A novel support system for patient immobilization and transportation for daily computed tomographic localization of target prior to radiation therapy.

PURPOSE To develop a method for quick and smooth transportation of patients from a computed tomography (CT) table to a linear accelerator (linac) table for confirming tumor center before radiation therapy. MATERIALS AND METHODS We developed a system using a subtable for patient immobilization that is transported via a customized stretcher. The patient lies on the subtable and is immobilized by a vacuum cushion and thermoplastic body cast. The subtable stretcher is used to carry the subtable from the CT table to the linac table. During transportation, the subtable is kept flat and shock to the subtable is carefully avoided. Between August 2001 and September 2002, a total of 9 patients with solitary upper lung tumors (superior to carina) were treated using this system. RESULTS Intrafractional tumor motion along the x (left-right), y (anterior-posterior), and z axis (superior-inferior) ranged from -2 mm to 2 mm, -2 mm to 2 mm, and -5 mm to 3 mm, respectively. The standard deviation of intrafractional tumor motion along the x, y, and z axis ranged from 0.5 mm to 1.5 mm, 0 mm to 1.7 mm, and 0.6 mm to 3.5 mm, respectively. Interfractional setup errors along the x, y, and z axis ranged from -5 mm to 4 mm, -6 mm to 8 mm, and -6 mm to 6 mm, respectively, and we could reduce interfractional setup errors in the majority of treatment sessions. CONCLUSIONS We developed a system that allows patients to be immobilized and transported to verify tumor location on a daily basis. This system is highly useful for reducing setup errors.

[1]  Shinichi Shimizu,et al.  Real-time tumour-tracking radiotherapy , 1999, The Lancet.

[2]  T E Schultheiss,et al.  Daily CT localization for correcting portal errors in the treatment of prostate cancer. , 1998, International journal of radiation oncology, biology, physics.

[3]  J. Wong,et al.  The use of active breathing control (ABC) to reduce margin for breathing motion. , 1999, International journal of radiation oncology, biology, physics.

[4]  James M Balter,et al.  Daily targeting of intrahepatic tumors for radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[5]  M van Herk,et al.  A matrix ionisation chamber imaging device for on-line patient setup verification during radiotherapy. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  M. Uematsu,et al.  A dual computed tomography linear accelerator unit for stereotactic radiation therapy: a new approach without cranially fixated stereotactic frames. , 1996, International journal of radiation oncology, biology, physics.

[7]  M Kono,et al.  Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (FOCAL) unit. , 2000, International journal of radiation oncology, biology, physics.

[8]  Randall K Ten Haken,et al.  Daily prostate targeting using implanted radiopaque markers. , 2001, International journal of radiation oncology, biology, physics.

[9]  T E Schultheiss,et al.  A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer. , 1999, International journal of radiation oncology, biology, physics.