Evaluation of scatter-to-primary ratio, grid performance and normalized average glandular dose in mammography by Monte Carlo simulation including interference and energy broadening effects

In this work, a computational code for the study of imaging systems and dosimetry in conventional and digital mammography through Monte Carlo simulations is described. The developed code includes interference and Doppler energy broadening for simulation of elastic and inelastic photon scattering, respectively. The code estimates the contribution of scattered radiation to image quality through the spatial distribution of the scatter-to-primary ratio (S/P). It allows the inclusion of different designs of anti-scatter grids (linear or cellular), for evaluation of contrast improvement factor (CIF), Bucky factor (BF) and signal difference-to-noise ratio improvement factor (SIF). It also allows the computation of the normalized average glandular dose, D(g).(N). These quantities were studied for different breast thicknesses and compositions, anode/filter combinations and tube potentials. Results showed that the S/P increases linearly with breast thickness, varying slightly with breast composition or the spectrum used. Evaluation of grid performance showed that the cellular grid provides the highest CIF with smaller BF. The SIF was also greater for the cellular grid, although both grids showed SIF < 1 for thin breasts. Results for D(g).(N) showed that it increases with the half-value layer (HVL) of the spectrum, decreases considerably with breast thickness and has a small dependence on the anode/filter combination. Inclusion of interference effects of breast tissues affected the values of S/P obtained with the grid up to 25%, while the energy broadening effect produced smaller variations on the evaluated quantities.

[1]  J. S. Laughlin,et al.  Absorbed radiation dose in mammography. , 1979, Radiology.

[2]  J A Seibert,et al.  An edge spread technique for measurement of the scatter-to-primary ratio in mammography. , 2000, Medical physics.

[3]  K. Doi,et al.  Radiation dose in diagnostic radiology: Monte Carlo simulation studies. , 1984, Medical physics.

[4]  M H Buonocore,et al.  Monte Carlo validation in diagnostic radiological imaging. , 2000, Medical Physics (Lancaster).

[5]  D R Dance,et al.  X-ray transmission formula for antiscatter grids. , 1983, Physics in medicine and biology.

[6]  A Taibi,et al.  Updating of form factor tabulations for coherent scattering of photons in tissues. , 2002, Physics in medicine and biology.

[7]  T. R. Fewell,et al.  Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. , 1997, Medical physics.

[8]  David J. Hawkes,et al.  X-ray attenuation coefficients of elements and mixtures , 1981 .

[9]  M. Poletti,et al.  X-ray scattering from human breast tissues and breast-equivalent materials. , 2002, Physics in medicine and biology.

[10]  Ann-Katherine Carton,et al.  The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(TI) full-field flat panel detector. , 2009, Medical physics.

[11]  John M Boone,et al.  Grid and slot scan scatter reduction in mammography: comparison by using Monte Carlo techniques. , 2002, Radiology.

[12]  Walter Huda,et al.  Experimental investigation of the dose and image quality characteristics of a digital mammography imaging system. , 2003, Medical physics.

[13]  J. Kosanetzky,et al.  Energy-dispersive X-ray diffraction tomography , 1990 .

[14]  Y. Namito,et al.  Implementation of the Doppler broadening of a Compton-scattered photon into the EGS4 code , 1994 .

[15]  Nico Karssemeijer,et al.  The value of scatter removal by a grid in full field digital mammography. , 2003, Medical physics.

[16]  J. Eichler,et al.  Modelling the elastic scattering in diagnostic radiology: the importance of structure form factors. , 2003, Physics in medicine and biology.

[17]  C. D'Orsi,et al.  Computation of the glandular radiation dose in digital tomosynthesis of the breast. , 2006, Medical physics.

[18]  U Neitzel,et al.  Grids or air gaps for scatter reduction in digital radiography: a model calculation. , 1992, Medical physics.

[19]  G T Barnes,et al.  Contrast and scatter in x-ray imaging. , 1991, Radiographics : a review publication of the Radiological Society of North America, Inc.

