Accuracy of single-photon emission computed tomography myocardial perfusion imaging in patients with stents in native coronary arteries.
暂无分享,去创建一个
T D Miller | R. Gibbons | D. Hodge | D. Holmes | T. Miller | J. Milavetz | D R Holmes | D O Hodge | J J Milavetz | R J Gibbons
[1] M. Kern,et al. Continuous coronary flow velocity monitoring during coronary interventions: velocity trend patterns associated with adverse events. , 1994, American heart journal.
[2] M. Leon,et al. Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study. , 1996, Circulation.
[3] M. Leon,et al. Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis. , 1995, Journal of the American College of Cardiology.
[4] Cass Principal Investigators and Their Associates. Myocardial infarction and mortality in the coronary artery surgery study (CASS) randomized trial. , 1984, The New England journal of medicine.
[5] P. Britson,et al. Validation of a new UNIX-based quantitative coronary angiographic system for the measurement of coronary artery lesions. , 1997, Catheterization and cardiovascular diagnosis.
[6] E. Milan,et al. Technetium-99m-sestamibi SPECT to detect restenosis after successful percutaneous coronary angioplasty. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[7] Thomas R. Bruce,et al. Usefulness of tomographic thallium-201 imaging for detection of restenosis after percutaneous transluminal coronary angioplasty. , 1990, The American journal of cardiology.
[8] N. Danchin,et al. Usefulness of exercise SPECT-thallium to detect asymptomatic restenosis in patients who had angina before coronary angioplasty. , 1993, American heart journal.
[9] P. Teirstein,et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. , 1994, The New England journal of medicine.
[10] W Rutsch,et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. , 1994, The New England journal of medicine.
[11] H Yokoi,et al. Three-year follow-up after implantation of metallic coronary-artery stents. , 1996, The New England journal of medicine.
[12] K. Robinson,et al. Coronary intimal proliferation after balloon injury and stenting in swine: an animal model of restenosis. , 1992, Journal of the American College of Cardiology.
[13] J. Zamorano,et al. Vessel wall changes in the proximal non-treated segment after PTCA. An in vivo intracoronary ultrasound study. , 1994, European heart journal.
[14] Richard P. Lewis,et al. Guidelines for clinical use of cardiac radionuclide imaging. Report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Committee on Radionuclide Imaging), developed in collaboration with the American Soci , 1995, Journal of the American College of Cardiology.
[15] David J. Feild. Guidelines for exercise testing. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Cardiovascular Procedures (Subcommitte on Exercise Testing). , 1986, Journal of the American College of Cardiology.
[16] Richard P. Lewis,et al. Guidelines for clinical use of cardiac radionuclide imaging: A report of the American College of Cardiology/American Heart Association Task Force on assessment of diagnostic and therapeutic cardiovascular procedures (committee on radionuclide imaging) — Developed in collaboration with the American S , 1995, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[17] M. Leon,et al. Can coronary flow parameters after stent placement predict restenosis? , 1995, Catheterization and cardiovascular diagnosis.
[18] D. Baim,et al. Long-term (4- to 6-year) outcome of Palmaz-Schatz stenting: paucity of late clinical stent-related problems. , 1996, Journal of the American College of Cardiology.
[19] K. Bailey,et al. Noninvasive identification of severe coronary artery disease using exercise tomographic thallium-201 imaging. , 1992, The American journal of cardiology.
[20] D. Baim,et al. Mechanisms of restenosis and redilation within coronary stents--quantitative angiographic assessment. , 1993, Journal of the American College of Cardiology.
[21] M. Leon,et al. Emergent Use of Balloon‐Expandable Coronary Artery Stenting for Failed Percutaneous Transluminal Coronary Angioplasty , 1992, Circulation.
[22] S. Ellis,et al. Subacute stent thrombosis: evolving issues and current concepts. , 1996, Journal of the American College of Cardiology.
[23] R. Erbel,et al. Comparison of myocardial perfusion reserve before and after coronary balloon predilatation and after stent implantation in patients with postangioplasty restenosis. , 1996, Circulation.
[24] H. Hecht,et al. Silent ischemia after coronary angioplasty: evaluation of restenosis and extent of ischemia in asymptomatic patients by tomographic thallium-201 exercise imaging and comparison with symptomatic patients. , 1991, Journal of the American College of Cardiology.