Optimal Planning of Distributed Generators and Shunt Capacitors in Isolated Microgrids With Nonlinear Loads

This article presents a comprehensive design procedure for isolated microgrids with a high penetration of nonlinear loads. The proposed microgrid planning approach simultaneously determines the sizes, locations and types of distributed generators (DGs) and shunt capacitor banks (CBs). The presence of nonlinear loads along with the capacitors of CBs or DGs’ output filters may cause severe voltage distortions. To consider this issue, a harmonic power flow tool tailored for planning applications is developed that takes into account the specific features of isolated microgrids. Given the necessity of supply continuity for isolated microgrids after a contingency, the proposed planning approach takes into consideration the reliability to increase the probability of building successful islands. Unlike previous methods, the proposed approach does not rely merely on supply adequacy, and takes into account the fact that the voltage provision requirement can only be fulfilled through dispatchable DGs. The intermittent natures of loads and renewable DGs are modelled probabilistically. The effectiveness of the proposed planning approach has been validated using the PG&E 69-bus system, and the followings are observed: 1) the significance of applying suitable fundamental-power-flow and harmonic-power-flow algorithms for isolated microgrids, and 2) the possibility of avoiding a severe voltage distortion by utilizing an appropriate planning method and only small increase in the cost.

[1]  Ehab F. El-Saadany,et al.  Optimum Shunt Capacitor Placement in Multimicrogrid Systems With Consideration of Islanded Mode of Operation , 2015, IEEE Transactions on Sustainable Energy.

[2]  Mehrdad Kazerani,et al.  A Generalized Platform for Optimal Planning of Isolated Microgrids, Considering Operation Constraints , 2018, IECON 2018 - 44th Annual Conference of the IEEE Industrial Electronics Society.

[3]  Kankar Bhattacharya,et al.  Stochastic Optimal Planning of Battery Energy Storage Systems for Isolated Microgrids , 2018, IEEE Transactions on Sustainable Energy.

[4]  M. E. Baran,et al.  Optimal capacitor placement on radial distribution systems , 1989 .

[5]  F. Blaabjerg,et al.  Control of Power Converters in AC Microgrids , 2012, IEEE Transactions on Power Electronics.

[6]  E. S. Karapidakis,et al.  Hybrid Simulated Annealing–Tabu Search Method for Optimal Sizing of Autonomous Power Systems With Renewables , 2012, IEEE Transactions on Sustainable Energy.

[7]  Magdy M. A. Salama,et al.  An Incentive-Based Multistage Expansion Planning Model for Smart Distribution Systems , 2018, IEEE Transactions on Power Systems.

[8]  Yun Wei Li,et al.  Hybrid Voltage and Current Control Approach for DG-Grid Interfacing Converters With LCL filters , 2013, IEEE Transactions on Industrial Electronics.

[9]  Bo Zhao,et al.  Optimal sizing, operating strategy and operational experience of a stand-alone microgrid on Dongfushan Island , 2014 .

[10]  Oriol Gomis-Bellmunt,et al.  Trends in Microgrid Control , 2014, IEEE Transactions on Smart Grid.

[11]  Y. Liu,et al.  Test systems for harmonics modeling and simulation , 1999 .

[12]  Scott D. Sudhoff,et al.  Analysis of Electric Machinery and Drive Systems , 1995 .

[13]  Jin Jiang,et al.  Accurate Reactive Power Sharing in an Islanded Microgrid Using Adaptive Virtual Impedances , 2015, IEEE Transactions on Power Electronics.

[14]  Frede Blaabjerg,et al.  Wide Frequency Band Active Damping Strategy for DFIG System High Frequency Resonance , 2016, IEEE Transactions on Energy Conversion.

[15]  Task Force,et al.  Characteristics and Modeling of Harmonic Sources-Power Electronic Devices , 2001, IEEE Power Engineering Review.

[16]  Zhixin Miao,et al.  Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network , 2012, IEEE Transactions on Energy Conversion.

[17]  Mostafa F. Shaaban,et al.  An Efficient Planning Algorithm for Hybrid Remote Microgrids , 2019, IEEE Transactions on Sustainable Energy.

