Stimulus-driven versus pilocarpine-induced biometric changes in pseudophakic eyes.

Purpose Most trials that study the lens movement of accommodative intraocular lens (IOLs) use pilocarpine to stimulate ciliary muscle contraction. The aim of this study is to assess in vivo whether a more physiologic, stimulus-driven accommodation is comparable to pilocarpine-induced IOL movement. Design Controlled patient- and examiner-masked clinical trial. Participants The study population included 38 eyes with accommodative IOL implants (1CU) and a control group of 28 eyes with conventional open-loop IOLs. Methods A high-precision biometry technique, partial coherence interferometry, was used to measure IOL position. Anterior chamber depth was measured during physiologic (near point) and pharmacological (pilocarpine 2 % ) stimulation. In a subgroup of 14 1CU eyes, IOL position was determined repeatedly within 90 minutes after pilocarpine administration. A different subgroup was investigated as to the effect of cyclopentolate on IOL position. Best-corrected distance visual acuity (VA), best-corrected near VA, and distance-corrected near VA (DCNVA) were assessed using logarithm of the minimum angle of resolution charts. Main outcome measures Anterior chamber depth change under pilocarpine and near-point–driven accommodation. Results Near-point accommodation did not induce movement of either the accommodating 1CU or the control IOLs. Pilocarpine induced a 201±0.137-mm anterior movement of the 1CU IOL ( P P >0.05). There was no significant ( P >0.05) difference in DCNVA between the accommodative and open-loop IOLs. No correlation between near point– or pilocarpine-stimulated IOL movement and DCNVA was found. Concerning the time course of movement after pilocarpine administration, most of the 1CU IOLs showed some movement 30 minutes after application. Cyclopentolate-induced ciliary muscle relaxation caused a posterior IOL movement, as compared with the relaxed state, when focusing on a distant target. Conclusion Pilocarpine-induced ciliary muscle contraction seems to overestimate IOL movement relative to a monocular near-driven stimulus. Therefore, concerning IOL movement, pilocarpine may act as a superstimulus and may not adequately simulate daily life performance of accommodative IOLs. However, it may be helpful to evaluate the maximum potential of an accommodating IOL.

[1]  M. Snead,et al.  Pseudophakic accommodation? A study of the stability of capsular bag supported, one piece, rigid tripod, or soft flexible implants. , 1990, The British journal of ophthalmology.

[2]  Wolfgang Drexler,et al.  Laserinterferometric assessment of pilocarpine-induced movement of an accommodating intraocular lens: a randomized trial. , 2004, Ophthalmology.

[3]  Nhung X Nguyen,et al.  Implantation of a new accommodative posterior chamber intraocular lens. , 2002, Journal of refractive surgery.

[4]  Ken Hayashi,et al.  Aging changes in apparent accommodation in eyes with a monofocal intraocular lens. , 2003, American journal of ophthalmology.

[5]  M Nakazawa,et al.  Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses. , 1983, American journal of ophthalmology.

[6]  Y. Yamada,et al.  Accommodative intraocular lens with spring action. Part 1. Design and placement in an excised animal eye. , 1990, Ophthalmic surgery.

[7]  G. Sanderson,et al.  Apparent accommodation and depth of field in pseudophakia , 1996, Journal of cataract and refractive surgery.

[8]  W. Drexler,et al.  Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes , 2003, Journal of cataract and refractive surgery.

[9]  Adolf Friedrich Fercher Optical coherence tomography. , 1996 .

[10]  C K Hitzenberger,et al.  Accurate determination of effective lens position and lens‐capsule distance with 4 intraocular lenses , 1998, Journal of cataract and refractive surgery.

[11]  P. Kaufman,et al.  The mechanism of accommodation in primates. , 1999, Ophthalmology.

[12]  J S Cumming,et al.  Clinical evaluation of the model AT-45 silicone accommodating intraocular lens: results of feasibility and the initial phase of a Food and Drug Administration clinical trial. , 2001, Ophthalmology.

[13]  F Verzella,et al.  Multifocal effect of against-the-rule myopic astigmatism in pseudophakic eyes. , 1993, Refractive & corneal surgery.

[14]  A. Fercher,et al.  Eye elongation during accommodation in humans: differences between emmetropes and myopes. , 1998, Investigative ophthalmology & visual science.

[15]  O. Nishi,et al.  Accommodation amplitude after lens refilling with injectable silicone by sealing the capsule with a plug in primates. , 1998, Archives of ophthalmology.

[16]  L Werner,et al.  Pseudoaccommodation: BioComFold versus a foldable silicone intraocular lens. , 1999, Journal of cataract and refractive surgery.

[17]  Adolf Friedrich Fercher,et al.  Ophthalmic Laser Interferometry , 1986, Other Conferences.

[18]  C K Hitzenberger,et al.  Improved prediction of intraocular lens power using partial coherence interferometry , 2001, Journal of cataract and refractive surgery.

[19]  J. Holladay,et al.  Avoiding refractive problems in cataract surgery. , 1988, Survey of ophthalmology.

[20]  M. Leyland,et al.  Multifocal versus monofocal intraocular lenses in cataract surgery: a systematic review. , 2003, Ophthalmology.

[21]  C K Hitzenberger,et al.  High precision biometry of pseudophakic eyes using partial coherence interferometry , 1998, Journal of cataract and refractive surgery.

[22]  A Vogel,et al.  [Experimental studies of the risks of endocapsular polymerization of injectable intraocular lenses]. , 1995, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[23]  T. Oshika,et al.  Relationship between apparent accomodation and corneal multifocality in pseudophakic eyes. , 1999, Ophthalmology.

[24]  J T Holladay,et al.  Refractive power calculations for intraocular lenses in the phakic eye. , 1993, American journal of ophthalmology.

[25]  Wolfgang Drexler,et al.  Intraocular lens movement caused by ciliary muscle contraction , 2003, Journal of cataract and refractive surgery.

[26]  Gerd U. Auffarth,et al.  Measuring anterior chamber depth with the Orbscan Topography System , 1997, Journal of cataract and refractive surgery.

[27]  O. Nishi,et al.  Capsule opacification after refilling the capsule with an inflatable endocapsular balloon , 1997, Journal of cataract and refractive surgery.

[28]  K. Ciuffreda,et al.  Accommodation, Nearwork and Myopia , 1997 .

[29]  Jack T. Holladay,et al.  Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations , 1997, Journal of cataract and refractive surgery.

[30]  Apparent accommodation and corneal wavefront aberration in pseudophakic eyes. , 2002, Investigative ophthalmology & visual science.