On the interplay effects with proton scanning beams in stage III lung cancer.

PURPOSE To assess the dosimetric impact of interplay between spot-scanning proton beam and respiratory motion in intensity-modulated proton therapy (IMPT) for stage III lung cancer. METHODS Eleven patients were sampled from 112 patients with stage III nonsmall cell lung cancer to well represent the distribution of 112 patients in terms of target size and motion. Clinical target volumes (CTVs) and planning target volumes (PTVs) were defined according to the authors' clinical protocol. Uniform and realistic breathing patterns were considered along with regular- and hypofractionation scenarios. The dose contributed by a spot was fully calculated on the computed tomography (CT) images corresponding to the respiratory phase that the spot is delivered, and then accumulated to the reference phase of the 4DCT to generate the dynamic dose that provides an estimation of what might be delivered under the influence of interplay effect. The dynamic dose distributions at different numbers of fractions were compared with the corresponding 4D composite dose which is the equally weighted average of the doses, respectively, computed on respiratory phases of a 4DCT image set. RESULTS Under regular fractionation, the average and maximum differences in CTV coverage between the 4D composite and dynamic doses after delivery of all 35 fractions were no more than 0.2% and 0.9%, respectively. The maximum differences between the two dose distributions for the maximum dose to the spinal cord, heart V40, esophagus V55, and lung V20 were 1.2 Gy, 0.1%, 0.8%, and 0.4%, respectively. Although relatively large differences in single fraction, correlated with small CTVs relative to motions, were observed, the authors' biological response calculations suggested that this interfractional dose variation may have limited biological impact. Assuming a hypofractionation scenario, the differences between the 4D composite and dynamic doses were well confined even for single fraction. CONCLUSIONS Despite the presence of interplay effect, the delivered dose may be reliably estimated using the 4D composite dose. In general the interplay effect may not be a primary concern with IMPT for lung cancers for the authors' institution. The described interplay analysis tool may be used to provide additional confidence in treatment delivery.

[1]  Xiaodong Zhang,et al.  Beyond Gaussians: a study of single-spot modeling for scanning proton dose calculation , 2012, Physics in medicine and biology.

[2]  Xiaoning Pan,et al.  A methodology for automatic intensity-modulated radiation treatment planning for lung cancer , 2011, Physics in medicine and biology.

[3]  Zuofeng Li,et al.  Proton therapy for lung cancer , 2012, Thoracic cancer.

[4]  TUMOR AND NORMAL TISSUE RESPONSES TO XA 9642842 FRACTIONATED NON-UNIFORM DOSE DELIVERY , 2005 .

[5]  Joe Y. Chang,et al.  Validation of an accelerated ‘demons’ algorithm for deformable image registration in radiation therapy , 2005, Physics in medicine and biology.

[6]  E Heath,et al.  Dosimetric consequences of tumour motion due to respiration for a scanned proton beam , 2011, Physics in medicine and biology.

[7]  Radhe Mohan,et al.  Robust optimization of intensity modulated proton therapy. , 2012, Medical physics.

[8]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[9]  Uwe Titt,et al.  Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston. , 2009, Medical physics.

[10]  Christoph Bert,et al.  Quantification of interplay effects of scanned particle beams and moving targets , 2008, Physics in medicine and biology.

[11]  Eike Rietzel,et al.  Four-dimensional proton treatment planning for lung tumors. , 2006, International journal of radiation oncology, biology, physics.

[12]  Joe Y. Chang,et al.  4D Proton treatment planning strategy for mobile lung tumors. , 2007, International journal of radiation oncology, biology, physics.

[13]  Wei Liu,et al.  Dynamically accumulated dose and 4D accumulated dose for moving tumors. , 2012, Medical physics.

[14]  Shinichi Shimizu,et al.  Intrafractional tumor motion: lung and liver. , 2004, Seminars in radiation oncology.

[15]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[16]  A. Lomax,et al.  Intensity modulation methods for proton radiotherapy. , 1999, Physics in medicine and biology.

[17]  Steve B. Jiang,et al.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. , 2002, Physics in medicine and biology.

[18]  A. Berman,et al.  An in-silico comparison of proton beam and IMRT for postoperative radiotherapy in completely resected stage IIIA non-small cell lung cancer , 2013, Radiation oncology.

[19]  J. Lambert,et al.  Intrafractional motion during proton beam scanning , 2005, Physics in medicine and biology.

[20]  Evaluation and comparison of New 4DCT based strategies for proton treatment planning for lung tumors , 2013, Radiation oncology.

[21]  Radhe Mohan,et al.  An efficient dose calculation strategy for intensity modulated proton therapy. , 2011, Physics in medicine and biology.

[22]  James Shackleford,et al.  Motion interplay as a function of patient parameters and spot size in spot scanning proton therapy for lung cancer. , 2013, International journal of radiation oncology, biology, physics.

[23]  Radhe Mohan,et al.  Intensity-modulated proton therapy reduces the dose to normal tissue compared with intensity-modulated radiation therapy or passive scattering proton therapy and enables individualized radical radiotherapy for extensive stage IIIB non-small-cell lung cancer: a virtual clinical study. , 2010, International journal of radiation oncology, biology, physics.

[24]  R. Pötter,et al.  Can protons improve SBRT for lung lesions? Dosimetric considerations. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  George Starkschall,et al.  Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer. , 2007, International journal of radiation oncology, biology, physics.