Chemical analysis in saliva and the search for salivary biomarkers - a tutorial review.
暂无分享,去创建一个
Richard G Compton | Christopher Batchelor-McAuley | R. Compton | Korbua Chaisiwamongkhol | C. Batchelor‐McAuley | Kamonwad Ngamchuea | Korbua Chaisiwamongkhol | Kamonwad Ngamchuea | Christopher Batchelor‐McAuley
[1] Aaas News,et al. Book Reviews , 1893, Buffalo Medical and Surgical Journal.
[2] R. Sarpong,et al. Bio-inspired synthesis of xishacorenes A, B, and C, and a new congener from fuscol† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c9sc02572c , 2019, Chemical science.
[3] Richard G Compton,et al. Amperometric micro pH measurements in oxygenated saliva. , 2017, The Analyst.
[4] Richard G. Compton,et al. Supported Microwires for Electroanalysis: Sensitive Amperometric Detection of Reduced Glutathione. , 2017, Analytical chemistry.
[5] R. Compton,et al. Rapid Method for the Quantification of Reduced and Oxidized Glutathione in Human Plasma and Saliva. , 2017, Analytical chemistry.
[6] C. Banks,et al. Simultaneous Voltammetric Determination of Acetaminophen and Isoniazid (Hepatotoxicity-Related Drugs) Utilizing Bismuth Oxide Nanorod Modified Screen-Printed Electrochemical Sensing Platforms. , 2017, Analytical chemistry.
[7] E. Gil,et al. Electrochemical behavior of the cotinine at a boron-doped diamond electrode and its determination in saliva by multiple-pulse amperometry in an FIA system , 2016 .
[8] Cláudia Regina dos Santos,et al. Salivary calcium and phosphate stability in different time and temperature storage , 2016 .
[9] P. Cowen,et al. Can saliva testing replace blood measurements for health monitoring? Insights from a correlation study of salivary and whole blood glutathione in humans. , 2016, The Analyst.
[10] Seong J. Cho,et al. Disposable all-solid-state pH and glucose sensors based on conductive polymer covered hierarchical AuZn oxide. , 2016, Biosensors & bioelectronics.
[11] T. Selvaraju,et al. Synergistic effect of bimetallic Ag@Cu nanorods modified electrode for enhanced electrochemical sensing of thiocyanate ions , 2016, Research on Chemical Intermediates.
[12] S. Zaidi,et al. A review on the latest developments in nanostructure-based electrochemical sensors for glutathione , 2016 .
[13] R. Compton,et al. Electrochemical determination of free and total glutathione in human saliva samples , 2015 .
[14] B. Avcı,et al. Oxidative stress in bipolar and schizophrenia patients , 2015, Psychiatry Research.
[15] R. Compton,et al. Selective Thiol Detection in Authentic Biological Samples with the Use of Screen-printed Electrodes , 2015, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[16] R. Compton,et al. Selective electrochemical detection of thiol biomarkers in saliva using multiwalled carbon nanotube screen-printed electrodes , 2015 .
[17] R. Compton,et al. The use of cylindrical micro-wire electrodes for nano-impact experiments; facilitating the sub-picomolar detection of single nanoparticles , 2014 .
[18] Aysegul Kutluay,et al. An electrochemical sensor prepared by sonochemical one-pot synthesis of multi-walled carbon nanotube-supported cobalt nanoparticles for the simultaneous determination of paracetamol and dopamine. , 2014, Analytica chimica acta.
[19] S. Padmashree,et al. Correlation of salivary glucose, blood glucose and oral candidal carriage in the saliva of type 2 diabetics: A case-control study , 2014, Contemporary clinical dentistry.
[20] R. Compton,et al. Simultaneous Detection of Homocysteine and Cysteine in the Presence of Ascorbic Acid and Glutathione Using a Nanocarbon Modified Electrode , 2014 .
[21] Dermot Diamond,et al. A potentiometric disposable sensor strip for measuring pH in saliva , 2014 .
[22] Richard G. Compton,et al. The Use of Screen-Printed Electrodes in a Proof of Concept Electrochemical Estimation of Homocysteine and Glutathione in the Presence of Cysteine Using Catechol , 2014, Sensors.
[23] M. Deng,et al. High-sensitivity paracetamol sensor based on Pd/graphene oxide nanocomposite as an enhanced electrochemical sensing platform. , 2014, Biosensors & bioelectronics.
[24] C. Brett,et al. Simple electrochemical sensor for caffeine based on carbon and Nafion-modified carbon electrodes. , 2014, Food chemistry.
[25] Nirima Oza,et al. Salivary Creatinine Estimation as an Alternative to Serum Creatinine in Chronic Kidney Disease Patients , 2014, International journal of nephrology.
[26] Shekhar Bhansali,et al. Recent advances in cortisol sensing technologies for point-of-care application. , 2014, Biosensors & bioelectronics.
