Aseptic simulation test for cytotoxic drug production in isolators.

PURPOSE The results of a media-fill test (MFT) study to validate processes for cytotoxic drug preparation inside and outside aseptic compounding isolators are presented. METHODS Using an MFT protocol adapted to institution-specific production conditions, the pharmacy team at a hospital in France performed a series of tests to verify the efficacy of decontamination and sterile compounding procedures, as required by French compendial standards, while assessing the performance of its team of 12 isolator operators; all operators were tested on three occasions, producing 10 MFT samples per test for a total of 30 samples per operator. The team also tested alternative compounding systems (i.e., two closed-system transfer devices and a classic spike system) for use during power outages or other emergencies precluding drug preparation within isolators. MFTs were performed using a standard tryptone soy broth-based test kit under worst-case conditions. RESULTS The hospital's facilities for cytotoxic drug preparation were found to be in conformance with applicable sterility standards. Bacterial growth was not detected in any of the MFT samples produced by isolator operators during the study (total n = 360). In one instance, an MFT sample prepared using a closed-system transfer device was found to be contaminated due to improper cleaning of the medication vial, highlighting the importance of strict adherence to proper decontamination procedures. CONCLUSION A hospital's practices for preparation of sterile products according to applicable good manufacturing guidelines, as well as emergency procedures for cytotoxic drug preparation outside isolators, were validated by the results of an MFT study.

[1]  D. Brossard,et al.  Aseptic simulation test challenged with microorganisms for validation of pharmacy operators. , 2012, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[2]  P. Bonnabry,et al.  Multiple-test assessment of devices to protect healthcare workers when administering cytotoxic drugs to patients , 2012, Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners.

[3]  S. Soefje,et al.  Evaluation of surface contamination with cyclophosphamide following simulated hazardous drug preparation activities using two closed-system products , 2011, Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners.

[4]  P. Sessink,et al.  Reduction in surface contamination with antineoplastic drugs in 22 hospital pharmacies in the US following implementation of a closed-system drug transfer device , 2011, Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners.

[5]  H. Nelis,et al.  Microbiological challenge of four protective devices for the reconstitution of cytotoxic agents , 2008, Letters in applied microbiology.

[6]  K. McCall,et al.  Parenterals laboratory course to reduce microbial contamination rates in media fill tests performed by pharmacy students. , 2008, American journal of pharmaceutical education.

[7]  M. Sanborn,et al.  I.V. admixture contamination rates: traditional practice site versus a class 1000 cleanroom. , 2005, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[8]  P. Prognon,et al.  Evaluation of peracetic acid permeation during flash sterilization through pharmaceutical plastic polymers used in cytotoxic reconstitution units. , 2005, PDA journal of pharmaceutical science and technology.

[9]  R. Anderson,et al.  Using a medium-fill simulation to evaluate the microbial contamination rate for USP medium-risk-level compounding. , 2005, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[10]  Ryan A. Forrey,et al.  Utility of the PhaSeal Closed System Drug Transfer Device , 2011 .