Combinatorial weighting method for lightning transformation effect evaluation of 500kV transmission lines

As the effective lightning protection measures can improve the lightning protection performance of transmission line and reduce line shielding failure rate, an assessment method based on combinatorial weighting method is proposed to formulate lightning protection measures in accordance with the e valuation process of screen-selection-optimization. Economic and technical analysis of several commonly used lightning transformations is performed first to verify their effectiveness. Then the combinatorial weighting method is applied to calculate the weight value of these measures relative to the target according to the relationship between objectives and guidelines, furthermore the theoretical optimal lightning protection measure is selected. The application of this method is illustrate d with a typical 500 kV transmission line under complex terrain, and the expected evaluation result shows the lightning protection performance can meet the transformation requirements. Thus this method can be suitably used as reference in practical engineering.

[1]  Wang Xin,et al.  Combinatorial Weighting Method for Comprehensive Evaluation of Construction Machinery Performance , 2010, 2010 Third International Conference on Information and Computing.

[2]  Lingyu Zhang,et al.  Dynamic lightning protection of Smart Grid transmission system , 2012, 2012 International Conference on Lightning Protection (ICLP).

[3]  Zhang Bo,et al.  Evaluation method for power supply service quality based on combinatorial weighting method and grey relational degree , 2011, 2011 IEEE 3rd International Conference on Communication Software and Networks.

[4]  Lu Zhiwei,et al.  The lightning protection performance of back striking for double-circuit transmission line based on the distributed transmission line tower model , 2011, 2011 7th Asia-Pacific International Conference on Lightning.

[5]  Hu Wen,et al.  Research on Differentiated Lightning Protection Comprehensive Management for the 500-kV Power Network in the Area Near the Three Gorges Project , 2012, IEEE Transactions on Power Delivery.

[6]  M. B. Daigavane,et al.  A Novel Technique to Reduce the Lightning Effect on Transmission Line , 2009, 2009 Second International Conference on Emerging Trends in Engineering & Technology.

[7]  Vijay Vittal,et al.  A Practical Evaluation of Surge Arrester Placement for Transmission Line Lightning Protection , 2010, IEEE Transactions on Power Delivery.

[9]  A. S. Morched,et al.  Transmission line arrester energy, cost, and risk of failure analysis for partially shielded transmission lines , 2000 .

[10]  A.T. Eshlaghy,et al.  A New Approach for Classification of Weighting Methods , 2006, 2006 IEEE International Conference on Management of Innovation and Technology.