[27] S. R. Taylor,et al. The Fabrication and Calibration of an Iridium pH Micro-sensor for Biological Applications , 2014 .
[28] K. Kalcher,et al. Boron-doped diamond electrochemical sensor for sensitive determination of nicotine in tobacco products and anti-smoking pharmaceuticals , 2014 .
[29] Kristopher R. Ward,et al. Electrochemical Detection of Glutathione Using a Poly(caffeic acid) Nanocarbon Composite Modified Electrode , 2014 .
[30] L. Busch,et al. Total salivary nitrates and nitrites in oral health and periodontal disease. , 2014, Nitric oxide : biology and chemistry.
[31] G. Goodwin,et al. Altered plasma glutathione levels in bipolar disorder indicates higher oxidative stress; a possible risk factor for illness onset despite normal brain-derived neurotrophic factor (BDNF) levels , 2014, Psychological Medicine.
[32] A. Amine,et al. Carbon Black‐Modified Electrodes as Sensitive Tools for the Electrochemical Detection of Nitrite and Nitrate , 2013 .
[33] J. Raoof,et al. Electrocatalytic oxidation and selective determination of an opioid analgesic methadone in the presence of acetaminophen at a glassy carbon electrode modified with functionalized multi-walled carbon nanotubes: application for human urine, saliva and pharmaceutical samples analysis. , 2013, Colloids and surfaces. B, Biointerfaces.
[34] R. Compton,et al. Electrochemical Detection of NADH, Cysteine, or Glutathione Using a Caffeic Acid Modified Glassy Carbon Electrode , 2013 .
[35] A. Yarat,et al. Determination of Storage Time of Saliva Samples Obtained From Patients With and Without Chronic Periodontitis for the Comparison of Some Biochemical and Cytological Parameters , 2013, Journal of clinical laboratory analysis.
[36] U. Völker,et al. Comparative evaluation of saliva collection methods for proteome analysis. , 2013, Clinica chimica acta; international journal of clinical chemistry.
[37] I. Hickie,et al. In vivo glutathione levels in young persons with bipolar disorder: a magnetic resonance spectroscopy study. , 2013, Journal of psychiatric research.
[38] Luca Manetti,et al. Usefulness of salivary cortisol in the diagnosis of hypercortisolism: comparison with serum and urinary cortisol. , 2013, European journal of endocrinology.
[39] A. Kerkeni,et al. Reduced antioxidant defense systems in schizophrenia and bipolar I disorder , 2012, Progress in Neuro-Psychopharmacology and Biological Psychiatry.
[40] B. Habibi,et al. A Carbon Nanotube Modified Electrode for Determination of Caffeine by Differential Pulse Voltammetry , 2012 .
[41] Manjunatha Bs. Textbook of Dental Anatomy and Oral Physiology , 2012 .
[42] S. Ai,et al. Electrochemical determination of theophylline in foodstuff, tea and soft drinks based on urchin-like CdSe microparticles modified glassy carbon electrode. , 2012, Food chemistry.
[43] G. Mersal. Experimental and Computational Studies on the Electrochemical Oxidation of Caffeine at Pseudo Carbon Paste Electrode and Its Voltammetric Determination in Different Real Samples , 2012, Food Analytical Methods.
[44] Z. Chen,et al. Sensitive and selective detection of glutathione based on resonance light scattering using sensitive gold nanoparticles as colorimetric probes. , 2012, The Analyst.
[45] A. Yamaguchi,et al. Uric acid concentration in saliva and its changes with the patients receiving treatment for hyperuricemia , 2012, Metabolomics.
[46] Tingting Liu,et al. A novel electrochemical sensor based on molecularly imprinted polymers for caffeine recognition and detection , 2012, Journal of Solid State Electrochemistry.
[47] B. Ye,et al. Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion , 2012, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[48] R. Compton,et al. Electrochemical determination of glutathione: a review. , 2012, The Analyst.
[49] Derek G Rodeback,et al. Salivary uric acid as a noninvasive biomarker of metabolic syndrome , 2012, Diabetology & Metabolic Syndrome.
[50] X. Xia,et al. Electrochemical sensor based on nitrogen doped graphene: simultaneous determination of ascorbic acid, dopamine and uric acid. , 2012, Biosensors & bioelectronics.
[51] Joel G Pounds,et al. Electrochemical immunoassay of cotinine in serum based on nanoparticle probe and immunochromatographic strip. , 2012, Analytica chimica acta.
[52] Wensheng Yang,et al. A high performance electrochemical sensor for acetaminophen based on single-walled carbon nanotube-graphene nanosheet hybrid films , 2012 .
[53] Tomayess Issa,et al. Glassy carbon electrode modified with hybrid films containing inorganic molybdate anions trapped in organic matrices of chitosan and ionic liquid for the amperometric sensing of phosphate at neutral pH , 2011 .
