Monitoring lung resistivity changes in congestive heart failure patients using the bioimpedance technique.

The feasibility of a novel, dedicated system for monitoring lung resistivity in congestive heart failure patients, implementing a hybrid approach of the bioimpedance technique, was assessed in this preliminary study. Thirty-three healthy volunteers and 34 congestive heart failure patients were measured with the PulmoTrace system (CardioInspect, Tel Aviv University, Tel Aviv, Israel) during tidal respiration, and the ability to monitor the respective lung resistivity values was assessed. Mean left and right lung resistivity values of 1205+/-163 and 1200+/-165 ohm.cm for the control group and 888+/-193 and 943+/-187 ohm.cm for the congestive heart failure group were found, indicating a significant (p<2.10(-7)) difference between the two groups. The results of long-term monitoring of two patients during medical treatment are also shown. This hybrid approach system is believed to improve diagnostic capabilities and help physicians to better adjust medication dosage on a frequent basis.

[1]  A. Guyton,et al.  Textbook of Medical Physiology , 1961 .

[2]  A. Morice,et al.  Clinical applications of electrical impedance tomography in the monitoring of changes in intrathoracic fluid volumes. , 1994, Physiological measurement.

[3]  B Eiseman,et al.  Transthoracic electrical impedance for the early detection of pulmonary edema. , 1969, Surgery.

[4]  J. Newell,et al.  Assessment of acute pulmonary edema in dogs by electrical impedance imaging , 1996, IEEE Transactions on Biomedical Engineering.

[5]  C. Saunders The use of transthoracic electrical bioimpedance in assessing thoracic fluid status in emergency department patients. , 1988, The American journal of emergency medicine.

[6]  Willis J. Tompkins,et al.  Comparing Reconstruction Algorithms for Electrical Impedance Tomography , 1987, IEEE Transactions on Biomedical Engineering.

[7]  P C Goodman,et al.  Evaluation of Transthoracic Electrical Impedance in the Diagnosis of Pulmonary Edema , 1979, Circulation.

[8]  B H Brown,et al.  Monitoring patients with left ventricular failure by electrical impedance tomography , 1999, European journal of heart failure.

[9]  F. Spinale,et al.  Bioimpedance: a novel method for the determination of extravascular lung water. , 1990, The Journal of surgical research.

[10]  Robert P Patterson,et al.  Improved lung edema monitoring with coronary vein pacing leads: a simulation study. , 2004, Physiological measurement.

[11]  G Charach,et al.  Transthoracic monitoring of the impedance of the right lung in patients with cardiogenic pulmonary edema , 2001, Critical care medicine.

[12]  T. J. Noble,et al.  Diuretic induced change in lung water assessed by electrical impedance tomography. , 2000, Physiological measurement.

[13]  Sujoy K. Guha,et al.  Quantitative electrical-impedance plethysmography for pulmonary oedema , 1977, Medical and Biological Engineering and Computing.

[14]  B. Greenberg,et al.  Reproducibility of impedance cardiography hemodynamic measures in clinically stable heart failure patients. , 2000, Congestive heart failure.

[15]  D C Barber,et al.  Applied potential tomography: a new technique for monitoring pulmonary function. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[16]  B. Brown,et al.  Applied potential tomography: possible clinical applications. , 1985, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.