[18]  Frede Blaabjerg,et al.  High-Frequency Resonance Damping of DFIG-Based Wind Power System Under Weak Network , 2017, IEEE Transactions on Power Electronics.

[19]  Yasser Abdel-Rady I. Mohamed,et al.  Optimized Multiple Microgrid-Based Clustering of Active Distribution Systems Considering Communication and Control Requirements , 2015, IEEE Transactions on Industrial Electronics.

[20]  Benvindo R. Pereira,et al.  Optimal Distributed Generation and Reactive Power Allocation in Electrical Distribution Systems , 2016, IEEE Transactions on Sustainable Energy.

[21]  Claudio A. Canizares,et al.  Long-Term Renewable Energy Planning Model for Remote Communities , 2016, IEEE Transactions on Sustainable Energy.

[22]  Weidong Xiao,et al.  Determining Optimal Location and Size of Distributed Generation Resources Considering Harmonic and Protection Coordination Limits , 2013, IEEE Transactions on Power Systems.

[23]  Ehab F. El-Saadany,et al.  Optimal Configuration of Isolated Hybrid AC/DC Microgrids , 2019, IEEE Transactions on Smart Grid.

[24]  Matti Lehtonen,et al.  Optimal Energy Trading for Renewable Energy Integrated Building Microgrids Containing Electric Vehicles and Energy Storage Batteries , 2019, IEEE Access.

[25]  Gilbert M. Masters,et al.  Renewable and Efficient Electric Power Systems , 2004 .

[26]  Poh Chiang Loh,et al.  Design, analysis, and real-time testing of a controller for multibus microgrid system , 2004, IEEE Transactions on Power Electronics.

[27]  Amesh,et al.  Optimal Capacitor Placement and Sizing in Unbalanced Distribution Systems with Harmonics Consideration using Particle Swarm Optimization , 2013 .

[28]  Mahmud Fotuhi-Firuzabad,et al.  Stochastic Capacity Expansion Planning of Remote Microgrids With Wind Farms and Energy Storage , 2015, IEEE Transactions on Sustainable Energy.

[29]  Probability Subcommittee,et al.  IEEE Reliability Test System , 1979, IEEE Transactions on Power Apparatus and Systems.

[30]  Frede Blaabjerg,et al.  Impedance-Based High-Frequency Resonance Analysis of DFIG System in Weak Grids , 2017, IEEE Transactions on Power Electronics.

[31]  Jun Xiao,et al.  Sizing of Energy Storage and Diesel Generators in an Isolated Microgrid Using Discrete Fourier Transform (DFT) , 2014, IEEE Transactions on Sustainable Energy.

[32]  Ehab F. El-Saadany,et al.  A Novel and Generalized Three-Phase Power Flow Algorithm for Islanded Microgrids Using a Newton Trust Region Method , 2013, IEEE Transactions on Power Systems.

[33]  Fei Wang,et al.  Modeling and Analysis of Grid Harmonic Distortion Impact of Aggregated DG Inverters , 2011, IEEE Transactions on Power Electronics.

[34]  Russell Bent,et al.  Security-Constrained Design of Isolated Multi-Energy Microgrids , 2018, IEEE Transactions on Power Systems.

[35]  Peter Vas,et al.  Sensorless vector and direct torque control , 1998 .

[36]  Ali Ehsan,et al.  Coordinated Investment Planning of Distributed Multi-Type Stochastic Generation and Battery Storage in Active Distribution Networks , 2019, IEEE Transactions on Sustainable Energy.

[37]  Ian A. Hiskens,et al.  Coupling Between Component Sizing and Regulation Capability in Microgrids , 2013, IEEE Transactions on Smart Grid.

[38]  Ehab F. El-Saadany,et al.  Probabilistic approach for optimal planning of distributed generators with controlling harmonic distortions , 2013 .

[39]  Han Li,et al.  Grid-Price Dependent Optimal Energy Storage Management Strategy for Grid-Connected Industrial Microgrids , 2017, 2017 Ninth Annual IEEE Green Technologies Conference (GreenTech).