[54] J. Giebułtowicz,et al. Comparison of antioxidant enzymes activity and the concentration of uric acid in the saliva of patients with oral cavity cancer, odontogenic cysts and healthy subjects. , 2011, Journal of oral pathology & medicine : official publication of the International Association of Oral Pathologists and the American Academy of Oral Pathology.
[55] Yang Fan,et al. Electrochemical behavior and voltammetric determination of paracetamol on Nafion/TiO2-graphene modified glassy carbon electrode. , 2011, Colloids and surfaces. B, Biointerfaces.
[56] R. Goyal,et al. Electrochemical sensor for the simultaneous determination of caffeine and aspirin in human urine samples , 2011 .
[57] Chia-Liang Sun,et al. The simultaneous electrochemical detection of ascorbic acid, dopamine, and uric acid using graphene/size-selected Pt nanocomposites. , 2011, Biosensors & bioelectronics.
[58] Jun-Feng Wang,et al. Decreased levels of glutathione, the major brain antioxidant, in post-mortem prefrontal cortex from patients with psychiatric disorders. , 2011, The international journal of neuropsychopharmacology.
[59] A. Daneshfar,et al. Determination of nicotine, anabasine, and cotinine in urine and saliva samples using single-drop microextraction. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[60] P. Breslin,et al. Individual Differences in AMY1 Gene Copy Number, Salivary α-Amylase Levels, and the Perception of Oral Starch , 2010, PloS one.
[61] Jun Liu,et al. A graphene-based electrochemical sensor for sensitive detection of paracetamol. , 2010, Talanta.
[62] B. J. Venton,et al. Review: Carbon nanotube based electrochemical sensors for biomolecules. , 2010, Analytica chimica acta.
[63] Mehmet Aslanoglu,et al. Voltammetric selectivity conferred by the modification of electrodes using conductive porous layers or films: The oxidation of dopamine on glassy carbon electrodes modified with multiwalled carbon nanotubes , 2010 .
[64] R. Compton,et al. Effects of thin-layer diffusion in the electrochemical detection of nicotine on basal plane pyrolytic graphite (BPPG) electrodes modified with layers of multi-walled carbon nanotubes (MWCNT-BPPG) , 2010 .
[65] Guobao Xu,et al. Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode. , 2009, Biosensors & bioelectronics.
[66] Rashid O. Kadara,et al. Metallic Free Carbon Nanotube Cluster Modified Screen Printed Electrodes for the Sensing of Nicotine in Artificial Saliva , 2009 .
[67] E. Farjami,et al. Simultaneous electrochemical determination of glutathione and glutathione disulfide at a nanoscale copper hydroxide composite carbon ionic liquid electrode. , 2009, Analytical chemistry.
[68] Xiaoya Hu,et al. Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrode , 2009 .
[69] Y. Tsai,et al. Low potential detection of nicotine at multiwalled carbon nanotube–alumina-coated silica nanocomposite , 2009 .
[70] Liping Guo,et al. Application of electrochemical properties of ordered mesoporous carbon to the determination of glutathione and cysteine. , 2009, Analytical biochemistry.
[71] K. Ho,et al. Detection of nicotine based on molecularly imprinted TiO2-modified electrodes. , 2009, Analytica chimica acta.
[72] Richard G Compton,et al. Sensitive adsorptive stripping voltammetric determination of paracetamol at multiwalled carbon nanotube modified basal plane pyrolytic graphite electrode. , 2008, Analytica chimica acta.
[73] Ł. Minarowski,et al. Thiocyanate concentration in saliva of cystic fibrosis patients. , 2008, Folia histochemica et cytobiologica.
[74] M. Navazesh,et al. Measuring salivary flow: challenges and opportunities. , 2008, Journal of the American Dental Association.
[75] S. Horie,et al. Diagnostic significance of salivary testosterone measurement revisited: using liquid chromatography/mass spectrometry and enzyme-linked immunosorbent assay , 2008 .
[76] Patrícia Del Vigna de Almeida,et al. Saliva composition and functions: a comprehensive review. , 2008, The journal of contemporary dental practice.
[77] F. Botrè,et al. Parallel analysis of stimulants in saliva and urine by gas chromatography/mass spectrometry: perspectives for "in competition" anti-doping analysis. , 2008, Analytica chimica acta.
[78] D. Weening,et al. Sample Stability and Protein Composition of Saliva: Implications for Its Use as a Diagnostic Fluid , 2008, Biomarker insights.
[79] S. Vasikaran,et al. Correlation of paired plasma and saliva paracetamol levels following deliberate self-poisoning with paracetamol (The Salivary Paracetamol In Toxicology [SPIT] study) , 2008, Clinical toxicology.
[80] R. Matsuo,et al. Salivary secretion, taste and hyposalivation. , 2007, Journal of oral rehabilitation.
[81] G. Paludetti,et al. Salivary glutathione and uric acid levels in patients with head and neck squamous cell carcinoma , 2007, Head & neck.
