We apply to the specific case of images taken with the ROSAT PSPC detector our wavelet-based X-ray source detection algorithm presented in a companion paper. Such images are characterized by the presence of detector "ribs," strongly varying point-spread function, and vignetting, so that their analysis provides a challenge for any detection algorithm. First, we apply the algorithm to simulated images of a flat background, as seen with the PSPC, in order to calibrate the number of spurious detections as a function of significance threshold and to ascertain that the spatial distribution of spurious detections is uniform, i.e., unaffected by the ribs; this goal was achieved using the exposure map in the detection procedure. Then, we analyze simulations of PSPC images with a realistic number of point sources; the results are used to determine the efficiency of source detection and the accuracy of output quantities such as source count rate, size, and position, upon a comparison with input source data. It turns out that sources with 10 photons or less may be confidently detected near the image center in medium-length (~104 s), background-limited PSPC exposures. The positions of sources detected near the image center (off-axis angles < 15') are accurate to within a few arcseconds. Output count rates and sizes are in agreement with the input quantities, within a factor of 2 in 90% of the cases. The errors on position, count rate, and size increase with off-axis angle and for detections of lower significance. We have also checked that the upper limits computed with our method are consistent with the count rates of undetected input sources. Finally, we have tested the algorithm by applying it on various actual PSPC images, among the most challenging for automated detection procedures (crowded fields, extended sources, and nonuniform diffuse emission). The performance of our method in these images is satisfactory and outperforms those of other current X-ray detection techniques, such as those employed to produce the MPE and WGA catalogs of PSPC sources, in terms of both detection reliability and efficiency. We have also investigated the theoretical limit for point-source detection, with the result that even sources with only 2-3 photons may be reliably detected using an efficient method in images with sufficiently high resolution and low background.
[1]
D. McCammon,et al.
Analysis prcedures for ROSAT XRT/PSPC observations of extended objects and the diffuse background
,
1994
.
[2]
A. Maggio,et al.
ROSAT PSPC observation of the northeast region of the VELA supernova remnant. 1: Evidence of thermal structure on a scale of 5 min
,
1994
.
[3]
Antonio Maggio,et al.
A Method Based on Wavelet Transforms for Source Detection in Photon-counting Detector Images. I. Theory and General Properties
,
1997
.
[4]
Elmar Pfeffermann,et al.
The Focal Plane Instrumentation Of The ROSAT Telescope
,
1986,
Other Conferences.
[5]
William H. Press,et al.
Numerical recipes in C (2nd ed.): the art of scientific computing
,
1992
.