A 2 nd Order Harmonic Compensation Method for Wind Power System Using a PR Controller

This paper proposes a compensation method for the 2 nd -order harmonic of single-phase grid-connected wind power generation systems. Theoretically, a single-phase grid-connected inverter system has no choice but to cause the 2 nd -order harmonic to DC-link voltage. The reference active current is affected by the DC-link voltage. The output current from the reference active current is distorted by the 1 st and 3 rd -order harmonic. The proposed method can compensate, conveniently, the reference active current with the 2 nd -order harmonic. To reduce the 2 nd -order ripple in the reference active current, proposed method takes a PR controller as a feed-forward compensator. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulation and experimental results agree well with the theoretical analysis.

[1]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady-state error , 2003 .

[2]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[3]  Kyo-Beum Lee,et al.  Hardware Simulator Development for a 3-Parallel Grid-Connected PMSG Wind Power System , 2010 .

[4]  Jang-Mok Kim,et al.  Simple Estimation Scheme for Initial Rotor Position and Inductances for Effective MTPA-Operation in Wind-Power Systems using an IPMSM , 2010 .

[5]  Poh Chiang Loh,et al.  High-performance harmonic extraction algorithm for a 25 kV traction power quality conditioner , 2004 .

[6]  Frede Blaabjerg,et al.  Stability improvement of induction generator-based wind turbine systems , 2007 .

[7]  Guo Xiaoqiang,et al.  A Single-Phase Grid-Connected Inverter System With Zero Steady-State Error , 2006, 2006 CES/IEEE 5th International Power Electronics and Motion Control Conference.

[8]  R. Bharanikumar,et al.  Boost chopper circuit for low power wind turbine driven PM synchronous generator , 2007, 2007 International Conference on Intelligent and Advanced Systems.

[9]  Chennai Salim,et al.  Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances , 2013 .

[10]  Keiichi Takahashi,et al.  A restarting method of an induction motor speed-sensorless vector control system for a small-sized wind turbine power generator system , 2009, 2009 International Conference on Electrical Machines and Systems.

[11]  M. Liserre,et al.  Reactive Power Control for Improving Wind Turbine System Behavior Under Grid Faults , 2009, IEEE Transactions on Power Electronics.

[12]  Adel M. Sharaf,et al.  Power efficient PID controller of wind driven induction generation single-phase induction motors for electric energy saving applications , 2010, 2010 IEEE Electrical Power & Energy Conference.

[13]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[14]  Hanju Cha,et al.  Mitigation of Low Frequency AC Ripple in Single-Phase Photovoltaic Power Conditioning Systems , 2010 .

[15]  Kyo-Beum Lee,et al.  Stability Improvement of Distributed Power Generation Systems with an LCL-Filter Using Gain Scheduling Based on Grid Impedance Estimations , 2011 .

[16]  Kyo-Beum Lee,et al.  Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller , 2012 .