High-performance time-resolved fluorescence by direct waveform recording.

We describe a high-performance time-resolved fluorescence (HPTRF) spectrometer that dramatically increases the rate at which precise and accurate subnanosecond-resolved fluorescence emission waveforms can be acquired in response to pulsed excitation. The key features of this instrument are an intense (1 μJ/pulse), high-repetition rate (10 kHz), and short (1 ns full width at half maximum) laser excitation source and a transient digitizer (0.125 ns per time point) that records a complete and accurate fluorescence decay curve for every laser pulse. For a typical fluorescent sample containing a few nanomoles of dye, a waveform with a signal/noise of about 100 can be acquired in response to a single laser pulse every 0.1 ms, at least 10(5) times faster than the conventional method of time-correlated single photon counting, with equal accuracy and precision in lifetime determination for lifetimes as short as 100 ps. Using standard single-lifetime samples, the detected signals are extremely reproducible, with waveform precision and linearity to within 1% error for single-pulse experiments. Waveforms acquired in 0.1 s (1000 pulses) with the HPTRF instrument were of sufficient precision to analyze two samples having different lifetimes, resolving minor components with high accuracy with respect to both lifetime and mole fraction. The instrument makes possible a new class of high-throughput time-resolved fluorescence experiments that should be especially powerful for biological applications, including transient kinetics, multidimensional fluorescence, and microplate formats.

[1]  Teresa L. Campos,et al.  Fluorometric Data Processing Strategies Using Nanosecond Waveform Digitizers , 1992 .

[2]  J. R. Taylor,et al.  Investigation of viscosity dependent fluorescence lifetime using a synchronously operated picosecond streak camera , 1980 .

[3]  F. Lytle,et al.  Fast Collection Times for Fluorescence-Decay Measurements , 1991 .

[4]  N. Tamai,et al.  Fluorescence lifetime standards for time and frequency domain fluorescence spectroscopy. , 2007, Analytical chemistry.

[5]  M. Barkley,et al.  Comparison of approaches to the instrumental response function in fluorescence decay measurements. , 1986, Analytical biochemistry.

[6]  A. Ladokhin,et al.  Lifetime fluorescence method for determining membrane topology of proteins. , 2006, Analytical biochemistry.

[7]  Jürgen Wolfrum,et al.  How many photons are necessary for fluorescence-lifetime measurements? , 1992 .

[8]  K. Yoshihara,et al.  Temperature dependence of the nonradiative relaxation process of the lowest excited singlet states of meso-substituted bromoanthracenes , 1983 .

[9]  P. Seybold,et al.  Solvent Dependence of the Fluorescence Lifetimes of Xanthene Dyes , 1999 .

[10]  Kenneth G. Spears,et al.  Hydrogen bond strengths from solvent-dependent lifetimes of Rose Bengal dye , 1978 .

[11]  J M Beechem,et al.  A second generation global analysis program for the recovery of complex inhomogeneous fluorescence decay kinetics. , 1989, Chemistry and physics of lipids.

[12]  David D. Thomas,et al.  Phosphorylation-induced structural changes in smooth muscle myosin regulatory light chain , 2009, Proceedings of the National Academy of Sciences.

[13]  J. K. Thomas,et al.  Single-Pulse Measurements of Fluorescence Lifetimes: The Influence of Solvent on the Isomerization of trans-Stilbene Included in Zeolites , 2001 .

[14]  Jay R. Knutson,et al.  Simultaneous analysis of multiple fluorescence decay curves: A global approach , 1983 .

[15]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[16]  宁北芳,et al.  疟原虫var基因转换速率变化导致抗原变异[英]/Paul H, Robert P, Christodoulou Z, et al//Proc Natl Acad Sci U S A , 2005 .

[17]  M. Daniels,et al.  Lifetime Analysis of Weak Emissions and Time-Resolved Spectral Measurements with a Subnanosecond Dye Laser and Gated Analog Detection , 1992 .

[18]  A. Grinvald The use of standards in the analysis of fluorescence decay data. , 1976, Analytical biochemistry.

[19]  I. V. Negrashov,et al.  Structural dynamics of the myosin relay helix by time-resolved EPR and FRET , 2009, Proceedings of the National Academy of Sciences.

[20]  Ludwig Brand,et al.  Global analysis of fluorescence decay surfaces: excited-state reactions , 1985 .

[21]  J M Beechem,et al.  Global analysis of biochemical and biophysical data. , 1992, Methods in enzymology.