[82] A. Mannocci,et al. Bile Acids and Total Bilirubin Detection in Saliva of Patients Submitted to Gastric Surgery and in Particular to Subtotal Billroth II Resection , 2007, Annals of surgery.
[83] R. Nagler,et al. Relationship of flow rate, uric acid, peroxidase, and superoxide dismutase activity levels with complications in diabetic patients: can saliva be used to diagnose diabetes? , 2007, Antioxidants & redox signaling.
[84] Z. Červinková,et al. Determination of reduced and oxidized glutathione in biological samples using liquid chromatography with fluorimetric detection. , 2007, Journal of pharmaceutical and biomedical analysis.
[85] Wanzhi. Wei,et al. Determination of trace thiocyanate with nano-silver coated multi-walled carbon nanotubes modified glassy carbon electrode. , 2007, Analytica chimica acta.
[86] F. Tajabadi,et al. Simultaneous determination of dopamine, ascorbic acid, and uric acid using carbon ionic liquid electrode. , 2006, Analytical biochemistry.
[87] M. Rauh,et al. Influence of commercial collection devices for saliva on the reliability of salivary steroids analysis , 2006, Steroids.
[88] C. Arana,et al. Parameters of oxidative stress in saliva from diabetic and parenteral drug addict patients. , 2006, Journal of oral pathology & medicine : official publication of the International Association of Oral Pathologists and the American Academy of Oral Pathology.
[89] Wanzhi. Wei,et al. Application of a novel electrosynthesized polydopamine-imprinted film to the capacitive sensing of nicotine , 2006, Analytical and bioanalytical chemistry.
[90] Ann Marie McCarthy,et al. Strategies for salivary cortisol collection and analysis in research with children. , 2006, Applied nursing research : ANR.
[91] Heyou Han,et al. Chemiluminescence Method for the Determination of Glutathione in Human Serum Using the Ru(phen)32+ – KMnO4 System , 2006 .
[92] Douglas A. Granger,et al. Bacteria in the oral mucosa and its effects on the measurement of cortisol, dehydroepiandrosterone, and testosterone in saliva , 2006, Hormones and Behavior.
[93] R. Mehvar,et al. Rapid determination of reduced and oxidized glutathione levels using a new thiol-masking reagent and the enzymatic recycling method: application to the rat liver and bile samples , 2006, Analytical and bioanalytical chemistry.
[94] R. Hintsche,et al. Micromachined sensor for lactate monitoring in saliva. , 2006, Biosensors & bioelectronics.
[95] F. Ricci,et al. Glutathione amperometric detection based on a thiol–disulfide exchange reaction , 2006 .
[96] Li Jiang,et al. An In Situ Copper Plated Boron‐Doped Diamond Microelectrode Array for the Sensitive Electrochemical Detection of Nitrate , 2005 .
[97] D. Pang,et al. Electrochemical oxidation of theophylline at multi-wall carbon nanotube modified glassy carbon electrodes , 2005 .
[98] L. Martens,et al. Review: The physiology of saliva and transfer of drugs into saliva. , 2005, Forensic science international.
[99] B. Arjmandi,et al. Saliva versus serum estradiol: Implications for research studies using postmenopausal women , 2005, Progress in Neuro-Psychopharmacology and Biological Psychiatry.
[100] A M Hansen,et al. Long‐term stability of salivary cortisol , 2005, Scandinavian journal of clinical and laboratory investigation.
[101] G. D’Onofrio,et al. The saliva strip test is an accurate method to determine blood alcohol concentration in trauma patients. , 2004, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.
[102] F. C. Giacomelli,et al. Behavior of a Co-Cr-Mo biomaterial in simulated body fluid solutions studied by electrochemical and surface analysis techniques , 2004 .
[103] R. Nagler,et al. Biochemical analysis of saliva and taste acuity evaluation in patients with burning mouth syndrome, xerostomia and/or gustatory disturbances. , 2004, Archives of oral biology.
[104] Jing‐Juan Xu,et al. Determination of Theophylline in Drugs and Tea on Nanosized Cobalt Phthalocyanine Particles Modified Carbon Paste Electrode , 2004 .
[105] D. Koh,et al. Effects of storage time on stability of salivary immunoglobulin A and lysozyme. , 2003, Clinica chimica acta; international journal of clinical chemistry.
[106] K. Zou,et al. Correlation and simple linear regression. , 2003, Radiology.
[107] J. Scott,et al. Effects of Sample Collection and Storage Methods on Antipneumococcal Immunoglobulin A in Saliva , 2003, Clinical Diagnostic Laboratory Immunology.
[108] T. Ohsaka,et al. Gold nanoparticle arrays for the voltammetric sensing of dopamine , 2003 .
[109] P. Bennett,et al. An investigation into the relationship between salivary cortisol, stress, anxiety and depression , 2003, Biological Psychology.
