A dual-source miniature mass spectrometer with improved sensitivity

Abstract Previously, we have reported the development of a miniature mass spectrometer with a continuous atmospheric pressure interface, whose sensitivity was sacrificed due to the limited gas flow rate. In this study, a circular lens was designed and integrated on the ion transfer pathway between the two pumping stages, and a ten-fold sensitivity improvement could be achieved when coupling with external ionization sources. Besides the capability of working with ionization sources in the atmosphere, there is also an in-vacuum plasma ionization source, so that both volatile and non-volatile samples could be analyzed. A 10 ppbv detection sensitivity was achieved for dimethyl methyl phosphonate (DMMP) in air using the plasma ionization source. Furthermore, the miniature mass spectrometer was also demonstrated for the direct analyses of progesterone in drinking water and atrazine in soil samples using paper spray and syringe spray, respectively.

[1]  A. Hawkins,et al.  Miniaturization of a planar-electrode linear ion trap mass spectrometer. , 2014, Rapid communications in mass spectrometry : RCM.

[2]  Zheng Ouyang,et al.  Breaking the pumping speed barrier in mass spectrometry: discontinuous atmospheric pressure interface. , 2008, Analytical chemistry.

[3]  R. Cooks,et al.  Glow discharge electron impact ionization source for miniature mass spectrometers. , 2007, Journal of mass spectrometry : JMS.

[4]  Zheng Ouyang,et al.  Rapid discrimination of bacteria using a miniature mass spectrometer. , 2016, The Analyst.

[5]  N. Gimelshein,et al.  Numerical Modeling of Ion Transport in an ESI-MS System , 2013, Journal of The American Society for Mass Spectrometry.

[6]  R. Cooks,et al.  Direct identification of prohibited substances in cosmetics and foodstuffs using ambient ionization on a miniature mass spectrometry system. , 2016, Analytica chimica acta.

[7]  Wanderson Romão,et al.  Ambient mass spectrometry: bringing MS into the “real world” , 2010, Analytical and bioanalytical chemistry.

[8]  J. Nilles,et al.  Quantitation of chemical warfare agents using the direct analysis in real time (DART) technique. , 2009, Analytical Chemistry.

[9]  J. Henion,et al.  High-speed liquid chromatography/tandem mass spectrometry for the determination of drugs in biological samples. , 1986, Analytical chemistry.

[10]  W. Xu,et al.  An aerodynamic assisted miniature mass spectrometer for enhanced volatile sample analysis. , 2016, The Analyst.

[11]  Anthony B. Costa,et al.  New ionization methods and miniature mass spectrometers for biomedicine: DESI imaging for cancer diagnostics and paper spray ionization for therapeutic drug monitoring. , 2011, Faraday discussions.

[12]  J. Sunner,et al.  Ion transport by viscous gas flow through capillaries , 1994, Journal of the American Society for Mass Spectrometry.

[13]  R. Cooks,et al.  A miniature cylindrical quadrupole ion trap:  simulation and experiment. , 1998, Analytical Chemistry.

[14]  Zheng Ouyang,et al.  Miniature mass spectrometers. , 2009, Annual review of analytical chemistry.

[15]  Guido F Verbeck,et al.  Vehicle-Mounted Portable Mass Spectrometry System for the Covert Detection via Spatial Analysis of Clandestine Methamphetamine Laboratories. , 2015, Analytical chemistry.

[16]  C. Janfelt,et al.  Characterization of a mini membrane inlet mass spectrometer for on-site detection of contaminants in both aqueous and liquid organic samples. , 2006, Rapid communications in mass spectrometry : RCM.

[17]  J. S. Wiley,et al.  Handheld low-temperature plasma probe for portable "point-and-shoot" ambient ionization mass spectrometry. , 2013, Analytical chemistry.

[18]  R. Kostiainen,et al.  Liquid chromatography/atmospheric pressure ionization-mass spectrometry in drug metabolism studies. , 2003, Journal of mass spectrometry : JMS.

[19]  Zheng Ouyang,et al.  Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer. , 2004, Analytical chemistry.

[20]  P. Savage,et al.  Field-portable gas chromatography with transmission quadrupole and cylindrical ion trap mass spectrometric detection: Chromatographic retention index data and ion/molecule interactions for chemical warfare agent identification , 2010 .

[21]  R. Graham Cooks,et al.  Ambient desorption ionization mass spectrometry , 2008 .

[22]  W. Whitten,et al.  Microfabricated quadrupole ion trap for mass spectrometer applications. , 2006, Physical review letters.

[23]  S. Rice,et al.  Mass Spectrometry of Organic Ions , 1964 .

[24]  A. Fernie,et al.  Gas chromatography mass spectrometry–based metabolite profiling in plants , 2006, Nature Protocols.

[25]  M. Bogusz,et al.  Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[26]  W. Xu,et al.  Study of Discontinuous Atmospheric Pressure Interfaces for Mass Spectrometry Instrumentation Development. , 2010, Analytical chemistry.

[27]  U. Justesen,et al.  Quantitative analysis of flavonols, flavones, and flavanones in fruits, vegetables and beverages by high-performance liquid chromatography with photo-diode array and mass spectrometric detection. , 1998, Journal of chromatography. A.

[28]  Simon Maher,et al.  Hand-held portable desorption atmospheric pressure chemical ionization ion source for in situ analysis of nitroaromatic explosives. , 2015, Analytical chemistry.

[29]  R. Noll,et al.  Analytical performance of a miniature cylindrical ion trap mass spectrometer. , 2002, Analytical chemistry.

[30]  W. Kolch,et al.  Capillary electrophoresis-mass spectrometry as a powerful tool in clinical diagnosis and biomarker discovery. , 2005, Mass spectrometry reviews.

[31]  R. Cooks,et al.  Miniature mass analyzers , 2000, Journal of mass spectrometry : JMS.

[32]  Qingyu Song,et al.  Handheld rectilinear ion trap mass spectrometer. , 2006, Analytical chemistry.

[33]  W. Xu,et al.  Development of a miniature mass spectrometer with continuous atmospheric pressure interface. , 2015, The Analyst.

[34]  Jin-Ming Lin,et al.  Development, characterization, and application of paper spray ionization. , 2010, Analytical chemistry.

[35]  Zheng Ouyang,et al.  Miniature cylindrical ion trap mass spectrometer. , 2002, Analytical chemistry.