Biomechanics effect of two implant system with different bone height under axial and non–axial loading conditions

The objective of this current in silico study was to evaluate the influence of axial and non-axial loads on unitary implant-supported implants, with external hexagon or Morse-taper connection in two different bone level, using finite element analysis. Two implant models with the same length (13 x 3.75 mm) were analyzed according to the prosthetic connection (external hexagon or morse Taper) and bone height (bone level or 5 mm of bone loss). Both implant systems received screw-retained metallic crowns in chromium-cobalt. The peri-implant tissue was simulated as an isotropic material (polyurethane resin). The polyurethane block has been fixed and a load of 300 N was applied on the occlusal surface in two different directions (Axial or Non-axial) for each implant model and bone condition. The results were analyzed in terms of von-Mises stress and bone microstrain. The materials were considered isotropic, homogeneous, linear and elastic. The results showed that there is no difference regarding the prosthetic connection for the generated stress and strain under the same load incidence. However, bone loss and non-axial loadings increased the stress and strain magnitude regardless the prosthetic connections. In conclusion, the load incidence is more prone to modify the implant stress and bone microstrain than the prosthethic connection. In addition, the higher the bone loss the higher the stress and strain magnitude generated, regardless the loading condition.

[1]  A. Borges,et al.  The effect of different bone level and prosthetic connection on the biomechanical response of unitary implants: Strain gauge and finite element analyses , 2021, International Journal of Advanced Engineering Research and Science.

[2]  D. Kemmoku,et al.  Effect of bone quality and bone loss level around internal and external connection implants: A finite element analysis study. , 2020, The Journal of prosthetic dentistry.

[3]  João Paulo Mendes Tribst,et al.  Silica-Nylon Reinforcement Effect on the Fracture Load and Stress Distribution of a Resin-Bonded Partial Dental Prosthesis. , 2020, The International journal of periodontics & restorative dentistry.

[4]  João Paulo Mendes Tribst,et al.  Evaluation of Zirconia and Cobalt-Chrome for Custom-Milled Framework Design for an Implant-Supported Full-Arch Fixed Dental Prosthesis: A Finite Element Analysis , 2020 .

[5]  João Paulo Mendes Tribst,et al.  Effect of Framework Type on the Biomechanical Behavior of Provisional Crowns: Strain Gauge and Finite Element Analyses. , 2020, The International journal of periodontics & restorative dentistry.

[6]  Nurullah Turker,et al.  Retrospective evaluation of marginal bone loss around implants in a mandibular locator-retained denture using panoramic radiographic images and finite element analysis: A pilot study. , 2019, Clinical implant dentistry and related research.

[7]  M. Bottino,et al.  Influence of implant connection on the stress distribution in restorations performed with hybrid abutments , 2019 .

[8]  Estevam Barbosa de Las Casas,et al.  Stress distribution in dental roots restored with different post and core materials , 2019, Journal of International Oral Health.

[9]  R. Nishioka,et al.  Application of Bio-Oss in tissue regenerative treatment prior to implant installation: literature review , 2019, Brazilian Dental Science.

[10]  João Paulo Mendes Tribst,et al.  Monolithic zirconia crown does not increase the peri-implant strain under axial load , 2019, Journal of International Oral Health.

[11]  João Paulo Mendes Tribst,et al.  Effect of implant number and height on the biomechanics of full arch prosthesis , 2018, Brazilian Journal of Oral Sciences.

[12]  João Paulo Mendes Tribst,et al.  Biomechanical effect of inclined implants in fixed prosthesis: strain and stress analysis , 2018, Revista de Odontologia da UNESP.

[13]  João Paulo Mendes Tribst,et al.  Influence of different restorative materials on the stress distribution in dental implants , 2018, Journal of clinical and experimental dentistry.

[14]  João Paulo Mendes Tribst,et al.  Validation of a Simplified Implant-Retained Cantilever Fixed Prosthesis , 2018, Implant dentistry.