[110] L. Deiana,et al. Ultrarapid capillary electrophoresis method for the determination of reduced and oxidized glutathione in red blood cells , 2002, Electrophoresis.
[111] Charles S Henry,et al. The analysis of uric acid in urine using microchip capillary electrophoresis with electrochemical detection , 2002, Electrophoresis.
[112] Dariusz Zuba,et al. Saliva as an alternative specimen for alcohol determination in the human body. , 2002, Polish journal of pharmacology.
[113] J. Groenink,et al. Lactoferrin, amylase and mucin MUC5B and their relation to the oral microflora in hyposalivation of different origins. , 2001, Oral microbiology and immunology.
[114] K. Shiu,et al. Determination of Uric Acid at Electrochemically Activated Glassy Carbon Electrode , 2001 .
[115] M. Rauh,et al. Stability of salivary steroids: the influences of storage, food and dental care , 2001, Steroids.
[116] Danila Moscone,et al. New electrochemical sensors for detection of nitrites and nitrates , 2001 .
[117] E. Cone,et al. Detection of marijuana use by oral fluid and urine analysis following single-dose administration of smoked and oral marijuana. , 2001, Journal of analytical toxicology.
[118] J. David,et al. Quantification of reduced and oxidized glutathione in whole blood samples by capillary electrophoresis. , 2001, Clinical chemistry.
[119] J. Gal,et al. About a synthetic saliva for in vitro studies. , 2001, Talanta.
[120] E. Shirtcliff,et al. Use of salivary biomarkers in biobehavioral research: cotton-based sample collection methods can interfere with salivary immunoassay results , 2001, Psychoneuroendocrinology.
[121] N. Lawrence,et al. Electrochemical detection of thiols in biological media. , 2001, Talanta.
[122] C. Alm,et al. Evaluation of caffeine as an in vivo probe for CYP1A2 using measurements in plasma, saliva, and urine. , 2000, Therapeutic drug monitoring.
[123] J. Pirkle,et al. Comparison of serum and salivary cotinine measurements by a sensitive high-performance liquid chromatography-tandem mass spectrometry method as an indicator of exposure to tobacco smoke among smokers and nonsmokers. , 2000, Journal of analytical toxicology.
[124] S. Parkkila,et al. Salivary carbonic anhydrase isoenzyme VI , 1999, The Journal of physiology.
[125] J. Zen,et al. Determination of theophylline in tea and drug formulation using a Nafion(R)/lead-ruthenium oxide pyrochlore chemically modified electrode. , 1999, Talanta.
[126] M. Cardosi,et al. Evaluation of phenolic assays for the detection of nitrite. , 1999, Talanta.
[127] A. Booth,et al. Assessing dehydroepiandrosterone in saliva: a simple radioimmunoassay for use in studies of children, adolescents and adults , 1999, Psychoneuroendocrinology.
[128] G R Bentley,et al. Salivary estradiol and progesterone levels in conception and nonconception cycles in women: evaluation of a new assay for salivary estradiol. , 1999, Fertility and sterility.
[129] M. Larsen,et al. Individual variations of pH, buffer capacity, and concentrations of calcium and phosphate in unstimulated whole saliva. , 1999, Archives of oral biology.
[130] B. Levallois,et al. In vitro fluoride release from restorative materials in water versus artificial saliva medium (SAGF). , 1998, Dental materials : official publication of the Academy of Dental Materials.
[131] P. Marsh,et al. Analysis of pH–Driven Disruption of Oral Microbial Communities in vitro , 1998, Caries Research.
[132] D. Malamud,et al. Detection of Human Immunodeficiency Virus Antibodies in Oral Fluids , 1998, Clinical Diagnostic Laboratory Immunology.
[133] Dean P. Jones,et al. Glutathione measurement in human plasma. Evaluation of sample collection, storage and derivatization conditions for analysis of dansyl derivatives by HPLC. , 1998, Clinica chimica acta; international journal of clinical chemistry.
[134] Margarita Pérez,et al. Saliva Composition and Exercise , 1998, Sports medicine.
[135] Brian Owen-Smith,et al. Salivary urate in gout, exercise, and diurnal variation , 1998, The Lancet.
[136] F. Ochsendorf,et al. Glutathione in spermatozoa and seminal plasma of infertile men. , 1998, Human reproduction.
[137] Jyh-Myng Zen and,et al. A Selective Voltammetric Method for Uric Acid and Dopamine Detection Using Clay-Modified Electrodes , 1997 .
[138] B. Darvell,et al. Artificial salivas for in vitro studies of dental materials. , 1997, Journal of dentistry.
[139] D. Dawson,et al. Salivary Melatonin as a Circadian Phase Marker: Validation and Comparison to Plasma Melatonin , 1997, Journal of biological rhythms.
[140] O. Simell,et al. Salivary Cholesterol of Healthy Adults in Relation to Serum Cholesterol Concentration and Oral Health , 1997, Journal of dental research.
