Filter calculation for x-ray tomosynthesis reconstruction.

Filtered backprojection reconstruction is an efficient image reconstruction method which is widely used in CT and 3D x-ray imaging. The way data have to be filtered depends on the acquisition geometry and the number of projections (views) which were acquired. For standard geometries like circle or helix it is known how to effectively filter the data. But there are acquisition geometries for which the application of standard filters yields poor results, e.g. in situations where the number of views is very small or for a limited angular range. In tomosynthesis, both conditions apply, i.e. the number of projections is typically very small and, moreover, the angular coverage is much less than 180°. This paper proposes a new method to design effective filters which are specific for the acquisition geometry. Examples from x-ray tomosynthesis are utilized to demonstrate the excellent performance of the proposed method.

[1]  Bernhard Erich Hermann Claus,et al.  Tomosynthesis imaging with 2D scanning trajectories , 2011, Medical Imaging.

[2]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[3]  Thomas Mertelmeier,et al.  Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device , 2006, SPIE Medical Imaging.

[4]  Xiaochuan Pan,et al.  Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms. , 2009, Medical physics.

[5]  N. Pelc,et al.  Filtered backprojection for modifying the impulse response of circular tomosynthesis. , 2001, Medical physics.

[6]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[7]  D. Kopans,et al.  Tomographic mammography using a limited number of low-dose cone-beam projection images. , 2003, Medical physics.

[8]  Lubomir M. Hadjiiski,et al.  A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis. , 2006, Medical physics.

[9]  Thomas Mertelmeier,et al.  A Novel Approach for Filtered Backprojection in Tomosynthesis Based on Filter Kernels Determined by Iterative Reconstruction Techniques , 2008, Digital Mammography / IWDM.

[10]  K Bliznakova,et al.  Evaluation of digital breast tomosynthesis reconstruction algorithms using synchrotron radiation in standard geometry. , 2010, Medical physics.

[11]  G. Herman,et al.  Linograms in Image Reconstruction from Projections , 1987, IEEE Transactions on Medical Imaging.

[12]  D. Godfrey,et al.  Optimization of the matrix inversion tomosynthesis (MITS) impulse response and modulation transfer function characteristics for chest imaging. , 2006, Medical physics.

[13]  Paola Coan,et al.  X-ray phase-contrast imaging: from pre-clinical applications towards clinics , 2013, Physics in medicine and biology.

[14]  Mario Bertero,et al.  Introduction to Inverse Problems in Imaging , 1998 .

[15]  Wei Zhao,et al.  Three-dimensional linear system analysis for breast tomosynthesis. , 2008, Medical physics.

[16]  Günter Lauritsch,et al.  Theoretical framework for filtered back projection in tomosynthesis , 1998, Medical Imaging.

[17]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[18]  Leon Kaufman,et al.  A general algorithm for oblique image reconstruction , 1990, IEEE Computer Graphics and Applications.

[19]  L. Landweber An iteration formula for Fredholm integral equations of the first kind , 1951 .

[20]  Maria Magnusson,et al.  The linogram method for image reconstruction from projections applied to fan-beam projection data , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[21]  Laurie L Fajardo,et al.  Breast tomosynthesis: present considerations and future applications. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.