An automatic fall detection framework using data fusion of Doppler radar and motion sensor network

This paper describes the ongoing work of detecting falls in independent living senior apartments. We have developed a fall detection system with Doppler radar sensor and implemented ceiling radar in real senior apartments. However, the detection accuracy on real world data is affected by false alarms inherent in the real living environment, such as motions from visitors. To solve this issue, this paper proposes an improved framework by fusing the Doppler radar sensor result with a motion sensor network. As a result, performance is significantly improved after the data fusion by discarding the false alarms generated by visitors. The improvement of this new method is tested on one week of continuous data from an actual elderly person who frequently falls while living in her senior home.

[1]  Andrew Sixsmith,et al.  Pyroelectric IR sensor arrays for fall detection in the older population , 2005 .

[2]  M. D. Addlesee,et al.  The ORL Active Floor , 1997 .

[3]  F. Livesey,et al.  The ORL active floor [sensor system] , 1997, IEEE Wirel. Commun..

[4]  J. Gerberding,et al.  Fatalities and injuries from falls among older adults--United States, 1993-2003 and 2001-2005. , 2006, MMWR. Morbidity and mortality weekly report.

[5]  James M. Keller,et al.  Toward a Passive Low-Cost In-Home Gait Assessment System for Older Adults , 2013, IEEE Journal of Biomedical and Health Informatics.

[6]  James M. Keller,et al.  Radar walking speed measurements of seniors in their apartments: Technology for fall prevention , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  C. Moran,et al.  Early mortality after hip fracture: is delay before surgery important? , 2005, The Journal of bone and joint surgery. American volume.

[8]  Liang Liu,et al.  Doppler radar sensor positioning in a fall detection system , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Michael F. Otero,et al.  Application of a continuous wave radar for human gait recognition , 2005, SPIE Defense + Commercial Sensing.

[10]  Shuang Wang,et al.  Activity Density Map Visualization and Dissimilarity Comparison for Eldercare Monitoring , 2012, IEEE Transactions on Information Technology in Biomedicine.

[11]  Liang Liu,et al.  Gait characterization via pulse-Doppler radar , 2011, 2011 IEEE International Conference on Pervasive Computing and Communications Workshops (PERCOM Workshops).

[12]  Liang Liu,et al.  Fall detection using doppler radar and classifier fusion , 2012, Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics.

[13]  S. L. Murphy Deaths: final data for 1998. , 2000, National vital statistics reports : from the Centers for Disease Control and Prevention, National Center for Health Statistics, National Vital Statistics System.

[14]  Derek Anderson,et al.  Falls, Technology, and Stunt Actors: New Approaches to Fall Detection and Fall Risk Assessment , 2008, Journal of nursing care quality.

[15]  Liang Liu,et al.  Automatic fall detection based on Doppler radar motion signature , 2011, 2011 5th International Conference on Pervasive Computing Technologies for Healthcare (PervasiveHealth) and Workshops.

[16]  Tanvi Banerjee,et al.  Improvement of acoustic fall detection using Kinect depth sensing , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[17]  National Center for Injury Prevention and Control: statistics and activities. , 1998, International journal of trauma nursing.

[18]  Marjorie Skubic,et al.  Unobtrusive, Continuous, In-Home Gait Measurement Using the Microsoft Kinect , 2013, IEEE Transactions on Biomedical Engineering.

[19]  M. Skubic,et al.  Older adults' attitudes towards and perceptions of ‘smart home’ technologies: a pilot study , 2004, Medical informatics and the Internet in medicine.