A Current Distortion Compensation Scheme for Four-Switch Inverters

The four-switch inverter, having a lower number of insulated gate bipolar transistors(IGBTs), has been studied for the possibility of reducing the inverter cost. But it has a limited performance in the low-frequency region, because the balance among the phase currents collapses due to the fluctuation of the center tap voltage of the DC-link capacitors. This problem could be solved if the DC-link capacitance is infinitely large, but it is a costly solution. In this paper, this problem is looked at from the perspective of source impedance and the voltage variation caused by the current flow through the capacitors. The source impedance of the center tap is large compared with other normal IGBT arms. This causes an asymmetry among the three voltage sources, resulting in phase current distortion and unbalance. Second, the capacitor voltage change caused by current flow is another source of current distortion and unbalance. The voltage errors are derived, and based on them, a compensation method is proposed. Effectiveness of the proposed method is demonstrated by the simulation and experimental results.

[1]  T. S. Radwan,et al.  Fuzzy logic controller based cost effective 4-switch, 3-phase inverter fed IPM synchronous motor drive system , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[2]  J. Klima Analytical Investigation of an Induction Motor Fed From Four-Switch VSI With a New Space Vector Modulation Strategy , 2006, IEEE Transactions on Energy Conversion.

[3]  M.N. Uddin,et al.  Fuzzy-logic-controller-based cost-effective four-switch three-phase inverter-fed IPM synchronous motor drive system , 2006, IEEE Transactions on Industry Applications.

[4]  Jacobus Daniel van Wyk,et al.  A Comparative Investigation of a Three-Phase Induction Machine Drive with a Component Minimized Voltage-Fed Inverter under Different Control Options , 1984 .

[5]  Jaehong Kim,et al.  Two arm inverter with three level boost converter for three phase induction motors , 2008, 2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition.

[6]  H. van der Broeck,et al.  Analytical analysis of the harmonic effects of a PWM AC drive , 1988 .

[7]  Thomas A. Lipo,et al.  VSI-PWM rectifier/inverter system with a reduced switch count , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[8]  A.M.S. Mendes,et al.  Thermal Performance of a Three-Phase Induction Motor Under Fault Tolerant Operating Strategies , 2008, IEEE Transactions on Power Electronics.

[9]  C.B. Jacobina,et al.  Reduced Switch Count Multiple Three-Phase AC Machine Drive Systems , 2008, IEEE Transactions on Power Electronics.

[10]  A.M.N. Lima,et al.  Induction motor drive system for low power applications , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[11]  F. Blaabjerg,et al.  Reconstruction of output currents and fault detection in a B4-inverter with only one current sensor , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[12]  Grant A. Covic,et al.  Eliminating output distortion in four-switch inverters with three-phase loads , 1998 .

[13]  Grant A. Covic,et al.  DC link imbalance compensation in four-switch inverter AC motor drives , 1997 .

[14]  Jiang Li,et al.  Flux vector modulation strategy for a four-switch three-phase inverter for motor drive applications , 1997, PESC97. Record 28th Annual IEEE Power Electronics Specialists Conference. Formerly Power Conditioning Specialists Conference 1970-71. Power Processing and Electronic Specialists Conference 1972.

[15]  Chung-Wen Hung,et al.  Position Sensorless Control for Four-Switch Three-Phase Brushless DC Motor Drives , 2008, IEEE Transactions on Power Electronics.

[16]  P. Enjeti,et al.  A new single phase to three phase converter with active input current shaping for low cost AC motor drives , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[17]  Haoran Zhang,et al.  A reduced switch dual-bridge inverter topology for the mitigation of bearing currents, EMI and DC-link voltage variations , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[18]  J. T. Boys,et al.  An improved single phase to three phase converter for low cost AC motor drives , 1995, Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95.

[19]  Prasad Enjeti,et al.  Economic single-phase to three-phase converter topologies for fixed and variable frequency output , 1993 .

[20]  Frede Blaabjerg,et al.  Adaptive SVM to compensate DC-link voltage ripple for four-switch three-phase voltage-source inverters , 1999 .

[21]  Mehrdad Ehsani,et al.  On the feasibility of four-switch three-phase BLDC motor drives for low cost commercial applications: topology and control , 2003 .

[22]  C.B. Jacobina,et al.  A General PWM Strategy for Four-Switch Three-Phase Inverters , 2006, IEEE Transactions on Power Electronics.

[23]  Frede Blaabjerg,et al.  A new optimized space vector modulation strategy for a component minimized voltage source inverter , 1995, Proceedings of 1995 IEEE Applied Power Electronics Conference and Exposition - APEC'95.

[24]  Dan Sun,et al.  Four-Switch Inverter Fed PMSM DTC with SVM approach for Fault Tolerant operation , 2007, 2007 IEEE International Electric Machines & Drives Conference.