[20]  M J Yaffe,et al.  The myth of the 50-50 breast. , 2009, Medical physics.

[21]  Remy Klausz,et al.  Grid removal and impact on population dose in full-field digital mammography. , 2007, Medical physics.

[22]  D R Dance,et al.  A Monte Carlo program for the calculation of contrast, noise and absorbed dose in diagnostic radiology. , 1994, Computer methods and programs in biomedicine.

[23]  Thomas Mertelmeier,et al.  X-ray spectrum optimization of full-field digital mammography: simulation and phantom study. , 2006, Medical physics.

[24]  K. Doi,et al.  Some properties of photon scattering in water phantoms in diagnostic radiology. , 1986, Medical physics.

[25]  J. Boone,et al.  Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment. , 1999, Radiology.

[26]  L. Morin Molecular Form Factors and Photon Coherent Scattering Cross Sections of Water , 1982 .

[27]  A Tomal,et al.  Evaluation of subject contrast and normalized average glandular dose by semi-analytical models. , 2010, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[28]  K Doi,et al.  Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies. , 1985, Medical physics.

[29]  D E Peplow,et al.  Measured molecular coherent scattering form factors of animal tissues, plastics and human breast tissue. , 1998, Physics in medicine and biology.

[30]  J. H. Hubbell,et al.  Atomic form factors, incoherent scattering functions, and photon scattering cross sections , 1975 .

[31]  Ehsan Samei,et al.  A framework for optimising the radiographic technique in digital X-ray imaging. , 2005, Radiation protection dosimetry.

[32]  M Souto,et al.  Scatter in computed radiography. , 1993, Radiology.

[33]  José M. Fernández-Varea,et al.  FAST SAMPLING ALGORITHM FOR THE SIMULATION OF PHOTON COMPTON SCATTERING , 1996 .

[34]  D R Dance,et al.  The computation of scatter in mammography by Monte Carlo methods. , 1984, Physics in medicine and biology.

[35]  H Bernstein,et al.  Experimental and theoretical energy and angular dependencies of scattered radiation in the mammography energy range. , 1983, Medical physics.

[36]  R. Gordon,et al.  A method for 3D electron density imaging using single scattered x-rays with application to mammographic screening , 2008, Physics in medicine and biology.

[37]  R D Speller,et al.  Correlation of energy dispersive diffraction signatures and microCT of small breast tissue samples with pathological analysis , 2007, Physics in medicine and biology.

[38]  Dev P. Chakraborty The effect of the antiscatter grid on full-field digital mammography phantom images , 2009, Journal of Digital Imaging.

[39]  R. H. Pratt,et al.  An overview of the theories used in compton scattering calculations , 1997 .

[40]  Douglas Rayner Hartree,et al.  On the Intensity of Total Scattering of X-Rays , 1929 .

[41]  D. Dance Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose. , 1990, Physics in medicine and biology.

[42]  Carl J. D'Orsi,et al.  Glandular radiation dose in tomosynthesis of the breast using tungsten targets , 2008, Journal of applied clinical medical physics.

[43]  D E Raeside,et al.  Monte Carlo principles and applications. , 1976, Physics in medicine and biology.

[44]  D R Dance,et al.  Calculation of dose and contrast for two mammographic grids. , 1992, Physics in medicine and biology.

[45]  W. Veldkamp,et al.  Glandularity and mean glandular dose determined for individual women at four regional breast cancer screening units in The Netherlands , 2006, Physics in medicine and biology.

[46]  M. Säbel,et al.  Recent developments in breast imaging. , 1996, Physics in medicine and biology.

[47]  Kenneth A Fetterly,et al.  Experimental evaluation of fiber-interspaced antiscatter grids for large patient imaging with digital x-ray systems , 2007, Physics in medicine and biology.

