Transient electromagnetic responses of 3D polarizable body

The transient voltage response of a central loop electromagnetic system above a buried polarizable parallelepiped target (such as pyrites, sulfides, clays, etc.) is studied. The voltage response, which includes a positive part and a negative part (related to the polarization properties), is studied by varying the body characteristics, including the Cole-Cole parameters, body dimensions, depth, and thickness. By varying the loop radius and by using profiling, the lateral body dimensions can be identified, particularly using the negative response for polarizable bodies. There is a clear difference in the dependencies of the positive and negative voltage responses on the body characteristics, which means that the negative voltage is not just redundant data, but we may use it, together with the positive response, to have better understanding for the body dimensions and polarization parameters effects.

[1]  Roger Guérin,et al.  Improvement in TDEM sounding interpretation in presence of induced polarization. A case study in resistive rocks of the Fogo volcano, Cape Verde Islands , 2000 .

[2]  S. A. Hussain,et al.  Optimum negative response of a coincident‐loop electromagnetic system above a polarizable half‐space , 1997 .

[3]  Richard S. Smith,et al.  A special circumstance of airborne induced-polarization measurements , 1996 .

[4]  S. A. Hussain,et al.  Effect of clayey media parameters on the negative response of a coincident loop1 , 1995 .

[5]  Terry J. Lee,et al.  THE TRANSIENT ELECTROMAGNETIC RESPONSE OF A POLARIZABLE SPHERE IN A CONDUCTING HALF SPACE1 , 1992 .

[6]  G. W. Hohmann,et al.  Transient electromagnetic responses of surficial, polarizable patches , 1990 .

[7]  Richard S. Smith,et al.  Field examples of negative coincident‐loop transient electromagnetic responses modeled with polarizable half‐planes , 1989 .

[8]  Gregory A. Newman,et al.  Induced-polarization effects in time-domain electromagnetic measurements , 1989 .

[9]  Richard S. Smith,et al.  An explanation of abnormal TEM responses: coincident-loop negatives, and the loop effect. , 1988 .

[10]  Terry J. Lee,et al.  Time-Domain Electromagnetic Responses of a Polarizable Target , 1988 .

[11]  P. Elliott Negative SIROTEM anomalies ? case studies , 1987 .

[12]  M. Flis IP effects in 3-D TEM data ? theory and case histories , 1987 .

[13]  Gregory A. Newman,et al.  Transient electromagnetic response of a three-dimensional body in a layered earth , 1986 .

[14]  B. Spies,et al.  Limitations of large‐loop transient electromagnetic surveys in conductive terrains , 1984 .

[15]  T. Lee,et al.  Transient electromagnetic response of a polarizable ground , 1981 .

[16]  Stanley H. Ward,et al.  Mineral discrimination and removal of inductive coupling with multifrequency IP , 1978 .

[17]  D. Fitterman Detectability levels for central induction transient soundings , 1989 .