Analysis and Correction of Pressure Wave Distortion in Fluid‐Filled Catheter Systems

Dynamic characteristics of a variety of catheters and their dependence on various operating parameters are presented. Careful flushing of the catheter with degassed water or saline considerably improves the performance of these systems. The operating temperature, number of catheter uses, and average transmural pressure difference do not have a significant effect.The error due to catheter distortion in commonly used left ventricular performance indices (end diastolic pressure, peak systolic pressure, maximum dp/dt and Vmax) was assessed. On the basis of these results, it is shown that the natural frequency of the catheter system must be greater than 40 Hz to produce results accurate to 10%.The experimental data were used to develop a semi-empirical model for the catheter transducer system. This model was used in the design of an analog compensator to further improve the dynamic characteristics of the catheter transducer system. The compensator requires only two parameter settings, catheter natural frequency and damping ratio.

[1]  R. Mates,et al.  Vmax as an Index of Contractile State in Man , 1971, Circulation.

[2]  D. L. Fry,et al.  Physiologic recording by modern instruments with particular reference to pressure recording. , 1960, Physiological reviews.

[3]  I. Mirsky Vmax as an Index of Contractile State in Man , 1971, Circulation.

[4]  L. J. Krovetz,et al.  Damped and undamped frequency responses of underdamped catheter manometer systems. , 1970, American heart journal.

[5]  D. A. Mcdonald,et al.  A CRITICAL STUDY OF THE RESPONSE OF MANOMETERS TO FORCED OSCILLATIONS. , 1963, Physics in medicine and biology.

[6]  C. Hahn,et al.  Physical criteria for measurement of left ventricular pressure and its first derivative. , 1971, Cardiovascular research.

[7]  D T Mason,et al.  Usefulness and limitations of the rate of rise of intraventricular pressure (dp-dt) in the evaluation of myocardial contractility in man. , 1969, The American journal of cardiology.

[8]  H. Dear,et al.  Accurate method for measuring dP-dt with cardiac catheters and external transducers. , 1971, Journal of applied physiology.

[9]  An Evaluation of Modern Pressure Recording Systems , 1957, Circulation research.

[10]  J Ross,et al.  Contractile State of the Left Ventricle in Man: Instantaneous Tension‐Velocity‐Length Relations in Patients With And Without Disease of the Left Ventricular Myocardium , 1968, Circulation research.

[11]  H. W. Shirer,et al.  Blood pressure measuring methods. , 1962, IRE transactions on bio-medical electronics.

[12]  E. Sonnenblick,et al.  Myocardial Force‐Velocity Relationships in Clinical Heart Disease , 1970, Circulation.