Closure of Atrial Septal Defects: Is there Still a Place for Surgery ?

Abstract Background: The purpose of this study is to assess the current management of atrial septal defect closure in an era of increasing feasibility of transcatheter device occlusion. Methods: Atrial septal defect (ASD) closure was performed surgically through complete sternotomy in 165 patients (group 1) and through partial inferior sternotomy in 53 patients (group 2). Transcatheter device occlusion was achieved in 82 patients with only ASD type II and patent foramen ovale (group 3). Results: Overall complications were minor and more frequent in group 1: 26.7% versus 13.2% in group 2 and 14.6% in group 3 (p = 0.04). Compared to complete sternotomy, a partial sternotomy led to less chest tube loss (7.1 ± 2.9 versus 11.6 ± 14.5 ml/kg) (p < 0.05) and less postoperative pericardial effusion (11.3% versus 13.5%)(p = 0.55). ASD closure was effective in 99.4% in group 1, 100% in group 2 but only in 86.6% in group 3 (p < 0.05). Two major complications of device implantation required early surgery: 1 femoral arteriovenous fistula and 1 device embolization. Hospital stay was significantly shorter in group 3, as well as in group 2 compared to group 1 (8.3 ± 4.2 versus 5.9 ± 1.1 versus 2.1 ± 7.3 days) (p < 0.05). Midterm results were excellent, with only 1 non-cardiac death and 1 re-operation for residual shunt in group 1, and 1 device removal for thrombosis in group 3. Conclusion: Transcatheter device occlusion has become an established treatment for ASD closure, achieving optimal results in older children and adults with anatomically suited ASD type II and PFO. However, a partial inferior sternotomy offers a valuable and complementary operative approach for all ASD variants, maintaining the predictable success of surgery, with the obvious advantages of minimal access in terms of morbidity, cosmetics and hospital stay.

[1]  H. Sievert,et al.  Incidence and clinical course of thrombus formation on atrial septal defect and patient foramen ovale closure devices in 1,000 consecutive patients. , 2004, Journal of the American College of Cardiology.

[2]  K. Larntz,et al.  Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: results of a multicenter nonrandomized trial. , 2002, Journal of the American College of Cardiology.

[3]  E. Bossone,et al.  Early and late complications associated with transcatheter occlusion of secundum atrial septal defect. , 2002, Journal of the American College of Cardiology.

[4]  L. Pasquini,et al.  Minimally invasive or interventional repair of atrial septal defects in children: experience in 171 cases and comparison with conventional strategies. , 2001, Journal of the American College of Cardiology.

[5]  C. Chang,et al.  Ministernotomy versus full sternotomy in congenital heart defects: a prospective randomized study. , 2001, The Annals of thoracic surgery.

[6]  P. D. del Nido,et al.  Postoperative recovery in children after minimum versus full-length sternotomy. , 2000, The Annals of thoracic surgery.

[7]  D. McElhinney,et al.  A 5-year experience with surgical repair of atrial septal defect employing limited exposure , 1999, Cardiology in the Young.

[8]  P. Lange,et al.  Comparison of results and complications of surgical and Amplatzer device closure of atrial septal defects. , 1999, The Journal of thoracic and cardiovascular surgery.

[9]  R. Freedom,et al.  Minimally invasive repair of atrial septal defects. , 1998, The Annals of thoracic surgery.

[10]  A. Jatene,et al.  Transxiphoid approach without median sternotomy for the repair of atrial septal defects. , 1998, The Annals of thoracic surgery.

[11]  T. Folliguet,et al.  Right anterolateral thoracotomy for repair of atrial septal defect. , 1996, The Annals of thoracic surgery.

[12]  M. Olschewski,et al.  A comparison of surgical and medical therapy for atrial septal defect in adults. , 1995, The New England journal of medicine.

[13]  R. Wilson,et al.  Experimental Atrial Septal Defect Closure With a New, Transcatheter, Self‐Centering Device , 1993, Circulation.

[14]  E. Sideris,et al.  Transvenous atrial septal defect occlusion by the buttoned device. , 1990, The American journal of cardiology.

[15]  J. F. Keane,et al.  Double-umbrella closure of atrial defects. Initial clinical applications. , 1990, Circulation.

[16]  C. Leier,et al.  Prolonged Atrial Conduction: A Major Predisposing Factor for the Development of Atrial Flutter , 1978, Circulation.