A disposable amperometric immunosensor for 2,4-dichlorophenoxyacetic acid

Abstract A disposable immunochemical biosensor for the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) was developed using a screen-printed electrode system as an amperometric transducer and monoclonal antibodies against 2,4-D as a biospecific part. At first, the electrochemical system for determination of peroxidase activity was studied. For measurements, the peroxidase substrates were hydrogen peroxide together with either hydroquinone, 1,2-phenylenediamine or pyrocatechol as electron donors, which were amperometrically detected using platinum, gold and graphite composite layers as working electrode materials. The optimal concentrations of reaction components were found, the highest signals being achieved for hydroquinone with gold or graphite electrodes. The immunochemical system makes use of the competitive assay principle with 2,4-D covalently immobilized either directly on the surface of the gold electrode or on a separate nylon membrane. The peroxidase-antibody conjugate was synthesized and used as a tracing reagent. By using 2,4-D immobilized through its carboxylic group directly to the silanized surface of the gold working electrode, a detection limit close to 0.1 μg/1 of free 2,4-D was achieved. One analysis was completed in 1 h (30 min for the immunochemical reaction, washing, 25 min incubation with substrate, measurement).

[1]  G G Guilbault,et al.  A piezoelectric immunobiosensor for atrazine in drinking water. , 1992, Biosensors & bioelectronics.

[2]  J. Hall,et al.  Immunoassays for the detection of 2,4-D and picloram in river water and urine , 1989 .

[3]  Kim R. Rogers,et al.  A fiber-optic immunosensor for detecting parathion , 1992 .

[4]  Bruce D. Hammock,et al.  Use of Immunochemical Techniques for the Analysis of Pesticides , 1989 .

[5]  Rolf D. Schmid,et al.  Real time analysis of competitive binding using grating coupler immunosensors for pesticide detection , 1994 .

[6]  M. Mascini,et al.  Enzyme electrodes with improved mechanical and analytical characteristics obtained by binding enzymes to nylon nets , 1983 .

[7]  J. Fleeker,et al.  A radioimmunoassay to screen for 2,4-dichlorophenoxyacetic acid and 2,4,5-trichlorophenoxyacetic acid in surface water , 1981, Bulletin of environmental contamination and toxicology.

[8]  R. Schmid,et al.  Flow injection immunoanalysis (FIIA)--a new immunoassay format for the determination of pesticides in water. , 1991, Biosensors & bioelectronics.

[9]  Steven L. Petersen,et al.  Composite electrodes for electroanalysis: Principles and applications , 1990 .

[10]  Vladimir Kolar,et al.  Monoclonal Elisa for 2,4-Dichlorophenoxyacetic Acid: Characterization of Antibodies and Assay Optimization , 1994 .

[11]  T. Giersch A new monoclonal antibody for the sensitive detection of atrazine with immunoassay in microtiter plate and dipstick format , 1993 .

[12]  Maria Minunni,et al.  A Piezoelectric Quartz Crystal Biosensor as a Direct Affinity Sensor , 1994 .

[13]  J. Sherry,et al.  Environmental Chemistry: The Immunoassay Option , 1992 .

[14]  M. Mascini,et al.  Characterization of monoclonal antibodies to 2,4-dichlorophenoxyacetic acid using a piezoelectric quartz crystal microbalance in solution. , 1994, Journal of immunological methods.

[15]  Maria Minunni,et al.  Detection of Pesticide in Drinking Water Using Real-Time Biospecific Interaction Analysis (BIA) , 1993 .

[16]  B. Hock,et al.  Development of an ELISA for the analysis of atrazine metabolites deethylatrazine and deisopropylatrazine , 1991 .

[17]  M. L. Richardson Chemistry, agriculture and the environment. , 1991 .

[18]  A. Egorov,et al.  Immunoaffinity chromatographic method for the detection of pesticides , 1993 .