Fault Protection Strategy and Switching Overvoltage in a ±500 kV MMC-HVDC Grid

The Zhangbei ±500 kV modular multi-level converters (MMC)-based high voltage direct current (HVDC) project to be built in China will use overhead transmission lines with dc circuit breakers (DCCBs). However, the operating characteristics of DCCBs are still not clear. In this paper, a detailed hybrid DCCB model and the fault protection strategy are built to study the influence of switching overvoltage. The results indicate that fault protection strategy can protect the equipment and causes the overvoltages changing based on the fault location. For the fault without protection, the overvoltage of three-phase grounding fault at the valve side of converter is the largest, which is 1295.2 kV (2.6 pu). For the fault with protection, the overvoltage of line-to-line fault is the largest, which is 1206.8 kV (2.41 pu). The theoretical analysis indicates that the outlet voltage of the converter increases when the DCCBs open because it is the superposition of the voltage of the line reactance and the residual voltage of the arrester, which is consistent with simulation analysis. The results can provide references for the application of DCCBs and construction of MMC-HVDC grids.

[1]  Athula D. Rajapakse,et al.  Fault Detection and Interruption in an Earthed HVDC Grid Using ROCOV and Hybrid DC Breakers , 2015, IEEE Transactions on Power Delivery.

[2]  Xu Zhen,et al.  VSC-HVDC Technology Suitable for Bulk Power Overhead Line Transmission , 2014 .

[3]  Yu Pan-Pan,et al.  Analysis of Submodule Overcurrent Caused by DC Pole-to-pole Fault in Modular Multilevel Converter HVDC System , 2011 .

[4]  Jin Yang,et al.  Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables , 2012, IEEE Transactions on Industrial Electronics.

[5]  Y Du Parameter Designing of Current Limiting DC Hybrid Circuit Breaker Based on Combinatorial Electronic Switch , 2015 .

[6]  Staffan Norrga,et al.  Efficient modeling of an MMC-based multiterminal DC system employing hybrid HVDC breakers , 2016, 2016 IEEE Power and Energy Society General Meeting (PESGM).

[7]  Tao Yuan,et al.  Transient Characteristics Under Ground and Short-Circuit Faults in a ${\pm \text{500}\,\text{kV}}$ MMC-Based HVDC System With Hybrid DC Circuit Breakers , 2018, IEEE Transactions on Power Delivery.

[8]  Weinan Wang,et al.  Research and application on multi-terminal and DC grids based on VSC-HVDC technology in China , 2017 .

[9]  Xu Shukai Analysis on the Main Wiring of Nan’ao VSC-HVDC Tranmission System , 2012 .

[10]  Wu Yanan,et al.  A Novel Design of High-voltage DC Circuit Breaker in HVDC Flexible Transmission Grid , 2013 .

[11]  Wang Yi,et al.  Application of High Voltage DC Circuit Breaker in Zhoushan VSC-HVDC Transmission Project , 2018 .

[12]  Christian M. Franck,et al.  Fault Current Interruption in Multiterminal HVDC Networks , 2016, IEEE Transactions on Power Delivery.

[13]  唐珂,et al.  High-voltage direct-current circuit breaker , 2015 .

[14]  Wei Xiaoguang,et al.  Multi-terminal HVDC and DC-grid Technology , 2013 .

[15]  Zheng Xu,et al.  Assembly HVDC Breaker for HVDC Grids With Modular Multilevel Converters , 2017, IEEE Transactions on Power Electronics.

[16]  Wenhua Liu,et al.  Protection of Nonpermanent Faults on DC Overhead Lines in MMC-Based HVDC Systems , 2013, IEEE Transactions on Power Delivery.

[17]  Zhao Chengyon,et al.  DC Pole-to-ground Fault Characteristic Analysis and Converter Fault Recovery Strategy of MMC-HVDC , 2014 .