Characterizing noise and perceived work environment in a neurological intensive care unit.

The hospital sound environment is complex. Alarms, medical equipment, activities, and ventilation generate noise that may present occupational problems as well as hinder recovery among patients. In this study, sound measurements and occupant evaluations were conducted in a neurological intensive care unit. Staff completed questionnaires regarding psychological and physiological reactions to the sound environment. A-weighted equivalent, minimum, and maximum (L(Aeq),L(AFMin),L(AFMax)) and C-weighted peak (L(CPeak)) sound pressure levels were measured over five days at patient and staff locations. Acoustical descriptors that may be explored further were investigated, including level distributions, restorative periods, and spectral content. Measurements near the patients showed average L(Aeq) values of 53-58 dB. The mean length of restorative periods (L(Aeq) below 50 dB for more than 5 min) was 9 and 13 min for day and night, respectively. Ninety percent of the time, the L(AFMax) levels exceeded 50 dB and L(CPeak) exceeded 70 dB. Dosimeters worn by the staff revealed higher noise levels. Personnel perceived the noise as contributing to stress symptoms. Compared to the majority of previous studies, this study provides a more thorough description of intensive care noise and aids in understanding how the sound environment may be disruptive to occupants.

[1]  Inger Hagerman,et al.  Influence of intensive coronary care acoustics on the quality of care and physiological state of patients. , 2004, International journal of cardiology.

[2]  V S Murthy,et al.  Detrimental effects of noise on anaesthetists , 1995, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[3]  J. Edworthy,et al.  Are there too many alarms in the intensive care unit? An overview of the problems. , 1995, Journal of advanced nursing.

[4]  J. West,et al.  Noise levels in Johns Hopkins Hospital. , 2005, The Journal of the Acoustical Society of America.

[5]  C. Tsiou,et al.  Noise sources and levels in the evgenidion hospital intensive care unit , 1998, Intensive Care Medicine.

[6]  B. Walder,et al.  Effects of guidelines implementation in a surgical intensive care unit to control nighttime light and noise levels , 2000, Critical care medicine.

[7]  E. Oehrstroem EFFECTS OF LOW LEVELS OF ROAD TRAFFIC NOISE DURING THE NIGHT: A LABORATORY STUDY ON NUMBER OF EVENTS, MAXIMUM NOISE LEVELS AND NOISE SENSITIVITY , 1995 .

[8]  Jonathan M Kracht,et al.  Noise in the operating rooms of Johns Hopkins Hospital. , 2007, The Journal of the Acoustical Society of America.

[9]  G. Bernard,et al.  The impact of delirium in the intensive care unit on hospital length of stay , 2001, Intensive Care Medicine.

[10]  Birgitta Berglund,et al.  Scaling loudness, noisiness, and annoyance of community noises , 1976 .

[11]  S A Falk,et al.  Hospital noise--levels and potential health hazards. , 1973, The New England journal of medicine.

[12]  Wim van Drongelen,et al.  Noise in contemporary neonatal intensive care. , 2007, The Journal of the Acoustical Society of America.

[13]  Mark S. Wallace,et al.  Hearing Acuity of Anesthesiologists and Alarm Detection , 1992 .

[14]  Laurent Galbrun,et al.  Noise levels and noise sources in acute care hospital wards , 2007 .

[15]  Lincoln Gray,et al.  Changing Levels of Quiet in an Intensive Care Nursery , 2002, Journal of Perinatology.

[16]  E. Pedersen,et al.  Perception and annoyance due to wind turbine noise--a dose-response relationship. , 2004, The Journal of the Acoustical Society of America.

[17]  D. Bredle,et al.  Name that tone. The proliferation of alarms in the intensive care unit. , 1994, Chest.

[18]  D. Lundberg,et al.  Patients' experience of being critically ill or severely injured and cared for in an intensive care unit in relation to the ICU syndrome. Part I. , 1998, Intensive & critical care nursing.

[19]  W. Passchier,et al.  Noise exposure and public health. , 2000, Environmental health perspectives.

[20]  R. Ulrich,et al.  Acoustics and psychosocial environment in intensive coronary care , 2005, Occupational and Environmental Medicine.

