In vitro exposure apparatus for ELF magnetic fields

For in vitro studies on the effect of extremely low frequency (ELF) magnetic field exposures in different laboratories, a programmable, high precision exposure system enabling blinded exposures has been developed and fully characterized. It is based on two shielded 4 coil systems that fit inside a commercial incubator. The volume of uniform B field exposure with 1% field tolerance is 50% larger compared to a Merrit 4 coil system with the same coil volume. The uncertainties for the applied magnetic fields have been specified to be less than 4%. The computer controlled apparatus allows signal waveforms that are composed of several harmonics, blind protocols, monitoring of exposure and environmental conditions and the application of B fields up to 3.6 mT root-mean-square amplitude. Sources of artifacts have been characterized: sham isolation >43 dB, parasitic incident E fields <1 V/m, no recognizable temperature differences in the media for exposure or sham state, and vibrations of the mechanically decoupled dish holder <0.1 m/s(2) (= 0.01 g), which is only twice the sham acceleration background level produced by the incubator and fan vibrations.

[1]  M. A. Stuchly,et al.  Computer controlled system for producing uniform magnetic fields and its application in biomedical research , 1996 .

[2]  M Misakian,et al.  Biological, physical, and electrical parameters for in vitro studies with ELF magnetic and electric fields: a primer. , 1993, Bioelectromagnetics.

[3]  P A Valberg,et al.  Designing EMF experiments: what is required to characterize "exposure"? , 1995, Bioelectromagnetics.

[4]  J. Kirschvink,et al.  Uniform magnetic fields and double-wrapped coil systems: improved techniques for the design of bioelectromagnetic experiments. , 1992, Bioelectromagnetics.

[5]  N Kuster,et al.  Recommended minimal requirements and development guidelines for exposure setups of bio-experiments addressing the health risk concern of wireless communications. , 2000, Bioelectromagnetics.

[6]  T Shigemitsu,et al.  Low stray ELF magnetic field exposure system for in vitro study. , 2000, Bioelectromagnetics.

[7]  G Gottardi,et al.  A four coil exposure system (tetracoil) producing a highly uniform magnetic field , 2003, Bioelectromagnetics.

[8]  C C Davis,et al.  Food and Drug Administration low-level extremely-low-frequency magnetic field exposure facility. , 1999, Bioelectromagnetics.

[9]  B F Sisken,et al.  Design and characterization of a system for exposure of cultured cells to extremely low frequency electric and magnetic fields over a wide range of field strengths. , 1993, Bioelectromagnetics.

[10]  G. Stroink,et al.  Uniform magnetic field produced by three, four, and five square coils , 1983 .

[11]  An integrated ELF magnetic-field generator and incubator for long-term in vitro studies. , 1992, Bioelectromagnetics.

[12]  M A Stuchly,et al.  Design and fabrication of well confined uniform magnetic field exposure systems. , 1994, Bioelectromagnetics.