Sub-micron resolution CT for failure analysis and process development

Many modern industrial processes and research applications place increasingly higher demands on x-ray computed tomography (CT) imaging resolution and sensitivity for low-contrast specimens with a low atomic number. The three approaches to increasing imaging resolution are (1) reduction in the x-ray spot size, (2) use of higher resolution detectors or (3) employment of x-ray optical elements. Systems that pursue one or more of these approaches are available and under continued development. The Xradia MicroXCT™ projection-type microscope described in this paper has been optimized for high-resolution x-ray CT by employing a high-resolution detector paired with a microfocus x-ray source. Large working distances in this CT system enable full tomographic data collection at micrometre resolution of large samples, such as flip-chip packages. X-ray CT instruments using x-ray optical elements for condenser optics and imaging objective lenses are a new development capable of reaching sub-50 nm resolution. These instruments find various applications, including die-level imaging in the semiconductor industry as well as the process development for fuel cells, which we describe here as one application. Sub-micron resolution CT instruments without x-ray optical elements have a large application base already; however, new instruments optimized for soft materials and low-contrast specimens, such as the Xradia nanoXCT™, offer completely new capabilities and open new applications. New developments in the area of phase contrast imaging enable unprecedented image contrast for specimens with very low absorption, which for research applications enables for the first time the imaging of many specimens in their natural state (e.g., arteries to examine calcification). Zernike phase contrast for sub-50 nm x-ray CT even enables the imaging of single cell or thin tissue slices for biological or medical applications.

[1]  Michael Feser,et al.  Nanofabrication of high aspect ratio 24nm x-ray zone plates for x-ray imaging applications , 2007 .

[2]  Kyle N. Grew,et al.  Nondestructive Reconstruction and Analysis of Solid Oxide Fuel Cell Anodes using X-ray Computed Tomography at sub-50 nm Resolution , 2008 .

[3]  E. Anderson,et al.  Soft X-ray microscopy at a spatial resolution better than 15 nm , 2005, Nature.

[4]  Yoshiharu Namba,et al.  Compact soft x-ray transmission microscopy with sub-50 nm spatial resolution , 2006, Physics in medicine and biology.

[5]  David Attwood,et al.  Microscopy: Nanotomography comes of age , 2006, Nature.

[6]  W. Yun,et al.  Ellipsoidal and parabolic glass capillaries as condensers for x-ray microscopes. , 2008, Applied optics.

[7]  Hongtao Cui,et al.  X-ray computed tomography in Zernike phase contrast mode at 8 keV with 50-nm resolution using Cu rotating anode X-ray source , 2007 .

[8]  Andreas Koch,et al.  X-ray imaging with submicrometer resolution employing transparent luminescent screens , 1998 .

[9]  M. Young Zone Plates and Their Aberrations , 1972 .

[10]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[11]  Jon M. Hiller,et al.  Three-dimensional reconstruction of a solid-oxide fuel-cell anode , 2006, Nature materials.

[12]  Wilson K. S. Chiu,et al.  Nondestructive Reconstruction and Analysis of SOFC Anodes Using X-ray Computed Tomography at Sub-50 nm Resolution , 2008 .

[13]  B. Niemann,et al.  Amplitude- and Phase-Contrast X-Ray Microscopy , 1988, Short Wavelength Coherent Radiation: Generation and Applications.

[14]  Q. Shen,et al.  Hard x-ray microscopy with Fresnel zone plates reaches 40 nm Rayleigh resolution. , 2008 .