Smoking detection based on regularity analysis of hand to mouth gestures

A number of studies have been introduced for the detection of smoking via a variety of features extracted from the wrist IMU data. However, none of the previous studies investigated gesture regularity as a way to detect smoking events. This study describes a novel method to detect smoking events by monitoring the regularity of hand gestures. Here, the regularity of hand gestures was estimated from a one axis accelerometer worn on the wrist of the dominant hand. To quantify the regularity score, this paper applied a novel approach of unbiased autocorrelation to process the temporal sequence of hand gestures. The comparison of regularity score of smoking events with other activities substantiated that hand-to-mouth gestures are highly regular during smoking events and have the potential to detect smoking from among a plethora of daily activities. This hypothesis was validated on a dataset of 140 cigarette smoking events generated by 35 regular smokers in a controlled setting. The regularity of gestures detected smoking events with an F1-score of 0.81. However, the accuracy dropped to 0.49 in the free-living study of same 35 smokers smoking 295 cigarettes. Nevertheless, regularity of gestures may be useful as a supportive tool for other detection methods. To validate that proposition, this paper further incorporated the regularity of gestures in an instrumented lighter based smoking detection algorithm and achieved an improvement in F1-score from 0.89 (lighter only) to 0.91 (lighter and regularity of hand gestures).

[1]  Dario Pompili,et al.  Erratum to: Human motion recognition using a wireless sensor-based wearable system , 2011, Personal and Ubiquitous Computing.

[2]  Jun-Ming Lu,et al.  Real-Time Gait Cycle Parameter Recognition Using a Wearable Accelerometry System , 2011, Sensors.

[3]  Stephen S. Intille,et al.  Automated detection of puffing and smoking with wrist accelerometers , 2014, PervasiveHealth.

[4]  Raul I. Ramos-Garcia,et al.  Development of a Multisensory Wearable System for Monitoring Cigarette Smoking Behavior in Free-Living Conditions , 2017, Electronics.

[5]  S. Glantz,et al.  E-cigarettes and smoking cessation in real-world and clinical settings: a systematic review and meta-analysis. , 2016, The Lancet. Respiratory medicine.

[6]  Rajesh Nandy,et al.  Efficacy of SMS Text Message Interventions for Smoking Cessation: A Meta-Analysis. , 2015, Journal of substance abuse treatment.

[7]  Harriët Wittink,et al.  Accuracy of estimates of step frequency from a wearable gait monitor , 2015 .

[8]  Philipp Scholl,et al.  When do you light a fire?: capturing tobacco use with situated, wearable sensors , 2013, UbiComp.

[9]  B. Lushniak,et al.  The Health consequences of smoking—50 years of progress : a report of the Surgeon General , 2014 .

[10]  Laura Rocchi,et al.  Recommended number of strides for automatic assessment of gait symmetry and regularity in above-knee amputees by means of accelerometry and autocorrelation analysis , 2012, Journal of NeuroEngineering and Rehabilitation.

[11]  W F Velicer,et al.  Assessing outcome in smoking cessation studies. , 1992, Psychological bulletin.

[12]  Paul J. M. Havinga,et al.  A hierarchical lazy smoking detection algorithm using smartwatch sensors , 2016, 2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom).

[13]  W. Riley,et al.  College Smoking-Cessation Using Cell Phone Text Messaging , 2004, Journal of American college health : J of ACH.

[14]  Xin Xu,et al.  Annual healthcare spending attributable to cigarette smoking: an update. , 2015, American journal of preventive medicine.

[15]  Evangelos Kalogerakis,et al.  RisQ: recognizing smoking gestures with inertial sensors on a wristband , 2014, MobiSys.

[16]  Jorunn L Helbostad,et al.  Estimation of gait cycle characteristics by trunk accelerometry. , 2004, Journal of biomechanics.

[17]  T. Hadjistavropoulos,et al.  Evaluation of age-related differences in the stride-to-stride fluctuations, regularity and symmetry of gait using a waist-mounted tri-axial accelerometer. , 2014, Gait & posture.

[18]  Dario Pompili,et al.  Laboratory Validation of Inertial Body Sensors to Detect Cigarette Smoking Arm Movements , 2014, Electronics.