Statistical inference for the area under the receiver operating characteristic curve in the presence of random measurement error.

The area under the receiver operating characteristic curve is the most commonly used measure of the ability of a biomarker to distinguish between two populations. Some markers are subject to substantial measurement error. Under normality assumptions, the authors develop a confidence interval procedure for the area under the receiver operating characteristic curve that adjusts for measurement error. This procedure assumes the availability of data from a reliability study of the biomarker. A simulation study was used to check the validity of the proposed confidence interval. Furthermore, it was shown that not adjusting for measurement error could result in a serious understatement of the effectiveness of the biomarker.

[1]  H. Garewal,et al.  Antioxidants and the prevention of coronary heart disease. , 1995, Archives of internal medicine.

[2]  M. Coffin,et al.  Receiver operating characteristic studies and measurement errors. , 1997, Biometrics.

[3]  A. Dyer,et al.  Statistical methods to assess and minimize the role of intra-individual variability in obscuring the relationship between dietary lipids and serum cholesterol. , 1978, Journal of chronic diseases.

[4]  S. R. Searle Linear Models , 1971 .

[5]  S. K. Lo,et al.  Reliability and Validity , 2020, International Encyclopedia of Human Geography.

[6]  B Reiser,et al.  Measuring the effectiveness of diagnostic markers in the presence of measurement error through the use of ROC curves. , 2000, Statistics in medicine.

[7]  Irwin Guttman,et al.  Statistical inference for Pr(Y < X): The normal case , 1986 .

[8]  D. Bamber The area above the ordinal dominance graph and the area below the receiver operating characteristic graph , 1975 .

[9]  Elisa T. Lee,et al.  Use of relative operating characteristic analysis in epidemiology. A method for dealing with subjective judgement. , 1981, American journal of epidemiology.

[10]  D Faraggi,et al.  The effect of random measurement error on receiver operating characteristic (ROC) curves. , 2000, Statistics in medicine.

[11]  Graham Dunn,et al.  Design and Analysis of Reliability Studies: The Statistical Evaluation of Measurement Errors , 1989 .

[12]  N. Draper,et al.  Applied Regression Analysis , 1966 .

[13]  A Parametric Approach to Measurement Errors in Receiver Operating Characteristic Studies , 1996 .

[14]  J. Hanley,et al.  The meaning and use of the area under a receiver operating characteristic (ROC) curve. , 1982, Radiology.

[15]  Rupert G. Miller,et al.  Survival Analysis , 2022, The SAGE Encyclopedia of Research Design.