Intensity modulated conformal therapy for intracranial lesions.

The Peacock planning and delivery system was used to create treatment plans and deliver these plans to patients. The system involves an arc therapy delivery of small (2 cm long) slices of radiation combined with indexing of the couch to achieve target coverage. Two clinical examples are shown to demonstrate the system's capability and evaluate the resources required to produce and deliver the plans. One plan is an optic sheath meningioma and the other is a craniopharyngioma that surrounded the optic chiasm. The optic sheath meningioma was treated to 50 Gy in 25 fractions. The treatment involved delivery of two arcs. The total time to set up the patient and deliver the treatment was less than 15 min. Planning and plan validation after computed tomography required approximately 3 days. The patient had 100% restoration of her field of vision and is stable 3 years post therapy. The second patient is a 9-year-old who had a craniopharyngioma which surrounded the optic chiasm. The tumor was treated to 50.4 Gy in 28 fractions and the dose to the optic chiasm was limited to 45 Gy. The treatment required three arcs and total treatment time was less than 20 min. The patient is stable 15 months post therapy. The system is able to create and deliver radiation patterns that are unique. These plans can be created and delivered in times that rival conventional forward planning conformal radiotherapy systems that cannot produce or conveniently deliver such plans.

[1]  E. B. Butler,et al.  A comparison of intensity modulated conformal therapy with a conventional external beam stereotactic radiosurgery system for the treatment of single and multiple intracranial lesions. , 1996, International journal of radiation oncology, biology, physics.

[2]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[3]  S. Webb Optimization by simulated annealing of three-dimensional conformal treatment planning for radiation fields defined by a multileaf collimator. , 1991, Physics in medicine and biology.

[4]  T. Bortfeld,et al.  X-ray field compensation with multileaf collimators. , 1994, International journal of radiation oncology, biology, physics.

[5]  Comment on "Reporting and analyzing dose distributions: a concept of equivalent uniform dose" [Med. Phys. 24, 103-109 (1997)]. , 1997, Medical physics.

[6]  S. Spirou,et al.  Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators. , 1994, Medical physics.

[7]  D. Convery,et al.  The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation , 1992 .

[8]  Cedric X. Yu,et al.  Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. , 1995, Physics in medicine and biology.

[9]  S Takahashi,et al.  Conformation radiotherapy. Rotation techniques as applied to radiography and radiotherapy of cancer. , 1965, Acta radiologica: diagnosis.

[10]  A Brahme,et al.  Shaping of arbitrary dose distributions by dynamic multileaf collimation. , 1988, Physics in medicine and biology.

[11]  S. Webb Optimisation of conformal radiotherapy dose distributions by simulated annealing. , 1989, Physics in medicine and biology.

[12]  A R Bleier,et al.  The field-matching problem as it applies to the peacock three dimensional conformal system for intensity modulation. , 1996, International journal of radiation oncology, biology, physics.

[13]  C. D. Gelatt,et al.  Optimization by Simulated Annealing , 1983, Science.

[14]  A. Niemierko Reporting and analyzing dose distributions: a concept of equivalent uniform dose. , 1997, Medical physics.

[15]  W. Hoyt,et al.  Precision radiation therapy for optic nerve sheath meningiomas. , 1992, International journal of radiation oncology, biology, physics.

[16]  Mark P. Carol,et al.  Peacock™: A system for planning and rotational delivery of intensity‐modulated fields , 1995, Int. J. Imaging Syst. Technol..

[17]  E. B. Butler,et al.  Improvement in Visual Function in an Eye with a Presumed Optic Nerve Sheath Meningioma after Treatment with Three‐Dimensional Conformal Radiation Therapy , 1996, Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society.