Mechanical characteristics of knee extension exercises performed on an isokinetic dynamometer.
暂无分享,去创建一个
J G Hay | J W Chow | W G Darling | J. Hay | J. Chow | W. Darling
[1] H J Hislop,et al. The isokinetic concept of exercise. , 1967, Physical therapy.
[2] A. Thorstensson,et al. Force-velocity relations and fiber composition in human knee extensor muscles. , 1976, Journal of applied physiology.
[3] V. Edgerton,et al. Torque-velocity relationships and muscle fiber composition in elite female athletes. , 1979, Journal of applied physiology: respiratory, environmental and exercise physiology.
[4] V R Edgerton,et al. Training-induced alterations of the in vivo force-velocity relationship of human muscle. , 1981, Journal of applied physiology: respiratory, environmental and exercise physiology.
[5] P B Pynsent,et al. A simple program for a phaseless recursive digital filter. , 1982, Journal of biomedical engineering.
[6] L Gransberg,et al. Determination of dynamic muscle strength in man with acceleration controlled isokinetic movements. , 1983, Acta physiologica Scandinavica.
[7] J. Richards,et al. Analysis of the reliability and validity of the kinetic communicator exercise device. , 1986, Medicine and science in sports and exercise.
[8] D. Murray. Optimal filtering of constant velocity torque data. , 1986, Medicine and science in sports and exercise.
[9] D A Murray,et al. Constant velocity dynamometer: an appraisal using mechanical loading. , 1986, Medicine and science in sports and exercise.
[10] M. Fillyaw,et al. Importance of correcting isokinetic peak torque for the effect of gravity when calculating knee flexor to extensor muscle ratios. , 1986, Physical therapy.
[11] R J Robertson,et al. Bilateral lsokinetic Peak Torque, Torque Acceleration Energy, Power, and Work Relationships in Athletes and Nonathletes. , 1987, The Journal of orthopaedic and sports physical therapy.
[12] J M Rothstein,et al. Clinical uses of isokinetic measurements. Critical issues. , 1987, Physical therapy.
[13] W Herzog,et al. The relation between the resultant moments at a joint and the moments measured by an isokinetic dynamometer. , 1988, Journal of biomechanics.
[14] V. Baltzopoulos,et al. Isokinetic Dynamometry , 1989, Sports medicine.
[15] S. Kegerreis,et al. Comparison of Values Generated During Testing of the Knee Using the Cybex II Plus® and Biodex Model B-2000® Isokinetic Dynamometers1 , 1989 .
[16] J. Seger,et al. Eccentric and Concentric Torque-Velocity Characteristics, Torque Output Comparisons, and Gravity Effect Torque Corrections for the Quadriceps and Hamstring Muscles in Females , 1989, International journal of sports medicine.
[17] Michael T. Gross,et al. Intramachine and Intermachine Reliability of the Biodex and Cybex® II for Knee Flexion and Extension Peak Torque and Angular Work , 1991 .
[18] L. A. Patterson,et al. Validity and Reliability of the LIDO Active Isokinetic System. , 1992, The Journal of orthopaedic and sports physical therapy.
[19] C A Smith,et al. The warm-up procedure: to stretch or not to stretch. A brief review. , 1994, The Journal of orthopaedic and sports physical therapy.