Cooperative dry-electrode sensors for multi-lead biopotential and bioimpedance monitoring.

Cooperative sensors is a novel measurement architecture that allows the acquiring of biopotential signals on patients in a comfortable and easy-to-integrate manner. The novel sensors are defined as cooperative in the sense that at least two of them work in concert to measure a target physiological signal, such as a multi-lead electrocardiogram or a thoracic bioimpedance.This paper starts by analysing the state-of-the-art methods to simultaneously measure biopotential and bioimpedance signals, and justifies why currently (1) passive electrodes require the use of shielded or double-shielded cables, and (2) active electrodes require the use of multi-wired cabled technologies, when aiming at high quality physiological measurements.In order to overcome the limitations of the state-of-the-art, a new method for biopotential and bioimpedance measurement using the cooperative sensor is then presented. The novel architecture allows the acquisition of the aforementioned biosignals without the need of shielded or multi-wire cables by splitting the electronics into separate electronic sensors comprising each of two electrodes, one for voltage measurement and one for current injection. The sensors are directly in contact with the skin and connected together by only one unshielded wire. This new configuration requires one power supply per sensor and all sensors need to be synchronized together to allow them to work in concert.After presenting the working principle of the cooperative sensor architecture, this paper reports first experimental results on the use of the technology when applied to measuring multi-lead ECG signals on patients. Measurements performed on a healthy patient demonstrate the feasibility of using this novel cooperative sensor architecture to measure biopotential signals and compliance with common mode rejection specification accordingly to international standard (IEC 60601-2-47) has also been assessed.By reducing the need of using complex wiring setups, and by eliminating the presence of central recording devices (cooperative sensors directly sense and store the measured biosignals on the site), the depicted novel technology is a candidate to a novel generation of highly-integrated, comfortable and reliable technologies that measure physiological signals in real-life scenarios.

[1]  Refet Firat Yazicioglu,et al.  A 160μW 8-channel active electrode system for EEG monitoring , 2011, 2011 IEEE International Solid-State Circuits Conference.

[2]  Wen H. Ko,et al.  Active electrodes for EEG and evoked potential , 1998, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286).

[3]  Andy Adler,et al.  Electrical impedance tomography system based on active electrodes , 2012, Physiological measurement.

[4]  C A Grimbergen,et al.  High-quality recording of bioelectric events , 1990, Medical and Biological Engineering and Computing.

[5]  Keith D. Paulsen,et al.  A multichannel continuously selectable multifrequency electrical impedance spectroscopy measurement system , 2000, IEEE Transactions on Biomedical Engineering.

[6]  P Zipp,et al.  A model of bioelectrode motion artefact and reduction of artefact by amplifier input stage design. , 1979, Journal of biomedical engineering.

[7]  Graham A. Mills,et al.  In Situ Sensors for Monitoring the Marine Environment , 2014 .

[8]  C A Grimbergen,et al.  High-quality recording of bioelectric events , 1991, Medical and Biological Engineering and Computing.

[9]  B. Rigaud,et al.  Experimental acquisition system for impedance tomography with active electrode approach , 2006, Medical and Biological Engineering and Computing.

[10]  G.J. Saulnier,et al.  ACT3: a high-speed, high-precision electrical impedance tomograph , 1991, IEEE Transactions on Biomedical Engineering.

[11]  Madhav Kumar,et al.  A high CMRR analog front-end IC for wearable physiological monitoring , 2012, 2012 Annual IEEE India Conference (INDICON).

[12]  Michael Faulkner,et al.  A Survey on Intrabody Communications for Body Area Network Applications , 2013, IEEE Transactions on Biomedical Engineering.

[13]  D. Djajaputra Electrical Impedance Tomography: Methods, History and Applications , 2005 .

[14]  Olivier Chételat,et al.  A Highly Integrated Wearable Multi-parameter Monitoring System for Athletes , 2011 .

[15]  Heinz Jäckel,et al.  Continuous Monitoring of Electrode--Skin Impedance Mismatch During Bioelectric Recordings , 2008, IEEE Transactions on Biomedical Engineering.

[16]  Suhas S. Joshi,et al.  Passive blood plasma separation at the microscale: a review of design principles and microdevices , 2015 .

[17]  Geng Yang,et al.  A novel wearable ECG monitoring system based on active-cable and intelligent electrodes , 2008, HealthCom 2008 - 10th International Conference on e-health Networking, Applications and Services.

[18]  Jens Krauss,et al.  Getting rid of the wires and connectors in physiological monitoring , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  Lawrence M Knuckey,et al.  EPSM 2005 Workshop - IEC 60601-1: Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance - 3rd Edition 2005 , 2006 .

[20]  Refet Firat Yazicioglu,et al.  A $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring , 2011, IEEE Transactions on Biomedical Circuits and Systems.