Voltammetric characterisation of silicon-based microelectrode arrays and their application to mercury-free stripping voltammetry of copper ions.

This paper describes the electrochemical characterisation of a range of gold and platinum microelectrode arrays (MEAs) fabricated by standard photolithographic methods. The inter-electrode spacing, geometry, numbers and dimensions of the electrodes in the arrays were found to influence the voltammetric behaviours obtained. Excellent correlation was found between experimental data and theoretical predictions employing published models of microelectrode behaviour. Gold MEAs were evaluated for their applicability to copper determination in a soil extract sample, where agreement was found between the standard analytical method and a method based on underpotential deposition-anodic stripping voltammetry (UPD-ASV) at the MEAs, offering a mercury-free alternative for copper sensing.

[1]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[2]  R. McCarley,et al.  Characteristics of nanoscopic Au band electrodes , 2002 .

[3]  R. Hintsche,et al.  Development of an ultramicroelectrode arrays (UMEAs) sensor for trace heavy metal measurement in water , 2004 .

[4]  S. Kounaves,et al.  Voltammetric measurement of arsenic in natural waters. , 2002, Talanta.

[5]  Milena Koudelka-Hep,et al.  Microelectrode sensors for biomedical and environmental applications , 2000 .

[6]  Jonathan M Cooper,et al.  Optimization of the geometry and porosity of microelectrode arrays for sensor design. , 2002, Analytical chemistry.

[7]  I. Rubinstein,et al.  Physical electrochemistry : principles, methods, and applications , 1995 .

[8]  Gregory T. A. Kovacs,et al.  Microfabricated electrochemical analysis system for heavy metal detection , 1996 .

[9]  D. Arrigan,et al.  Effect of humic acid on the underpotential deposition-stripping voltammetry of copper in acetic acid soil extract solutions at mercaptoacetic acid-modified gold electrodes , 2004 .

[10]  D. Arrigan,et al.  Determination of trace metals by underpotential deposition–stripping voltammetry at solid electrodes , 2005 .

[11]  Robert B. Darling,et al.  Multi-element heavy metal ion sensors for aqueous solutions , 1999 .

[12]  Gregory T. A. Kovacs,et al.  Field Evaluation of an Electrochemical Probe for in Situ Screening of Heavy Metals in Groundwater , 1998 .

[13]  Dennis G. Peters,et al.  Faradaic electrochemistry at microcylinder, band, and tubular band electrodes , 1985 .

[14]  S. Kounaves,et al.  Microfabricated Ultramicroelectrode Arrays: Developments, Advances, and Applications in Environmental Analysis , 2000 .

[15]  A. Tang Fundamentals of Electroanalytical Chemistry , 2003 .

[16]  Alan Mathewson,et al.  Voltammetric behaviour at gold electrodes immersed in the BCR sequential extraction scheme media: Application of underpotential deposition–stripping voltammetry to determination of copper in soil extracts , 2004 .

[17]  John Alderman,et al.  AN ENVIRONMENTAL MONITORING SYSTEM FOR TRACE METALS USING STRIPPING VOLTAMMETRY , 1998 .

[18]  Joseph Wang,et al.  Real-time electrochemical monitoring: toward green analytical chemistry. , 2002, Accounts of chemical research.

[19]  C. Pasquini,et al.  Multi-electrode detection in voltammetry , 1999 .

[20]  J. W. Schultze,et al.  Passivation and corrosion of microelectrode arrays , 1999 .

[21]  N. I. Kanjuk,et al.  Multienzyme electrochemical sensor array for determination of heavy metal ions , 1999 .

[22]  W. Heineman,et al.  Laboratory techniques in electroanalytical chemistry , 1984 .

[23]  M. Khakani,et al.  Effect of the Microelectrode Geometry on the Diffusion Behavior and the Electroanalytical Performance of Hg‐Electroplated Iridium Microelectrode Arrays Intended for the Detection of Heavy Metal Traces , 2001 .

[24]  W. Kutner,et al.  Microelectrodes. Definitions, characterization, and applications (Technical report) , 2000 .

[25]  Martin Hill,et al.  Development of a portable electroanalytical system for the stripping voltammetry of metals : Determination of copper in acetic acid soil extracts , 2005 .

[26]  Trevor J. Davies,et al.  The cyclic and linear sweep voltammetry of regular and random arrays of microdisc electrodes: Theory , 2005 .

[27]  C. G. Zoski Ultramicroelectrodes: Design, Fabrication, and Characterization , 2002 .

[28]  J. Heinze Ultramicroelectrodes in Electrochemistry , 1993 .

[29]  P. Delahay,et al.  Advances in Electrochemistry and Electrochemical Engineering , 1964 .

[30]  Karl Cammann,et al.  Characterization of microelectrode arrays by means of electrochemical and surface analysis methods , 1997 .

[31]  C. Banks,et al.  The cyclic and linear sweep voltammetry of regular arrays of microdisc electrodes : Fitting of experimental data , 2005 .

[32]  Richard G. Compton,et al.  Diffusional mass transport to microband electrodes of practical geometries: A simulation study using the strongly implicit procedure , 1995 .

[33]  Milena Koudelka-Hep,et al.  Mercury-Plated Iridium-Based Microelectrode Arrays for Trace Metals Detection by Voltammetry: Optimum Conditions and Reliability , 1996 .

[34]  G. Wittstock,et al.  Sensor arrays and array sensors , 2002, Analytical and bioanalytical chemistry.

[35]  D. Kolb,et al.  Copper underpotential deposition on ethanethiol-modified Au(111) electrodes : kinetic effects , 1999 .