Circuital and Modal Characterization of the Power-Line Network in the PLC Band

With present day measurement techniques, it is very difficult to accurately model the power- line network (PLN), as seen from its power-line terminals, both in terms of impedance and noise. In this paper, a new circuital model (that considers line-ground and neutral-ground signals) and a new modal model (that considers common and the differential mode signals) for characterizing the low voltage PLN are presented. These models, which treat impedance and noise in a unified way, are composed by a three-impedance pi-network and two voltage sources. These models, which are complete and rigorous, are very interesting to desing PLC modems matched to the PLN for maximal power transfer, to compute the energy conversion between common mode and differential mode produced by asymmetries in the PLN, and to know the levels of differential mode noise that will affect a PLC receiver. These models have been experimentally validated.

[1]  Francois D. Martzloff,et al.  Surge and High-Frequency Propagation in Industrial Power Lines , 1986, IEEE Transactions on Industry Applications.

[2]  A. Vukicevic,et al.  Common mode current and radiations mechanisms in PLC networks , 2007, 2007 IEEE International Symposium on Power Line Communications and Its Applications.

[3]  L. M. Millanta,et al.  Power-line impedance and the origin of the low-frequency oscillatory transients , 1990 .

[4]  Roger Vines,et al.  Impedance of the Residential Power-Distribution Circuit , 1985, IEEE Transactions on Electromagnetic Compatibility.

[5]  Erry Gunawan,et al.  A transmission line model for high-frequency power line communication channel , 2002, Proceedings. International Conference on Power System Technology.

[6]  M. Ianoz,et al.  Indoor radiated emission associated with power line communication systems , 2001, 2001 IEEE EMC International Symposium. Symposium Record. International Symposium on Electromagnetic Compatibility (Cat. No.01CH37161).

[7]  Yong Liang Guan,et al.  Characterization of power distribution lines for high-speed data transmission , 2000, PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409).

[8]  N. Theethayi,et al.  The Effects of Load Impedance, Line Length, and Branches in the BPLC—Transmission-Lines Analysis for Medium-Voltage Channel , 2007, IEEE Transactions on Power Delivery.

[9]  P.L. So,et al.  Feasibility Study of Adding a Common-Mode Choke in PLC Modem for EMI Suppression , 2007, IEEE Transactions on Power Delivery.

[10]  Shinji TSUZUKI,et al.  In-door Power-line Impedance Measurement up to High Frequency (10KHz – 70MHz) , 2003 .

[11]  N. Theethayi,et al.  The Effects of Load Impedance, Line Length, and Branches in the BPLC—Transmission-Line Analysis for Indoor Voltage Channel , 2007, IEEE Transactions on Power Delivery.

[12]  W. Dahlke,et al.  Theory of Noisy Fourpoles , 1956, Proceedings of the IRE.

[13]  John A. Malack,et al.  RF Impedance of Power Lines and Line Impedance Stabilization Networks in Conducted Interference Measurements , 1973 .

[14]  P.L. So,et al.  Common-Mode Current Propagation in Power Line Communication Networks Using Multi-Conductor Transmission Line Theory , 2007, 2007 IEEE International Symposium on Power Line Communications and Its Applications.

[15]  E. Gunawan,et al.  Modeling of transfer Characteristics for the broadband power line communication channel , 2004, IEEE Transactions on Power Delivery.

[16]  S. Galli,et al.  A novel approach to the modeling of the indoor power line channel part I: circuit analysis and companion model , 2005, IEEE Transactions on Power Delivery.

[17]  M. Tanaka High frequency noise power spectrum, impedance and transmission loss of power line in Japan on intrabuilding power line communications , 1988 .

[18]  K. Dostert,et al.  Characteristics of Indoor Power Line Channels in the Frequency Range 50 - 500 kHz , 2006, 2006 IEEE International Symposium on Power Line Communications and Its Applications.

[19]  A. Perez,et al.  Characterization of Power-Line Filters and Electronic Equipment for Prediction of Conducted Emissions , 2008, IEEE Transactions on Electromagnetic Compatibility.

[20]  A. J. Kozlowski,et al.  Technique for measurement of powerline impedances in the frequency range from 500 kHz to 500 MHz , 1993 .

[21]  T. Banwell,et al.  A novel approach to the modeling of the indoor power line channel-Part II: transfer function and its properties , 2005, IEEE Transactions on Power Delivery.

[22]  Klaus Dostert,et al.  Fundamental Properties of the Low Voltage Power Distribution Grid Used as a Data Channel , 2000, Eur. Trans. Telecommun..

[23]  E. Gunawan,et al.  Characterization and Modeling of in Building Power Lines for High-Speed Data Transmission , 2002, IEEE Power Engineering Review.

[24]  D. Pozar Microwave Engineering , 1990 .

[25]  E. Gunawan,et al.  Radio-frequency common-mode noise propagation model for power-line cable , 2005, IEEE Transactions on Power Delivery.