Modulated beam conformal therapy for head and neck tumors.

PURPOSE The goal of modulated-beam conformal therapy is to reduce the dose to healthy tissue and sensitive structures around a uniformly irradiated target volume. Multiple intensity-modulated fields offer improved tissue-sparing dose distributions. New computer-based systems for planning and delivering such treatments may soon be available from different commercial sources that will make the formulation of an intensity-modulated treatment plan and its execution widely available at any treatment facility that has the resources to acquire the necessary equipment. This work reports on a study of the integration of two such systems. METHODS AND MATERIALS Treatment planning was done using a commercially available inverse planning algorithm based on simulated annealing. The plans arbitrarily assumed nine coplanar x-ray beams at nonopposed gantry angles. Intensity modulation was computed for each beam. The modulated field at each gantry angle was broken down into a series of uniform (nonmodulated) subfields, which could be delivered as a sequence to produce the desired dose distribution. Because a large number of subfields was delivered, a multileaf collimator (MLC) was used for field shaping. This allowed rapid and accurate field shaping for treatments made up of several hundred subfields. Computer control of the MLC and linear accelerator allowed delivery of doses less than .01 Gy per subfield. Treatment was delivered on a prototype, computer-controlled accelerator and MLC system. Resulting dose distributions were analyzed using film and an anatomically specific, homogeneous phantom. RESULTS The treatment plans were evaluated using dose-volume histogram analysis. The plans provided acceptably uniform irradiation of the target volume without exceeding dose tolerances for nearby critical structures. The plans were successfully delivered by a prototype dynamic MLC. The time needed to deliver a sequence of subfields at one gantry angle ranged from 0.7 to 2.0 min. Isodoses from film agreed reasonably well with planned isodose distributions. CONCLUSIONS It is feasible to plan and deliver fixed gantry, modulated-beam conformal therapy for head and neck tumors with systems being developed commercially. The planned dose distributions exhibit significant potential for sparing closely spaced normal tissue structures in the head and neck.

[1]  T. Bortfeld,et al.  Methods of image reconstruction from projections applied to conformation radiotherapy. , 1990, Physics in medicine and biology.

[2]  S Takahashi,et al.  Conformation radiotherapy. Rotation techniques as applied to radiography and radiotherapy of cancer. , 1965, Acta radiologica: diagnosis.

[3]  D. Convery,et al.  The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation , 1992 .

[4]  Cedric X. Yu,et al.  Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. , 1995, Physics in medicine and biology.

[5]  A Brahme,et al.  Shaping of arbitrary dose distributions by dynamic multileaf collimation. , 1988, Physics in medicine and biology.

[6]  H. Suit,et al.  The importance of optimal treatment planning in radiation therapy. , 1991, International journal of radiation oncology, biology, physics.

[7]  S A Leibel,et al.  The effect of local-regional control on distant metastatic dissemination in carcinoma of the head and neck: results of an analysis from the RTOG head and neck database. , 1991, International journal of radiation oncology, biology, physics.

[8]  T. Bortfeld,et al.  X-ray field compensation with multileaf collimators. , 1994, International journal of radiation oncology, biology, physics.

[9]  T LoSasso,et al.  The use of a multi-leaf collimator for conformal radiotherapy of carcinomas of the prostate and nasopharynx. , 1993, International journal of radiation oncology, biology, physics.

[10]  R Mohan,et al.  Improved dose distributions for 3D conformal boost treatments in carcinoma of the nasopharynx. , 1991, International journal of radiation oncology, biology, physics.

[11]  A L Boyer,et al.  Use of a multileaf collimator as a dynamic missing-tissue compensator. , 1996, Medical physics.

[12]  R Svensson,et al.  An analytical solution for the dynamic control of multileaf collimators. , 1994, Physics in medicine and biology.

[13]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[14]  R Mohan,et al.  The biological basis for conformal three-dimensional radiation therapy. , 1991, International journal of radiation oncology, biology, physics.

[15]  H. Sandler,et al.  Potential improvement in the results of irradiation for prostate carcinoma using improved dose distribution. , 1992, International journal of radiation oncology, biology, physics.

[16]  S. Webb Optimization by simulated annealing of three-dimensional, conformal treatment planning for radiation fields defined by a multileaf collimator: II. Inclusion of two-dimensional modulation of the x-ray intensity. , 1992, Physics in medicine and biology.