Deterministic phase retrieval employing spherical illumination

Deterministic Phase Retrieval techniques (DPRTs) employ a series of paraxial beam intensities in order to recover the phase of a complex field. These paraxial intensities are usually generated in systems that employ plane-wave illumination. This type of illumination allows a direct processing of the captured intensities with DPRTs for recovering the phase. Furthermore, it has been shown that intensities for DPRTs can be acquired from systems that use spherical illumination as well. However, this type of illumination presents a major setback for DPRTs: the captured intensities change their size for each position of the detector on the propagation axis. In order to apply the DPRTs, reescalation of the captured intensities has to be applied. This condition can increase the error sensitivity of the final phase result if it is not carried out properly. In this work, we introduce a novel system based on a Phase Light Modulator (PLM) for capturing the intensities when employing spherical illumination. The proposed optical system enables us to capture the diffraction pattern of under, in, and over-focus intensities. The employment of the PLM allows capturing the corresponding intensities without displacing the detector. Moreover, with the proposed optical system we can control accurately the magnification of the captured intensities. Thus, the stack of captured intensities can be used in DPRTs, overcoming the problems related with the resizing of the images. In order to prove our claims, the corresponding numerical experiments will be carried out. These simulations will show that the retrieved phases with spherical illumination are accurate and can be compared with those that employ plane wave illumination. We demonstrate that with the employment of the PLM, the proposed optical system has several advantages as: the optical system is compact, the beam size on the detector plane is controlled accurately, and the errors coming from mechanical motion can be suppressed easily.

[1]  Françoise Peyrin,et al.  Regularization of Phase Retrieval With Phase-Attenuation Duality Prior for 3-D Holotomography , 2010, IEEE Transactions on Image Processing.

[2]  A. Asundi,et al.  High-speed transport-of-intensity phase microscopy with an electrically tunable lens. , 2013, Optics express.

[3]  S. Wilkins,et al.  Linear algorithms for phase retrieval in the Fresnel region , 2004 .

[4]  Keith A. Nugent,et al.  The measurement of phase through the propagation of intensity: an introduction , 2011 .

[5]  J R Fienup,et al.  Phase retrieval algorithms: a comparison. , 1982, Applied optics.

[6]  T Salditt,et al.  Transport of intensity phase reconstruction to solve the twin image problem in holographic x-ray imaging. , 2013, Optics express.

[7]  N. Streibl Phase imaging by the transport equation of intensity , 1984 .

[8]  T. Gaylord,et al.  Multifilter phase imaging with partially coherent light. , 2014, Applied optics.

[9]  P. Cloetens,et al.  Quantitative comparison of direct phase retrieval algorithms in in-line phase tomography. , 2008, Medical physics.

[10]  Anton Barty,et al.  The holographic twin image problem: a deterministic phase solution , 2000 .

[11]  M. Anastasio,et al.  Image reconstruction in lens-based intensity diffraction tomography. , 2009, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  M. Teague Deterministic phase retrieval: a Green’s function solution , 1983 .

[13]  C. Falldorf,et al.  Automated compensation of misalignment in phase retrieval based on a spatial light modulator. , 2011, Applied optics.

[14]  Malgorzata Kujawinska,et al.  Computation of highly off-axis diffracted fields using the band-limited angular spectrum method with suppressed Gibbs related artifacts. , 2013, Applied optics.

[15]  Optimization of waveguide optics for lensless x-ray imaging , 2011 .

[16]  K K W Siu,et al.  The projection approximation and edge contrast for x-ray propagation-based phase contrast imaging of a cylindrical edge. , 2010, Optics express.

[17]  Andrew R. Harvey,et al.  Validity of Fresnel and Fraunhofer approximations in scalar diffraction , 2003 .

[18]  Nikolay V. Petrov,et al.  Comparison of digital holography and iterative phase retrieval methods for wavefront reconstruction , 2014, Photonics Asia.

[19]  M. Kujawińska,et al.  Capture and display mismatch compensation for real-time digital holographic interferometry. , 2014, Applied optics.

[20]  Malgorzata Kujawinska,et al.  Accelerated single-beam wavefront reconstruction techniques based on relaxation and multiresolution strategies. , 2013, Optics letters.

[21]  A. Asundi,et al.  Noninterferometric single-shot quantitative phase microscopy. , 2013, Optics letters.

[22]  T. Kozacki,et al.  Optimum measurement criteria for the axial derivative intensity used in transport of intensity-equation-based solvers. , 2014, Optics letters.

[23]  Konstantinos Falaggis,et al.  Self-calibrating common-path interferometry. , 2015, Optics express.

[24]  Michael Frankfurter,et al.  Optical Shop Testing , 2016 .

[25]  L. M. Voortman,et al.  When to use the projection assumption and the weak-phase object approximation in phase contrast cryo-EM. , 2014, Ultramicroscopy.

[26]  P. Cloetens,et al.  Mixed transfer function and transport of intensity approach for phase retrieval in the Fresnel region. , 2007, Optics letters.

[27]  K. Nugent,et al.  A Phase Odyssey , 2001 .

[28]  S. Wilkins,et al.  Contrast and resolution in imaging with a microfocus x-ray source , 1997 .

[29]  Corinne Fournier,et al.  Twin-image noise reduction by phase retrieval in in-line digital holography , 2005, SPIE Optics + Photonics.

[30]  K. Nugent,et al.  Quantitative phase-sensitive imaging in a transmission electron microscope , 2000, Ultramicroscopy.

[31]  T. Kozacki,et al.  Optimum plane selection for transport-of-intensity-equation-based solvers. , 2014, Applied optics.

[32]  Rene A. Claus,et al.  Transport of Intensity phase imaging by intensity spectrum fitting of exponentially spaced defocus planes. , 2014, Optics express.

[33]  Myung K. Kim,et al.  Digital Holographic Microscopy , 2007 .

[34]  Timur E. Gureyev,et al.  On x-ray phase imaging with a point source , 1998 .

[35]  A. Barty,et al.  Quantitative phase‐amplitude microscopy. III. The effects of noise , 2004, Journal of microscopy.

[36]  Bob Nagler,et al.  Focusing XFEL SASE pulses by rotationally parabolic refractive x-ray lenses , 2014 .