[141] M. Bates,et al. Immediate, quantitative estimation of blood alcohol concentration from saliva. , 1997, Journal of studies on alcohol.
[142] C. Hsueh,et al. Surface and kinetic enhancement of selectivity and sensitivity in analysis with fast scan voltammetry at scan rates above 1000 V/s , 1997 .
[143] E. Garrido,et al. A new approach to the assessment of anaerobic metabolism: measurement of lactate in saliva. , 1996, British journal of sports medicine.
[144] A. Slomiany,et al. Salivary mucins in oral mucosal defense. , 1996, General pharmacology.
[145] E. Cone,et al. Comparison of heroin and cocaine concentrations in saliva with concentrations in blood and plasma. , 1995, Journal of analytical toxicology.
[146] S. Moss. Clinical implications of recent advances in salivary research. , 1995, Journal of esthetic dentistry.
[147] C. Kirschbaum,et al. Salivary cortisol in psychoneuroendocrine research: Recent developments and applications , 1994, Psychoneuroendocrinology.
[148] E. Cone,et al. Simultaneous assay of cocaine, heroin and metabolites in hair, plasma, saliva and urine by gas chromatography-mass spectrometry. , 1994, Journal of chromatography. B, Biomedical applications.
[149] E D Levin,et al. Saliva Nicotine as an Index of Plasma Levels in Nicotine Skin Patch Users , 1993, Therapeutic drug monitoring.
[150] R. Haeckel. Factors Influencing the Saliva/Plasma Ratio of Drugs , 1993, Annals of the New York Academy of Sciences.
[151] I. Mandel. Salivary Diagnosis: Promises, Promises , 1993, Annals of the New York Academy of Sciences.
[152] G. Read. Status Report on Measurement of Salivary Estrogens and Androgens , 1993, Annals of the New York Academy of Sciences.
[153] M. Traisnel,et al. Electrochemical behaviour of titanium and dental alloys in artificial saliva , 1993 .
[154] E. Silbergeld. New Approaches to Monitoring Environmental Neurotoxins a , 1993, Annals of the New York Academy of Sciences.
[155] M. Navazesh,et al. Methods for Collecting Saliva , 1993, Annals of the New York Academy of Sciences.
[156] D. Goodman. Fundamental Principles Involved in Developing a New Saliva‐based Diagnostic Test , 1993, Annals of the New York Academy of Sciences.
[157] John T. Wilson. Clinical Correlates of Drugs in Saliva , 1993, Annals of the New York Academy of Sciences.
[158] M. Levine. Salivary Macromolecules , 1993, Annals of the New York Academy of Sciences.
[159] R. Frerichs,et al. Comparison of saliva and serum for HIV surveillance in developing countries , 1992, The Lancet.
[160] R. McCreery,et al. Effects of Redox System Structure on Electron-Transfer Kinetics at Ordered Graphite and Glassy Carbon Electrodes , 1992 .
[161] Y. Israel,et al. Characteristics of a new urine, serum, and saliva alcohol reagent strip. , 1992, Alcoholism, clinical and experimental research.
[162] R. Coates,et al. Comparison of saliva and blood for human immunodeficiency virus prevalence testing. , 1991, The Journal of infectious diseases.
[163] G. Cole,et al. In vitro inhibition of HIV-1 infectivity by human salivas. , 1990, AIDS research and human retroviruses.
[164] G. Paumgartner,et al. Assessment of hepatic function. Comparison of caffeine clearance in serum and saliva during the day and at night. , 1990, Journal of hepatology.
[165] B. Neuschwander‐Tetri,et al. Glutathione measurement by high-performance liquid chromatography separation and fluorometric detection of the glutathione-orthophthalaldehyde adduct. , 1989, Analytical biochemistry.
[166] E. Cone,et al. Correlation of saliva cocaine levels with plasma levels and with pharmacologic effects after intravenous cocaine administration in human subjects. , 1988, Journal of analytical toxicology.
[167] J. Pickup,et al. Salivary Insulin in Normal and Type I Diabetic Subjects , 1988, Diabetes Care.
[168] Y. El‐Sayed,et al. HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC ANALYSIS OF CAFFEINE CONCENTRATIONS IN PLASMA AND SALIVA , 1988, Journal of clinical pharmacy and therapeutics.
[169] D. Rubinow,et al. Salivary cortisol: A practical method for evaluation of adrenal function , 1988, Biological Psychiatry.
[170] Rose Marie Pangborn,et al. The effect of oral stimulation on human parotid salivary flow rate and alpha-amylase secretion , 1987, Physiology & Behavior.
[171] A. Tal,et al. Monitoring theophylline therapy using citric acid-stimulated saliva in infants and children with asthma. , 1987, Pediatrics.
[172] J. Redman,et al. THE CORRELATION BETWEEN SERUM AND SALIVARY MELATONIN CONCENTRATIONS AND URINARY 6‐HYDROXYMELATONIN SULPHATE EXCRETION RATES: TWO NON‐INVASIVE TECHNIQUES FOR MONITORING HUMAN CIRCADIAN RHYTHMICITY , 1987, Clinical endocrinology.