[48]  Frank Herbert Attix,et al.  Introduction to Radiological Physics and Radiation Dosimetry: Attix/Introduction , 2007 .

[49]  Gary J. Royle,et al.  A Monte Carlo simulation study to investigate the potential of diffraction enhanced breast imaging , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[50]  R. Speller Tissue analysis using X-ray scattering , 1999 .

[51]  J Persliden,et al.  Scatter rejection by air gaps in diagnostic radiology. Calculations using a Monte Carlo collision density method and consideration of molecular interference in coherent scattering. , 1997, Physics in medicine and biology.

[52]  Johannes Zoetelief,et al.  Calculation of Air Kerma to Average Glandular Tissue Dose Conversion Factors for Mammography , 1995 .

[53]  J. B. Mann,et al.  Hartree-Fock Compton profiles for the elements , 1975 .

[54]  O. Gonçalves,et al.  Precise evaluation of elastic differential scattering cross-sections and their uncertainties in X-ray scattering experiments , 2002 .

[55]  K Doi,et al.  The validity of Monte Carlo simulation in studies of scattered radiation in diagnostic radiology. , 1983, Physics in medicine and biology.

[56]  G. Barnes,et al.  Normalized average glandular dose in molybdenum target-rhodium filter and rhodium target-rhodium filter mammography. , 1994, Radiology.

[57]  P. C. Johns,et al.  Optimum momentum transfer arguments for x-ray forward scatter imaging. , 2002, Medical physics.

[58]  J. Boone,et al.  Scatter/primary in mammography: comprehensive results. , 2000, Medical physics.

[59]  G T Barnes,et al.  Mammography grid performance. , 1999, Radiology.

[60]  C. J. Kotre,et al.  Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. , 2000, Physics in medicine and biology.

[61]  Idris Elbakri,et al.  Effect of scatter and an antiscatter grid on the performance of a slot-scanning digital mammography system. , 2006, Medical physics.

[62]  O. Gonçalves,et al.  Evaluation of the influence of scattering profiles on the resolution, scatter/primary ratio, and grid performance in mammography , 2001 .

[63]  G. A. Carlsson,et al.  Generalised use of contrast degradation and contrast improvement factors in diagnostic radiology. Application to vanishing contrast. , 1986, Physics in medicine and biology.

[64]  D. Dance,et al.  Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocols , 2009, Physics in medicine and biology.

[65]  R D Speller,et al.  X-ray scatter signatures for normal and neoplastic breast tissues. , 1999, Physics in medicine and biology.

[66]  C. D'Orsi,et al.  Scatter radiation in digital tomosynthesis of the breast. , 2007, Medical physics.

[67]  S. Webb,et al.  Rayleigh scatter in kilovoltage x-ray imaging: is the independent atom approximation good enough? , 2009, Physics in medicine and biology.

[68]  L Costaridou,et al.  Monte Carlo generated conversion factors for the estimation of average glandular dose in contact and magnification mammography , 2006, Physics in medicine and biology.

[69]  Samuli Siltanen,et al.  X-ray scattering in full-field digital mammography. , 2003, Medical physics.

[70]  S L Fritz,et al.  Scatter/primary ratios for x-ray spectra modified to enhance iodine contrast in screen-film mammography. , 1983, Medical physics.

[71]  Roland Ribberfors,et al.  Relationship of the relativistic Compton cross section to the momentum distribution of bound electron states , 1975 .

[72]  J. Boone,et al.  The effect of skin thickness determined using breast CT on mammographic dosimetry. , 2008, Medical physics.

[73]  I A Brezovich,et al.  The intensity of scattered radiation in mammography. , 1978, Radiology.

[74]  K. Berggren,et al.  Incoherent-x-ray-scattering functions and cross sections ( d σ d Ω ′ ) incoh by means of a pocket calculator , 1982 .

[75]  G. Barnes,et al.  Spectral dependence of glandular tissue dose in screen-film mammography. , 1991, Radiology.