[21]  A. Benzer,et al.  Noise in the ICU , 2005, Intensive Care Medicine.

[22]  B. Garvin,et al.  The effect of environmental sound and communication on CCU patients' heart rate and blood pressure. , 1993, Research in nursing & health.

[23]  James E West,et al.  Noise in the adult emergency department of Johns Hopkins Hospital. , 2006, The Journal of the Acoustical Society of America.

[24]  B B Minckley,et al.  A STUDY OF NOISE AND ITS RELATIONSHIP TO PATIENT DISCOMFORT IN THE RECOVERY ROOM , 1968, Nursing research.

[25]  C. F. Baker,et al.  The CCU patient: Anxiety and annoyance to noise , 1989, Critical care nursing quarterly.

[26]  Lois M. Stanford,et al.  Audible alarm signals for anaesthesia monitoring equipment , 1985, International journal of clinical monitoring and computing.

[27]  R. Millman,et al.  Adverse environmental conditions in the respiratory and medical ICU settings. , 1994, Chest.

[28]  Patricia A. Martin,et al.  NICU Sound Environment and the Potential Problems for Caregivers , 2000, Journal of Perinatology.

[29]  H. G. Leventhall,et al.  EFFECTS ON PERFORMANCE AND WORK QUALITY DUE TO LOW FREQUENCY VENTILATION NOISE , 1997 .

[30]  Jeffrey Dunn,et al.  Quieting Weinberg 5C: a case study in hospital noise control. , 2007, The Journal of the Acoustical Society of America.

[31]  J. H. Kerr,et al.  An “Alarming” situation in the intensive therapy unit , 2005, Intensive Care Medicine.

[32]  Sairam Parthasarathy,et al.  Sleep in the intensive care unit , 2004, Intensive Care Medicine.

[33]  M Topf,et al.  Noise-induced occupational stress and health in critical care nurses. , 1988, Hospital topics.

[34]  W. R. Waugh,et al.  Sound Level Exposure of High-Risk Infants in Different Environmental Conditions , 2006, Neonatal Network.

[35]  N. Rosencher,et al.  The Shivering Threshold during Spinal Anesthesia Is Reduced in the Elderly , 1994 .

[36]  B. Morris,et al.  Do former preterm infants remember and respond to neonatal intensive care unit noise? , 2006, Early human development.

[37]  Aitken Rj Quantitative noise analysis in a modern hospital. , 1982 .

[38]  B A Hilton Noise in acute patient care areas , 1985, Research in nursing & health.

[39]  Ellen C Haas,et al.  Noise, stress, and annoyance in a pediatric intensive care unit , 2003, Critical care medicine.

[40]  J. Byers,et al.  Noise and the premature infant: physiological effects and practice implications. , 2003, Journal of obstetric, gynecologic, and neonatal nursing : JOGNN.

[41]  D Fife,et al.  Noise and hospital stay. , 1976, American journal of public health.

[42]  Sidney Fels,et al.  An Evaluation of a Vibro-Tactile Display Prototype for Physiological Monitoring , 2005, Anesthesia and analgesia.

[43]  M. Björkman,et al.  A descriptive cross-sectional study of annoyance from low frequency noise installations in an urban environment. , 2003, Noise & health.

[44]  U. Edéll-Gustafsson,et al.  Noise and sleep disturbance factors before and after implementation of a behavioural modification programme. , 2005, Intensive & critical care nursing.

[45]  Leslie Parker,et al.  Elevated Sound Levels within a Busy NICU , 2005, Neonatal Network.

[46]  R. Millman,et al.  Identification and modification of environmental noise in an ICU setting. , 1998, Chest.

[47]  H. Lane,et al.  The Lombard Sign and the Role of Hearing in Speech , 1971 .

[48]  Jane H. Barnsteiner,et al.  Clinical Alarms: Improving Efficiency and Effectiveness , 2005, Critical care nursing quarterly.

[49]  Erica E. Ryherd,et al.  Effects of exposure duration and type of task on subjective performance and perception in noise , 2007 .