Quantification of Chronic Functional Mitral Regurgitation by Automated 3-Dimensional Peak and Integrated Proximal Isovelocity Surface Area and Stroke Volume Techniques Using Real-Time 3-Dimensional Volume Color Doppler Echocardiography: In Vitro and Clinical Validation

Background—The aim of this study was to test the accuracy of an automated 3-dimensional (3D) proximal isovelocity surface area (PISA) (in vitro and patients) and stroke volume technique (patients) to assess mitral regurgitation (MR) severity using real-time volume color flow Doppler transthoracic echocardiography. Methods and Results—Using an in vitro model of MR, the effective regurgitant orifice area and regurgitant volume (RVol) were measured by the PISA technique using 2-dimensional (2D) and 3D (automated true 3D PISA) transthoracic echocardiography. The mean anatomic regurgitant orifice area (0.35±0.10 cm2) was underestimated to a greater degree by the 2D (0.12±0.05 cm2) than the 3D method (0.25±0.10 cm2; P<0.001 for both). Compared with the flowmeter (40±14 mL), the RVol by 2D PISA (20±19 mL) was underestimated (P<0.001), but the 3D peak (43±16 mL) and integrated PISA-based (38±14 mL) RVol were comparable (P>0.05 for both). In patients (n=30, functional MR), 3D effective regurgitant orifice area correlated well with cardiac magnetic resonance imaging RVol r=0.84 and regurgitant fraction r=0.80. Compared with cardiac magnetic resonance imaging RVol (33±22 mL), the integrated PISA RVol (34±26 mL; P=0.42) was not significantly different; however, the peak PISA RVol was higher (48±27 mL; P<0.001). In addition, RVol calculated as the difference in automated mitral and aortic stroke volumes by real-time 3D volume color flow Doppler echocardiography was not significantly different from cardiac magnetic resonance imaging (34±21 versus 33±22 mL; P=0.33). Conclusions—Automated real-time 3D volume color flow Doppler based 3D PISA is more accurate than the 2D PISA method to quantify MR. In patients with functional MR, the 3D RVol by integrated PISA is more accurate than a peak PISA technique. Automated 3D stroke volume measurement can also be used as an adjunctive method to quantify MR severity.

[1]  W. Zoghbi,et al.  Three-dimensional ultrasound imaging model of mitral valve regurgitation: design and evaluation. , 2008, Ultrasound in medicine & biology.

[2]  A P Yoganathan,et al.  Review of hydrodynamic principles for the cardiologist: applications to the study of blood flow and jets by imaging techniques. , 1988, Journal of the American College of Cardiology.

[3]  C. Stroszczynski,et al.  Direct visualization of regurgitant orifice by CMR reveals differential asymmetry according to etiology of mitral regurgitation. , 2011, JACC. Cardiovascular imaging.

[4]  W. Zoghbi,et al.  In vitro validation of real-time three-dimensional color Doppler echocardiography for direct measurement of proximal isovelocity surface area in mitral regurgitation. , 2007, The American journal of cardiology.

[5]  L. Christiaens,et al.  Quantitative assessment of regurgitant flow with total digital three-dimensional reconstruction of color Doppler flow in the convergent region: in vitro validation. , 2002, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[6]  R. Baumann,et al.  Use of 3-dimensional color Doppler echocardiography to measure stroke volume in human beings: comparison with thermodilution. , 2007, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  T. Ryan,et al.  Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging. , 2012, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[8]  James D. Thomas,et al.  Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience. , 2003, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[9]  Leo Grady,et al.  Regurgitation Quantification Using 3D PISA in Volume Echocardiography , 2011, MICCAI.

[10]  Mordehay Vaturi,et al.  Proximal flow convergence region as assessed by real-time 3-dimensional echocardiography: challenging the hemispheric assumption. , 2007, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[11]  K. Willson,et al.  True shape and area of proximal isovelocity surface area (PISA) when flow convergence is hemispherical in valvular regurgitation. , 2000, International journal of cardiology.

[12]  N. Rofsky,et al.  Severity of mitral and aortic regurgitation as assessed by cardiovascular magnetic resonance: optimizing correlation with Doppler echocardiography. , 2006, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[13]  N. Obuchowski Receiver operating characteristic curves and their use in radiology. , 2003, Radiology.

[14]  S. Ray The echocardiographic assessment of functional mitral regurgitation. , 2010, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[15]  F. Netter,et al.  Supplemental References , 2002, We Came Naked and Barefoot.

[16]  James D. Thomas,et al.  Determination of regurgitant orifice area with the use of a new three-dimensional flow convergence geometric assumption in functional mitral regurgitation. , 2008, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[17]  Jeroen J. Bax,et al.  Quantitative Assessment of Mitral Regurgitation: Comparison Between Three-Dimensional Transesophageal Echocardiography and Magnetic Resonance Imaging , 2010, Circulation. Cardiovascular imaging.

[18]  Raimund Erbel,et al.  Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta. , 2008, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[19]  J. Zamorano,et al.  European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 2: mitral and tricuspid regurgitation (native valve disease). , 2010, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[20]  E. Schwammenthal,et al.  Mechanism of dynamic regurgitant orifice area variation in functional mitral regurgitation: physiologic insights from the proximal flow convergence technique. , 1999, Journal of the American College of Cardiology.

[21]  R. Levine,et al.  American Society of Echocardiography: recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography , 2003 .

[22]  Dorin Comaniciu,et al.  Automatic cardiac flow quantification on 3D volume color Doppler data , 2011, 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[23]  J. Zamorano,et al.  Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study. , 2012, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[24]  E. Nagel,et al.  Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols , 2008, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[25]  H F Li,et al.  Magnetic resonance imaging assessment of the severity of mitral regurgitation. Comparison with invasive techniques. , 1995, Circulation.

[26]  D. Hoaglin,et al.  Fine-Tuning Some Resistant Rules for Outlier Labeling , 1987 .

[27]  P. Hunold,et al.  Effect of dynamic flow rate and orifice area on mitral regurgitant stroke volume quantification using the proximal isovelocity surface area method. , 2008, Journal of the American College of Cardiology.

[28]  Takahiro Shiota,et al.  Geometry of the proximal isovelocity surface area in mitral regurgitation by 3-dimensional color Doppler echocardiography: difference between functional mitral regurgitation and prolapse regurgitation. , 2008, American heart journal.

[29]  R. Levine,et al.  Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography. , 2003, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[30]  R. Siegel,et al.  Reproducibility of proximal isovelocity surface area, vena contracta, and regurgitant jet area for assessment of mitral regurgitation severity. , 2010, JACC. Cardiovascular imaging.