[173] P. Brodin,et al. Parotid salivary flow in response to mechanical and gustatory stimulation in man. , 1987, Acta physiologica Scandinavica.
[174] T. Chard,et al. Saliva Levels of Oestradiol and Progesterone in Relation to Non-Protein-Bound Concentrations in Blood During Late Pregnancy , 1987, Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme.
[175] M. New,et al. Morning salivary 17-hydroxyprogesterone is a useful screening test for nonclassical 21-hydroxylase deficiency. , 1987, The Journal of clinical endocrinology and metabolism.
[176] R. Crystal,et al. Normal alveolar epithelial lining fluid contains high levels of glutathione. , 1987, Journal of applied physiology.
[177] G. Joplin,et al. Direct assay for testosterone in saliva: relationship with a direct serum free testosterone assay. , 1987, Clinica chimica acta; international journal of clinical chemistry.
[178] V. James,et al. THE RELATIONSHIP BETWEEN SALIVARY ALDOSTERONE AND PLASMA FREE ALDOSTERONE CONCENTRATIONS , 1986, Clinical endocrinology.
[179] E. Nieschlag,et al. Estradiol in saliva for monitoring follicular stimulation in an in vitro fertilization program. , 1985, Fertility and sterility.
[180] D. Forman,et al. Nitrates, nitrites and gastric cancer in Great Britain , 1985, Nature.
[181] R. Perry,et al. Saliva Lithium Levels in Children: Their Use in Monitoring Serum Lithium Levels and Lithium Side Effects , 1984, Journal of clinical psychopharmacology.
[182] R. Bhatnagar,et al. Salivary viscosity and lubrication: influence of pH and calcium. , 1984, Scandinavian journal of dental research.
[183] L. Granit,et al. Relationship between caffeine concentrations in plasma and saliva , 1984, Clinical pharmacology and therapeutics.
[184] C. Flamigni,et al. Elisa for salivary and plasma estriol in pregnancy , 1984, Steroids.
[185] F. Khan-dawood,et al. Salivary and plasma bound and "free" testosterone in men and women. , 1984, American journal of obstetrics and gynecology.
[186] R F Vining,et al. Salivary Cortisol: A Better Measure of Adrenal Cortical Function than Serum Cortisol , 1983, Annals of clinical biochemistry.
[187] F. Khan-dawood,et al. Progesterone and estradiol in the saliva and plasma during the menstrual cycle. , 1983, American journal of obstetrics and gynecology.
[188] G. Hughes,et al. IgA and IgM rheumatoid factors in serum, saliva and other secretions: relationship to immunoglobulin ratios in systemic sicca syndrome and rheumatoid arthritis. , 1983, Clinical and experimental immunology.
[189] N. Novak,et al. Salivary unconjugated estriol levels in normal third trimester pregnancy — Direct correlation with serum levels , 1983, Steroids.
[190] E. Nieschlag,et al. Salivary testosterone in men: further evidence of a direct correlation with free serum testosterone. , 1981, The Journal of clinical endocrinology and metabolism.
[191] Hiramatsu Ryoji,et al. Use of saliva for monitoring unbound free cortisol levels in serum , 1981 .
[192] D. J. Reed,et al. High-performance liquid chromatography analysis of nanomole levels of glutathione, glutathione disulfide, and related thiols and disulfides. , 1980, Analytical biochemistry.
[193] O. Griffith,et al. Determination of glutathione and glutathione disulfide using glutathione reductase and 2-vinylpyridine. , 1980, Analytical biochemistry.
[194] R. Walker,et al. SALIVARY 17α‐HYDROXYPROGESTERONE IN CONGENITAL ADRENAL HYPERPLASIA , 1979 .
[195] M. New,et al. The Biologic Significance of the Aldosterone Concentration in Saliva , 1979, Pediatric Research.
[196] P. Baumann,et al. Lithium concentrations in saliva, plasma and red blood cells of patients given lithium acetate , 1978, Acta psychiatrica Scandinavica.
[197] J.-M. Meyer. Corrosion resistance of nickel-chromium dental casting alloys , 1978 .
[198] J. Orcutt,et al. Reliability of salivary theophylline as a guide to plasma theophylline levels. , 1977, American journal of diseases of children.
[199] I. Leppik,et al. Salivary levels of anticonvulsants , 1977, Neurology.
[200] H. Kupferberg,et al. Diphenylhydantoin, Phenobarbital, and Primidone in Saliva, Plasma, and Cerebrospinal Fluid , 1975, Epilepsia.
[201] H. D. Schwartz,et al. Serum ionized calcium by electrodes: new technology and methodology. , 1975, Clinica chimica acta; international journal of clinical chemistry.
