Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography

Dual-energy CT can be applied for bone elimination in cerebral CT angiography (CTA). The aim of this study was to compare the results of dual-energy direct bone removal CTA (DE-BR-CTA) with those of digital subtraction angiography (DSA). Twelve patients with intracranial aneurysms and/or ICA stenosis underwent a dual-source CT in dual-energy mode. Post-processing software selectively removed bone structures using the two energy data sets. Three-dimensional images with and without bone removal were reviewed and compared to DSA. Dual-energy bone removal was successful in all patients. For 10 patients, bone removal was good and CTA maximum-intensity projection (MIP) images could be used for vessel evaluation. For two patients, bone removal was moderate with some bone remnants, but this did not inhibit the three-dimensional visualization. Three aneurysms adjacent to the skull base were only partially visible in conventional CTA but were fully visible in DE-BR-CTA. In five patients with ICA stenosis, DE-BR-CTA revealed the stenotic lesions on the MIP images. The correlation between DSA and DE-BR-CTA was good (R2=0.822), but DE-BR-CTA led to an overestimation of stenosis. DE-BR-CTA was able to eliminate bone structure using only a single CT data acquisition and is useful to evaluate intracranial aneurysms and stenosis.

[1]  Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: comparison with digital subtraction angiography. , 2008, European journal of radiology.

[2]  M. Reiser,et al.  Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience , 2008, Investigative radiology.

[3]  T. Sakaki,et al.  Use of spiral computerized tomography angiography in patients with subarachnoid hemorrhage in whom subtraction angiography did not reveal cerebral aneurysms. , 2000, Journal of neurosurgery.

[4]  W. Bautz,et al.  Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging , 2006, European Radiology.

[5]  Preoperative evaluation of intracranial aneurysms: usefulness of intraarterial 3D CT angiography and conventional angiography with a combined unit--initial experience. , 2001, Radiology.

[6]  M. Reiser,et al.  Material differentiation by dual energy CT: initial experience , 2007, European Radiology.

[7]  A. Malek,et al.  Fusion of Three-dimensional Calcium Rendering with Rotational Angiography to Guide the Treatment of a Giant Intracranial Aneurysm: Technical Case Report , 2006, Neurosurgery.

[8]  R. Agid,et al.  Acute subarachnoid hemorrhage: using 64-slice multidetector CT angiography to “triage” patients’ treatment , 2006, Neuroradiology.

[9]  H. A. Smith,et al.  A standardized method for measuring intracranial arterial stenosis. , 2000, AJNR. American journal of neuroradiology.

[10]  Cheng Liu,et al.  An initial qualitative study of dual-energy CT in the knee ligaments , 2008, Surgical and Radiologic Anatomy.

[11]  H. Venema,et al.  CT angiography of the circle of Willis and intracranial internal carotid arteries: maximum intensity projection with matched mask bone elimination-feasibility study. , 2001, Radiology.

[12]  E. Vittinghoff,et al.  How Accurate Is CT Angiography in Evaluating Intracranial Atherosclerotic Disease? , 2008, Stroke.

[13]  Borut Marincek,et al.  Dual-Energy Contrast-Enhanced Computed Tomography for the Detection of Urinary Stone Disease , 2007, Investigative radiology.

[14]  G. Duckwiler,et al.  Intracranial vascular stenosis and occlusive disease: evaluation with CT angiography, MR angiography, and digital subtraction angiography. , 2005, AJNR. American journal of neuroradiology.

[15]  P. Joseph,et al.  Noise considerations in dual energy CT scanning. , 1979, Medical physics.

[16]  G. Chiro,et al.  Tissue signatures with dual-energy computed tomography. , 1979, Radiology.

[17]  W D McDavid,et al.  Extraction of information from CT scans at different energies. , 1979, Medical physics.

[18]  K Arita,et al.  Subtracted 3D CT angiography for evaluation of internal carotid artery aneurysms: comparison with conventional digital subtraction angiography. , 2006, AJNR. American journal of neuroradiology.

[19]  K. Heimberger,et al.  Spiral CT Angiography with Digital Subtraction of Extra‐ and Intracranial Vessels , 1994, Journal of computer assisted tomography.

[20]  E Klotz,et al.  Bone-subtraction Ct Angiography for the Evaluation of Intracranial Aneurysms Materials and Methods , 2004 .

[21]  James C. Williams,et al.  Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. , 2007, Academic radiology.

[22]  H. Genant,et al.  Quantitative bone mineral analysis using dual energy computed tomography. , 1977, Investigative radiology.

[23]  M. Reiser,et al.  Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience , 2008, Investigative radiology.

[24]  C. Cann,et al.  A Postprocessing Dual Energy Technique for Vertebral CT Densitometry , 1984, Journal of computer assisted tomography.

[25]  A. McMahon,et al.  Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience. , 2003, AJNR. American journal of neuroradiology.