HTS techniques for patch clamp-based ion channel screening – advances and economy

Introduction: Ten years ago, the first publication appeared showing patch clamp recordings performed on a planar glass chip instead of using a conventional patch clamp pipette. “Going planar” proved to revolutionize ion channel drug screening as we know it, by allowing high quality measurements of ion channels and their effectors at a higher throughput and at the same time de-skilling the highly laborious technique. Over the years, platforms evolved in response to user requirements regarding experimental features, data handling plus storage, and suitable target diversity. Areas covered: This article gives a snapshot image of patch clamp-based ion channel screening with focus on platforms developed to meet requirements of high-throughput screening environments. The commercially available platforms are described, along with their benefits and drawbacks in ion channel drug screening. Expert opinion: Automated patch clamp (APC) platforms allow faster investigation of a larger number of ion channel active compounds or cell clones than previously possible. Since patch clamp is the only method allowing direct, real-time measurements of ion channel activity, APC holds the promise of picking up high quality leads, where they otherwise would have been overseen using indirect methods. In addition, drug candidate safety profiling can be performed earlier in the drug discovery process, avoiding late-phase compound withdrawal due to safety liability issues, which is highly costly and inefficient.

[1]  R. Peri,et al.  High-throughput electrophysiology: an emerging paradigm for ion-channel screening and physiology , 2008, Nature Reviews Drug Discovery.

[2]  John Comley,et al.  8 years of surveying ion channel screening - has anything changed? , 2011 .

[3]  J. Ruppersberg Ion Channels in Excitable Membranes , 1996 .

[4]  Henry J. Duff,et al.  Exaggerated block of hERG (KCNH2) and prolongation of action potential duration by erythromycin at temperatures between 37°C and 42°C , 2005 .

[5]  Michael George,et al.  Ion channel screening - automated patch clamp on the rise. , 2008, Drug discovery today. Technologies.

[6]  Mark J. Rose,et al.  Pharmacological blockade of the vanilloid receptor TRPV1 elicits marked hyperthermia in humans , 2008, PAIN.

[7]  Renza Roncarati,et al.  Screening technologies for ion channel drug discovery. , 2010, Future medicinal chemistry.

[8]  Henry J Duff,et al.  Exaggerated block of hERG (KCNH2) and prolongation of action potential duration by erythromycin at temperatures between 37 degrees C and 42 degrees C. , 2005, Heart rhythm.

[9]  B. Sakmann,et al.  Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches , 1981, Pflügers Archiv.

[10]  John P. Overington,et al.  How many drug targets are there? , 2006, Nature Reviews Drug Discovery.

[11]  P. Negulescu,et al.  Cell-based assays and instrumentation for screening ion-channel targets. , 1999, Drug discovery today.

[12]  Clemens Möller,et al.  Automated Electrophysiology Makes the Pace for Cardiac Ion Channel Safety Screening , 2011, Front. Pharmacol..

[13]  Jeffrey J Clare,et al.  Targeting ion channels for drug discovery. , 2010, Discovery medicine.

[14]  Niels Fertig,et al.  Planar Patch Clamping , 2007 .

[15]  Chris Mathes,et al.  QPatch: the past, present and future of automated patch clamp , 2006, Expert opinion on therapeutic targets.

[16]  David L Downie,et al.  Novel 384-Well Population Patch Clamp Electrophysiology Assays for Ca2+-Activated K+ Channels , 2007, Journal of biomolecular screening.

[17]  J. Ruskin,et al.  Drug‐Induced Torsades de Pointes and Implications for Drug Development , 2004, Journal of cardiovascular electrophysiology.

[18]  D. Rothwarf,et al.  A benchmark study with sealchip planar patch-clamp technology. , 2003, Assay and drug development technologies.

[19]  Jürgen Rühe,et al.  Nanopore-based single-molecule mass spectrometry on a lipid membrane microarray. , 2011, ACS nano.

[20]  Robert H Blick,et al.  Whole cell patch clamp recording performed on a planar glass chip. , 2002, Biophysical journal.

[21]  Ralf Kettenhofen,et al.  State-of-the-Art Automated Patch Clamp Devices: Heat Activation, Action Potentials, and High Throughput in Ion Channel Screening , 2011, Front. Pharmacol..

[22]  Alan Finkel,et al.  Population Patch Clamp Improves Data Consistency and Success Rates in the Measurement of Ionic Currents , 2006, Journal of biomolecular screening.

[23]  Cristian Ionescu-Zanetti,et al.  IonFlux: a microfluidic patch clamp system evaluated with human Ether-à-go-go related gene channel physiology and pharmacology. , 2011, Assay and drug development technologies.

[24]  A. Brown,et al.  Variability in the measurement of hERG potassium channel inhibition: effects of temperature and stimulus pattern. , 2004, Journal of pharmacological and toxicological methods.

[25]  Cecilia Farre,et al.  Renaissance of ion channel research and drug discovery by patch clamp automation. , 2010, Future medicinal chemistry.

[26]  Ralf Kettenhofen,et al.  Automated Patch Clamp on mESC-Derived Cardiomyocytes for Cardiotoxicity Prediction , 2011, Journal of biomolecular screening.

[27]  David E. Clapham,et al.  TRP channels as cellular sensors , 2003, Nature.

[28]  Mark L Dallas,et al.  Robotic multiwell planar patch-clamp for native and primary mammalian cells , 2009, Nature Protocols.

[29]  A Brüggemann,et al.  High quality ion channel analysis on a chip with the NPC technology. , 2003, Assay and drug development technologies.