,et al.  Safety of Antitachycardia Pacing in Patients with Implantable Cardioverter Defibrillators and Severely Depressed Left Ventricular Function , 1995, Pacing and clinical electrophysiology : PACE.

[12]  C. Morillo,et al.  A prospective randomized comparison of autodecremental pacing to burst pacing in device therapy for chronic ventricular tachycardia secondary to coronary artery disease. , 1993, The American journal of cardiology.

[13]  M. Borggrefe,et al.  Clinical experience with antitachycardia pacing and improved detection algorithms in a new implantable cardioverter-defibrillator. , 1993, Journal of the American College of Cardiology.

[14]  J. Porterfield,et al.  Conversion Rates of Induced Versus Spontaneous Ventricular Tachycardia by a Third Generation Cardioverter Defibrillator , 1993, Pacing and clinical electrophysiology : PACE.

[15]  R. Luceri,et al.  Changing Trends in Therapy Delivery with a Third Generation Noncommitted Implantable Defibrillator: Results of a Large Single Center Clinical Trial , 1993, Pacing and clinical electrophysiology : PACE.

[16]  H. Trappe,et al.  Clinical Efficacy and Safety of the New Cardioverter Defibrillator Systems , 1993, Pacing and clinical electrophysiology : PACE.

[17]  A. Greenspon,et al.  Programmable External Automatic Antitachycardia Pacing as a Bridge to Definitive Therapy in Patients with Recurrent Sustained Ventricular Tachycardia , 1992, Pacing and clinical electrophysiology : PACE.

[18]  A. Camm,et al.  Efficacy of Automatic Multimodal Device Therapy for Ventricular Tachyarrhythmias as Delivered by a New Implantable Pacing Cardioverter‐Defibrillator: Results of a European Multicenter Study of 102 Implants , 1992, Circulation.

[19]  P. Kudenchuk,et al.  Clinical Experience With a Tiered‐Therapy, Multiprogrammable Antiarrhythmia Device , 1992, Circulation.

[20]  G. Guiraudon,et al.  Reduction in defibrillator shocks with an implantable device combining antitachycardia pacing and shock therapy. , 1991, Journal of the American College of Cardiology.

[21]  Iroon Polytechniou Influence of cultivation temperature on the ligninolytic activity of selected fungal strains , 2006 .