Comparison of photoacoustic imaging systems using continuous-wave lasers with a chirped intensity modulation frequency to pulsed lasers

We compare imaging systems using continuous-wave (CW) lasers with a chirped intensity modulation frequency to pulsed lasers. We show that the resolution is the same in both cases. We also compare the signal-to-noise ratio (SNR) of the two systems assuming the fluence is set by the American National Standards Institute (ANSI) limits. Although the SNR depends on several parameters, we find that it is about 20 dB to 30 dB larger for pulsed lasers for reasonable values of the parameters. However, CW diode lasers have the advantage of being compact and relatively inexpensive, which may outweigh the slightly lower SNR in many applications.

[1]  M. J. Rycroft,et al.  Radar signals: An introduction to theory and application , 1995 .

[2]  Harrison H. Barrett,et al.  Foundations of Image Science , 2003, J. Electronic Imaging.

[3]  Andreas Mandelis,et al.  Development of a laser photothermoacoustic frequency-swept system for subsurface imaging: theory and experiment. , 2004, The Journal of the Acoustical Society of America.

[4]  Andreas Mandelis,et al.  Photothermoacoustic imaging of biological tissues: maximum depth characterization comparison of time and frequency-domain measurements. , 2009, Journal of biomedical optics.

[5]  Andreas Mandelis,et al.  Frequency-domain photothermoacoustics: Alternative imaging modality of biological tissues , 2009 .

[6]  Lihong V. Wang,et al.  Tutorial on Photoacoustic Microscopy and Computed Tomography , 2008, IEEE Journal of Selected Topics in Quantum Electronics.

[7]  Andreas Mandelis,et al.  Fourier-domain methodology for depth-selective photothermoacoustic imaging of tissue chromophores , 2008 .

[8]  Andreas Mandelis,et al.  Fourier-domain biophotoacoustic subsurface depth selective amplitude and phase imaging of turbid phantoms and biological tissue. , 2006, Journal of biomedical optics.

[9]  Patrick J. La Rivière,et al.  Comparison of intensity-modulated continuous-wave lasers with a chirped modulation frequency to pulsed lasers for photoacoustic imaging applications , 2010, Biomedical optics express.

[10]  Laser photothermoacoustic heterodyned lock-in depth profilometry in turbid tissue phantoms. , 2005, Physical review. E, Statistical, nonlinear, and soft matter physics.

[11]  Lihong V Wang,et al.  Photoacoustic tomography and sensing in biomedicine , 2009, Physics in medicine and biology.