[15]  João Paulo Mendes Tribst,et al.  The importance of correct implants positioning and masticatory load direction on a fixed prosthesis , 2018, Journal of clinical and experimental dentistry.

[16]  João Paulo Mendes Tribst,et al.  Influence of implantoplasty on stress distribution of exposed implants at different bone insertion levels. , 2017, Brazilian oral research.

[17]  Igor Linetskiy,et al.  Impact of annual bone loss and different bone quality on dental implant success - A finite element study , 2017, Comput. Biol. Medicine.

[18]  João Paulo Mendes Tribst,et al.  Stress and strain distributions on short implants with two different prosthetic connections – an in vitro and in silico analysis , 2017 .

[19]  João Paulo Mendes Tribst,et al.  Influence of angulation and vertical misfit in the evaluation of micro-deformations around implants , 2017 .

[20]  João Paulo Mendes Tribst,et al.  Microscopic evaluation of implant platform adaptation with UCLA-type abutments: in vitro study , 2017 .

[21]  V. Rodrigues,et al.  Comparative Microstrain Study of Internal Hexagon and Plateau Design of Short Implants Under Vertical Loading , 2016, Implant dentistry.

[22]  S. M. Rode,et al.  Load-application devices: a comparative strain gauge analysis. , 2015, Brazilian dental journal.

[23]  L. D. de Vasconcellos,et al.  Axial loads on implant-supported partial fixed prostheses for external and internal hex connections and machined and plastic copings: strain gauge analysis. , 2015, The Journal of oral implantology.

[24]  L. Valandro,et al.  Fatigue surviving, fracture resistance, shear stress and finite element analysis of glass fiber posts with different diameters. , 2015, Journal of the mechanical behavior of biomedical materials.

[25]  W. Müller,et al.  Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone. , 2015, Journal of biomechanics.

[26]  L. D. de Vasconcellos,et al.  Microstrain Around Dental Implants Supporting Fixed Partial Prostheses Under Axial and Non–Axial Loading Conditions, In Vitro Strain Gauge Analysis , 2013, The Journal of craniofacial surgery.

[27]  R. Nishioka,et al.  Strain Gauge analysis of non-axial loads in three-element implant-supported prostheses , 2013 .

[28]  R. Nishioka,et al.  Strain Gauge: study of strain distributions around three Morse taper prosthetic connections with offset positioning in machined and plastic copings under vertical load , 2012 .

[29]  J. Shibli,et al.  Influence of titanium surface treatments on formation of the blood clot extension. , 2011, The Journal of oral implantology.

[30]  L. D. de Vasconcellos,et al.  Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis , 2011, Journal of applied oral science : revista FOB.

[31]  R. Nishioka,et al.  Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration , 2011, Implant dentistry.

[32]  J. H. Rubo,et al.  Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests , 2011, Journal of applied oral science : revista FOB.

[33]  I. Balducci,et al.  Machined and plastic copings in three-element prostheses with different types of implantabutment joints: a strain gauge comparative analysis , 2010, Journal of applied oral science : revista FOB.

[34]  F. A. Souza,et al.  Bone spreader technique: a preliminary 3-year study. , 2009, The Journal of oral implantology.

[35]  R. Nishioka,et al.  External Hexagon and Internal Hexagon in Straight and Offset Implant Placement: Strain Gauge Analysis , 2009, Implant dentistry.

[36]  Fehmi Erzincanlı,et al.  Static, dynamic and fatigue behaviors of dental implant using finite element method , 2006, Adv. Eng. Softw..

[37]  R. Mericske-Stern,et al.  Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants. , 1996, The International journal of oral & maxillofacial implants.

[38]  H. Frost,et al.  Wolff's Law and bone's structural adaptations to mechanical usage: an overview for clinicians. , 2009, The Angle orthodontist.

[39]  G Zarb,et al.  The long-term efficacy of currently used dental implants: a review and proposed criteria of success. , 1986, The International journal of oral & maxillofacial implants.