Stochastic Multiperiod OPF Model of Power Systems With HVDC-Connected Intermittent Wind Power Generation

This paper presents a new model for a stochastic multiperiod optimal power-flow (SMP-OPF) problem which includes an offshore wind farm connected to the grid by a line-commutated converter high-voltage dc link. The offshore wind farm is composed of doubly fed induction generators (DFIGs), and the DFIG's capability curve is considered in order to obtain a more realistic dispatch for wind farms. The uncertainties of wind power generation are also taken into account using a scenario-based approach which can be adopted by the system operator to obtain the optimal active and reactive power schedules for thermal and wind power generation units. To illustrate the effectiveness of the proposed approach, it is applied on the IEEE 118-bus test system. The obtained results demonstrate the capability of the proposed SMP-OPF model for the determination of the optimal operation of power systems.

[1]  D. Santos-Martin,et al.  Reactive power capability of doubly fed asynchronous generators , 2008 .

[2]  David Kendrick,et al.  GAMS, a user's guide , 1988, SGNM.

[3]  A. Conejo,et al.  Scenario Reduction for Futures Market Trading in Electricity Markets , 2009, IEEE Transactions on Power Systems.

[4]  Kai Heussen,et al.  Unified System-Level Modeling of Intermittent Renewable Energy Sources and Energy Storage for Power System Operation , 2012, IEEE Systems Journal.

[5]  P. Kundur,et al.  Power system stability and control , 1994 .

[6]  Bikash C. Pal,et al.  Intermittent wind generation in optimal power flow dispatching , 2009 .

[7]  R D Zimmerman,et al.  MATPOWER: Steady-State Operations, Planning, and Analysis Tools for Power Systems Research and Education , 2011, IEEE Transactions on Power Systems.

[8]  Kjell Eriksson Operational experience of HVDC light , 2001 .

[9]  Abbas Rabiee,et al.  Time-varying acceleration coefficients IPSO for solving dynamic economic dispatch with non-smooth cost function , 2012 .

[10]  Antonio J. Conejo,et al.  Multiperiod optimal power flow using Benders decomposition , 2000 .

[11]  Alireza Soroudi,et al.  Probabilistic determination of pilot points for zonal voltage control , 2012 .

[12]  Chen Wang,et al.  Optimal Power Flow Solution Incorporating Wind Power , 2012, IEEE Systems Journal.

[13]  Xian Liu,et al.  Economic Load Dispatch Constrained by Wind Power Availability: A Wait-and-See Approach , 2010, IEEE Transactions on Smart Grid.

[14]  G. Andersson,et al.  Influence of Hydro Units' Generator-to-Turbine Inertia Ratio on Damping of Subsynchronous Oscillations , 1984 .

[15]  Alireza Soroudi,et al.  Binary PSO-based dynamic multi-objective model for distributed generation planning under uncertainty , 2012 .

[16]  Ehab F. El-Saadany,et al.  Probabilistic approach for optimal allocation of wind-based distributed generation in distribution systems , 2011 .

[17]  James F. Manwell,et al.  TRANSMISSION OPTIONS FOR OFFSHORE WIND FARMS IN THE UNITED STATES , 2002 .

[18]  G. Andersson,et al.  Power stability analysis of multi-infeed HVDC systems , 1998 .

[19]  R. Torres-Olguin,et al.  Offshore Wind Farm Grid Integration by VSC Technology With LCC-Based HVDC Transmission , 2012, IEEE Transactions on Sustainable Energy.

[20]  A. Soroudi,et al.  Possibilistic-Scenario Model for DG Impact Assessment on Distribution Networks in an Uncertain Environment , 2012, IEEE Transactions on Power Systems.

[21]  Neville R. Watson,et al.  Flexible power transmission--the HVDC options , 2007 .

[22]  D. Santos-Martin,et al.  Optimal reactive power allocation in an offshore wind farms with LCC-HVdc link connection , 2012 .

[23]  Mukund R. Patel Wind and Solar Power Systems: Design, Analysis, and Operation, Second Edition , 2005 .

[24]  R. Feuillet,et al.  System protection scheme for mitigation of cascaded voltage collapses , 2009 .

[25]  M. Stiebler Wind Energy Systems for Electric Power Generation , 2008 .

[26]  Santiago Arnaltes,et al.  Optimal Operation of Offshore Wind Farms With Line-Commutated HVDC Link Connection , 2010, IEEE Transactions on Energy Conversion.

[27]  G. Andersson,et al.  Analysis of HVDC converters connected to weak AC systems , 1990 .

[28]  Arne Stolbjerg Drud,et al.  CONOPT - A Large-Scale GRG Code , 1994, INFORMS J. Comput..

[29]  B. Venkatesh,et al.  A Practical Real-Time OPF Method Using New Triangular Approximate Model of Wind Electric Generators , 2012, IEEE Transactions on Power Systems.

[30]  P. Rodriguez,et al.  Wind Farm Grid Integration Using VSC Based HVDC Transmission - An Overview , 2008, 2008 IEEE Energy 2030 Conference.

[31]  Nasser Sadati,et al.  An enhanced under-voltage load-shedding scheme to provide voltage stability , 2007 .

[32]  Abbas Rabiee,et al.  Voltage security constrained multi-period optimal reactive power flow using benders and optimality condition decompositions , 2013, IEEE Transactions on Power Systems.

[33]  J. X. Ostolaza,et al.  Reactive power control of wind farms for voltage control applications , 2004 .