Rehabilitation with calvarial bone grafts and osseointegrated implants after partial maxillary resection: a clinical report.

Osseointegrated implants can be positioned on the nondefect side of a midline maxillary resection if there is sufficient residual bone. Axial loading of the implants is difficult because the axis of rotation for an obturator prosthesis is located along the palatal margin of the defect. Rotation of the prosthesis due to a class I lever will encourage stresses within the implants and the bone surrounding the implants on the nondefect side, and this may be detrimental. Placement of implants within the defect will prevent rotation of the prosthesis and encourage axial loading of the implants.

[1]  N. Markowitz,et al.  Cranial bone graft harvesting: a modified technique. , 1989, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[2]  B Rangert,et al.  Forces and moments on Branemark implants. , 1989, The International journal of oral & maxillofacial implants.

[3]  W. Lawson,et al.  Inverted papilloma: An analysis of 87 cases , 1989, The Laryngoscope.

[4]  K. H. Perzin,et al.  Papillomatosis of nasal cavity and paranasal sinuses (inverted papilloma, squamous papilloma). A clinicopathologic study , 1972, Cancer.