Oscillating steady states

The signal formation and properties of steady‐state free precession (SSFP) in combination with alternating RF pulse phases or alternating spin precession is analyzed. Simulations and experiments demonstrate that the amplitudes of SSFP echo paths are significantly influenced by application of alternating phases either via the exciting RF pulse or via some external mechanism producing alternating spin precession. The influence of alternating phases on echo amplitudes is different for different echo paths. The primary SSFP echo paths F0− and F0+ exhibit a signal reduction whereas higher‐order echoes F−1− and F1+ show a signal increase upon application of oscillating phases. This behavior can be described using a simple perturbation theory applied to the frequency response profile of balanced SSFP combined with a final signal integration over one balanced SSFP band. The high sensitivity of SSFP echo amplitudes to alternating RF pulse phases or precession is exemplarily used to detect and visualize propagating transverse acoustic shear waves. Detection of flow or alternating currents are further possibilities to apply this unique feature of SSFP. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.

[1]  S Maderwald,et al.  Balanced alternating steady‐state elastography , 2006, Magnetic resonance in medicine.

[2]  R. Freeman,et al.  Phase and intensity anomalies in fourier transform NMR , 1971 .

[3]  K. Scheffler,et al.  Analysis and compensation of eddy currents in balanced SSFP , 2005, Magnetic resonance in medicine.

[4]  W. Hinshaw,et al.  Image formation by nuclear magnetic resonance: The sensitive‐point method , 1976 .

[5]  Comparative studies of phase-cycling schemes for multiple pi-pulse sequences. , 1997, Journal of magnetic resonance.

[6]  Mark E. Ladd,et al.  Design of an MR‐compatible piezoelectric actuator for MR elastography , 2002 .

[7]  M. L. Wood,et al.  Spoiling of transverse magnetization in steady‐state sequences , 1991, Magnetic resonance in medicine.

[8]  D G Nishimura,et al.  Linear combination steady‐state free precession MRI , 2000, Magnetic resonance in medicine.

[9]  D G Nishimura,et al.  Fluctuating equilibrium MRI , 1999, Magnetic resonance in medicine.

[10]  J. Hennig Multiecho imaging sequences with low refocusing flip angles , 1988 .

[11]  Analysis of the higher‐order echoes in SSFP , 1991, Magnetic resonance in medicine.

[12]  Dwight G Nishimura,et al.  Oscillating dual‐equilibrium steady‐state angiography , 2002, Magnetic resonance in medicine.

[13]  Mark E Ladd,et al.  In vivo elasticity measurements of extremity skeletal muscle with MR elastography , 2004, NMR in biomedicine.

[14]  D. Hoult The solution of the bloch equations in the presence of a varying B1 field—An approach to selective pulse analysis , 1979 .

[15]  E. T. Jaynes,et al.  MATRIX TREATMENT OF NUCLEAR INDUCTION , 1955 .