Quantitative analysis of sialic acid on erythrocyte membranes using a photothermal biosensor.

The quantitative analysis of sialic acid (SA) at an erythrocyte membrane is becoming an important clinical parameter in diagnosing cancer and diabetes. In spite of such clinical importance, there are only a few, very expensive, time consuming and complicated quantifying methods established. To solve this problem, we demonstrate a novel and direct measurement technique for SA exposed to the cell membrane using a photothermal biosensing system in which the hemoglobin molecules in the erythrocyte absorb a specific wavelength of photons (532 nm) and convert it to a temperature change. For measuring the quantity of SA, we first modified the sensor surface of a micro-scaled thermometer using phenylboronic acid (PBA) containing a self-assembled monolayer (SAM) to capture the SA-expressing erythrocytes. Second, the sensor surface was thoroughly washed, and when more SA was expressed, tighter association of erythrocytes to the biosensor was expected. Thirdly, blood sample changes in temperature, heated by the 532 nm wavelength laser, were measured by the bottom layer's micron sized platinum thermometer. The temperature changes from the erythrocytes captured on the sensor surface could be estimated by the amount of SA expressed on the erythrocyte membrane. This novel SA analysis system can solve the problems raised by conventional methods such as multiple enzyme reactions and a time consuming process. We expect that this system will help provide a new tool in the quantitative analysis of SA expression level for the diagnosis of diabetes and cancers.

[1]  Hyung Hee Cho,et al.  Direct measurement of the in vitro hemoglobin content of erythrocytes using the photo-thermal effect of the heme group. , 2010, The Analyst.

[2]  V. Haldankar,et al.  RBC membrane composition in insulin dependent diabetes mellitus in context of oxidative stress , 2008, Indian Journal of Clinical Biochemistry.

[3]  Dmitri O. Lapotko,et al.  Laser-induced micro-bubbles in cells , 2005 .

[4]  C. Cairo,et al.  Detection of cellular sialic acid content using nitrobenzoxadiazole carbonyl-reactive chromophores. , 2012, Bioconjugate chemistry.

[5]  Joop A. Peters,et al.  Towards targeted MRI: new MRI contrast agents for sialic acid detection. , 2004, Chemistry.

[6]  Akira Matsumoto,et al.  Noninvasive sialic acid detection at cell membrane by using phenylboronic acid modified self-assembled monolayer gold electrode. , 2009, Journal of the American Chemical Society.

[7]  A. Passaniti,et al.  Cell surface sialylation and tumor metastasis. Metastatic potential of B16 melanoma variants correlates with their relative numbers of specific penultimate oligosaccharide structures. , 1988, The Journal of biological chemistry.

[8]  L. Mazzanti,et al.  Sialic acid content in erythrocyte membranes from pregnant women affected by gestational diabetes. , 2002, Metabolism: clinical and experimental.

[9]  T. Takeuchi,et al.  Surface plasmon resonance sensor using molecularly imprinted polymer for detection of sialic acid. , 2001, Biosensors & bioelectronics.

[10]  Teruo Okano,et al.  Anomalous binding profile of phenylboronic acid with N-acetylneuraminic acid (Neu5Ac) in aqueous solution with varying pH. , 2003, Journal of the American Chemical Society.

[11]  Darryl P Almond,et al.  Photothermal science and techniques , 1996 .

[12]  D. Lapotko,et al.  Laser‐induced bubbles in living cells , 2006, Lasers in surgery and medicine.

[13]  Hyo-Il Jung,et al.  An integrated photo-thermal sensing system for rapid and direct diagnosis of anemia. , 2010, Biosensors & bioelectronics.

[14]  Roland Schauer,et al.  Achievements and challenges of sialic acid research , 2000, Glycoconjugate Journal.

[15]  A. Imbard,et al.  Measurement of free and total sialic acid by isotopic dilution liquid chromatography tandem mass spectrometry method. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[16]  R.R. Anderson,et al.  Selective photothermolysis: precise microsurgery by selective absorption of pulsed radiation. , 1983, Science.

[17]  L. Mazzanti,et al.  Sialic acid, diabetes, and aging: a study on the erythrocyte membrane. , 1997, Metabolism: clinical and experimental.