A perfusion procedure for imaging of the mouse cerebral vasculature by X-ray micro-CT

BACKGROUND Micro-CT is a novel X-ray imaging modality which can provide 3D high resolution images of the vascular network filled with contrast agent. The cerebrovascular system is a complex anatomical structure that can be imaged with contrast enhanced micro-CT. However, the morphology of the cerebrovasculature and many circulatory anastomosis in the brain result in high variations in the extent of contrast agent filling in the blood vessels and as a result, the vasculature of different subjects appear differently in the acquired images. Specifically, the posterior circulation is not consistently perfused with the contrast agent in many brain specimens and thus, many major vessels that perfuse blood to the midbrain and hindbrain are not visible in the micro-CT images acquired from these samples. NEW METHOD In this paper, we present a modified surgical procedure of cerebral vasculature perfusion through the left ventricle with Microfil contrast agent, in order to achieve a more uniform perfusion of blood vessels throughout the brain and as a result, more consistent images of the cerebrovasculature. Our method consists of filling the posterior cerebral circulation with contrast agent, followed by the perfusion of the whole cerebrovasculature. RESULTS Our histological results show that over 90% of the vessels in the entire brain, including the cerebellum, were filled with contrast agent. COMPARISON WITH EXISTING METHOD Our results show that the new technique of sample perfusion decreases the variability of the posterior circulation in the cerebellum in micro-CT images by 6.9%. CONCLUSIONS This new technique of sample preparation improves the quality of cerebrovascular images.

[1]  Stanley N. Schwartz,et al.  Physiology and Biophysics of the Circulation. , 1965 .

[2]  Elias A. Rivera,et al.  A comparison of experimental aneurysm occlusion determination by angiography, scanning electron microscopy, MICROFIL perfusion, and histology. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[3]  M. Wheeler,et al.  Episodic coronary artery vasospasm and hypertension develop in the absence of Sur2 K(ATP) channels. , 2002, The Journal of clinical investigation.

[4]  N. Beckmann,et al.  High resolution magnetic resonance angiography non‐invasively reveals mouse strain differences in the cerebrovascular anatomy in vivo , 2000, Magnetic resonance in medicine.

[5]  J. Sled,et al.  3D visualisation and quantification by microcomputed tomography of late gestational changes in the arterial and venous feto-placental vasculature of the mouse. , 2007, Placenta.

[6]  F. Faraci,et al.  Selective cerebral vascular dysfunction in Mn-SOD-deficient mice. , 2006, Journal of applied physiology.

[7]  T. Sandor,et al.  Resting host and tumor perfusion as determinants of tumor vascular responses to norepinephrine. , 1979, Cancer research.

[8]  J. Eckenhoff,et al.  Physiology and Biophysics of the Circulation , 1965 .

[9]  John G. Sled,et al.  Measurement of cerebral blood volume in mouse brain regions using micro-computed tomography , 2009, NeuroImage.

[10]  P. Scheel,et al.  Color duplex measurement of cerebral blood flow volume in healthy adults. , 2000, Stroke.

[11]  R M Henkelman,et al.  Comparative structural and hemodynamic analysis of vascular trees. , 2010, American journal of physiology. Heart and circulatory physiology.

[12]  Jacqui Detmar,et al.  Vessel tortuousity and reduced vascularization in the fetoplacental arterial tree after maternal exposure to polycyclic aromatic hydrocarbons. , 2011, American journal of physiology. Heart and circulatory physiology.

[13]  Nicolas P Smith,et al.  Structural morphology of renal vasculature. , 2006, American journal of physiology. Heart and circulatory physiology.

[14]  Thomas Krucker,et al.  New polyurethane‐based material for vascular corrosion casting with improved physical and imaging characteristics , 2006, Microscopy research and technique.

[15]  T. Rülicke,et al.  Optimization of intraperitoneal injection anesthesia in mice: drugs, dosages, adverse effects, and anesthesia depth. , 2001, Comparative medicine.

[16]  W. Young,et al.  Cerebrovascular Casting of the Adult Mouse for 3D Imaging and Morphological Analysis , 2011, Journal of visualized experiments : JoVE.

[17]  R M Henkelman,et al.  Comparing microsphere deposition and flow modeling in 3D vascular trees. , 2006, American journal of physiology. Heart and circulatory physiology.

[18]  R Mark Henkelman,et al.  MicroCT scanner performance and considerations for vascular specimen imaging. , 2004, Medical physics.

[19]  M. Daneyemez Microangiographic changes following cerebral contusion in rats , 1999, Neuroscience.

[20]  R. Mark Henkelman,et al.  High resolution three-dimensional brain atlas using an average magnetic resonance image of 40 adult C57Bl/6J mice , 2008, NeuroImage.

[21]  S Cortell,et al.  Silicone rubber for renal tubular injection. , 1969, Journal of applied physiology.

[22]  M. Jones,et al.  New Techniques for 3 D , High-Resolution , Whole Brain Mapping of Murine Vasculature , 2007 .

[23]  Erik L Ritman,et al.  The use of microcomputed tomography to study microvasculature in small rodents. , 2002, American journal of physiology. Regulatory, integrative and comparative physiology.

[24]  Feng Gao,et al.  Optimization of MicroCT Imaging and Blood Vessel Diameter Quantitation of Preclinical Specimen Vasculature with Radiopaque Polymer Injection Medium , 2011, PloS one.

[25]  S M Jorgensen,et al.  Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with X-ray micro-CT. , 1998, The American journal of physiology.

[26]  R. Pearlstein,et al.  A comparison of strain-related susceptibility in two murine recovery models of global cerebral ischemia , 2000, Brain Research.

[27]  Maria Siebes,et al.  3D Imaging of vascular networks for biophysical modeling of perfusion distribution within the heart. , 2013, Journal of biomechanics.

[28]  D. Holdsworth,et al.  Micro-CT in small animal and specimen imaging , 2002 .

[29]  John K-J. Li,et al.  Dynamics of the vascular system , 2004 .

[30]  Keiji Umetani,et al.  In Vivo X-Ray Angiography in the Mouse Brain Using Synchrotron Radiation , 2006, Stroke.

[31]  Philipp Schneider,et al.  Hierarchical microimaging for multiscale analysis of large vascular networks , 2006, NeuroImage.

[32]  Charles Watson,et al.  The Mouse Nervous System. , 2012 .