[202] C. Gorodetzky,et al. Validity of screening methods for drugs of abuse in biological fluids; II. Heroin in plasma and saliva , 1974, Clinical pharmacology and therapeutics.
[203] G. Levy,et al. Indirect plasma-theophylline monitoring in asthmatic children by determination of theophylline concentration in saliva. , 1974, Pediatrics.
[204] J. F. Bates,et al. Ascorbic acid status in man: measurements of salivary, plasma and white blood cell concentration. , 1972, Archives of oral biology.
[205] F. Tietze. Enzymic method for quantitative determination of nanogram amounts of total and oxidized glutathione: applications to mammalian blood and other tissues. , 1969, Analytical biochemistry.
[206] H Güntherberg,et al. The true oxidized glutathione content of red blood cells obtained by new enzymic and paper chromatographic methods. , 1966, Analytical biochemistry.
[207] S. Wong,et al. GLASS ELECTRODE MEASUREMENTS OF BLOOD SODIUM AND POTASSIUM IN MAN. , 1963, Journal of applied physiology.
[208] T. F. Maliszewski,et al. True and apparent thiocyanate in body fluids of smokers and nonsmokers. , 1955, Journal of applied physiology.
[209] M. Somogyi. MICROMETHODS FOR THE ESTIMATION OF DIASTASE , 1938 .
[210] W. Hager,et al. and s , 2019, Shallow Water Hydraulics.
[211] G. Maupomé,et al. Salivary Parameters (Salivary Flow, pH and Buffering Capacity) in Stimulated Saliva of Mexican Elders 60 Years Old and Older. , 2014, The West Indian medical journal.
[212] P. Cowen,et al. Cortical glutathione levels in young people with bipolar disorder: a pilot study using magnetic resonance spectroscopy , 2013, Psychopharmacology.
[213] Joseph Wang,et al. Wearable Electrochemical Sensors and Biosensors: A Review , 2013 .
[214] W. Marsden. I and J , 2012 .
[215] D. Wong,et al. Collection, storage, and processing of saliva samples for downstream molecular applications. , 2010, Methods in molecular biology.
[216] J. Chicharro,et al. Homogeneity and stability studies on sodium, calcium, magnesium, and manganese in human saliva , 2007, Biological Trace Element Research.
[217] Bruce J. Baum,et al. The functions of saliva , 2005, Dysphagia.
[218] B. Erens,et al. Measuring nicotine intake in population surveys: comparability of saliva cotinine and plasma cotinine estimates. , 2003, Nicotine & tobacco research : official journal of the Society for Research on Nicotine and Tobacco.
[219] A. Bardow,et al. The buffer capacity and buffer systems of human whole saliva measured without loss of CO2. , 2000, Archives of oral biology.
[220] S. Yoshida,et al. Serum Lysozyme Levels and Clinical Features of Sarcoidosis , 1999, Lung.
[221] R. Morriss,et al. A comparison of salivary cortisol in chronic fatigue syndrome, community depression and healthy controls. , 1998, Journal of affective disorders.
[222] J. Richie,et al. Blood glutathione concentrations in a large-scale human study. , 1996, Clinical chemistry.
[223] T. Ohzeki,et al. Salivary testosterone concentrations in prepubertal and pubertal males: comparison with total and free plasma testosterone. , 1991, Hormone research.
[224] T. Porkka-Heiskanen,et al. Correlation between salivary and serum melatonin: dependence on serum melatonin levels. , 1990, Journal of pineal research.
[225] E. Cone,et al. Confirmation of cocaine in human saliva after intravenous use. , 1987, Journal of analytical toxicology.
[226] L. von Knorring,et al. Saliva secretion rate and saliva composition as a model to determine the effect of antidepressant drugs on cholinergic and noradrenergic transmission. , 1986, Neuropsychobiology.
[227] C. Knott,et al. Do saliva concentrations predict plasma unbound theophylline concentrations? A problem re-examined. , 1984, British journal of clinical pharmacology.
[228] J. Evans,et al. Salivary estriol concentrations during normal pregnancies, and a comparison with plasma estriol. , 1984, Clinical chemistry.
[229] C. Knott,et al. The place of saliva in antiepileptic drug monitoring. , 1984, Therapeutic drug monitoring.
[230] J. Fiet,et al. Physiological and pathological variations in saliva cortisol. , 1982, Hormone research.
[231] E. Hellwig,et al. Fluoride taken up by plaque, by the underlying enamel and by clean enamel from three fluoride compounds in vitro. , 1982, Caries research.
[232] R. Ouvrier,et al. Salivary Anticonvulsant Levels in Children: A Comparison of Methods , 1981, Therapeutic Drug Monitoring.
[233] J. Valentine,et al. Detection of Marijuana Use in Human Saliva Using a Fluorometric Assay Based on Cannabinol Decomposition , 1979 .
[234] R. Shellis. A synthetic saliva for cultural studies of dental plaque. , 1978, Archives of oral biology.