Seismic behaviour of composite concrete-filled tube column-to-beam moment connections

Abstract This paper describes the results of cyclic loading applied to seven square concrete-filled tube column-to-beam connections. Connections of all seven specimens were reinforced with T-shaped stiffeners attached to the beam flanges. The specimens are divided into three series: the TS series specimens were reinforced with T-shaped stiffeners only; those in the TSD series had RBS beams in addition to the stiffeners; and those in the TSH series had small holes in the stiffeners. The test results presented in terms of the ductility capacity of the test specimens. All the specimens developed plastic rotations in excess of 3% rad, suggesting that the ductility capacity of the specimens exceeds the requirements for special moment frame connections in the AISC seismic provisions. The tapered horizontal stiffener elements, RBS cutouts and the horizontal stiffener holes were effective in reducing the stress concentration at the tip of the horizontal element. However, some of the specimens failed by a premature fracture in the HAZ of vertical element welds, suggesting that in designing the T-stiffeners strain hardening should be considered.

[1]  I. Nishiyama,et al.  INELASTIC FORCE-DEFORMATION RESPONSE OF JOINT SHEAR PANELS IN BEAM-COLUMN MOMENT CONNECTIONS TO CONCRETE-FILLED TUBES , 2004 .

[2]  Hiroshi Akiyama,et al.  ULTIMATE ENERGY ABSORPTION CAPACITY OF SLIT-TYPE STEEL PLATES SUBJECTED TO SHEAR DEFORMATIONS , 1998 .

[3]  Atorod Azizinamini,et al.  Experimental behavior of steel beam to CFT column connections , 2001 .

[4]  Masayoshi Nakashima,et al.  Tests of Welded Beam-Column Subassemblies. I: Global Behavior , 1998 .

[5]  N. E. Shanmugam,et al.  Welded Interior Box-Column to I-Beam Connections , 1995 .

[6]  James M. Ricles,et al.  Seismic Behavior of Composite Concrete Filled Steel Tube Column-Wide Flange Beam Moment Connections , 2004 .

[7]  Hiroshi Masuda,et al.  EXPERIMENTAL STUDY ON THE STATICAL CHARACTERISTICS OF PERIMETER BEAM-TO-SHS COLUMN CONECTIONS USING VERTICAL STIFFENER PLATES , 2000 .

[8]  Masayoshi Nakashima,et al.  Steel moment frames for earthquakes in United States and Japan , 2000 .

[9]  Yousef.M. Alostaz,et al.  Experimental Behavior of Connections to Concrete-filled Steel Tubes , 1998 .

[10]  Satoshi Yamada,et al.  Experimental method of the full scale shaking table test using the inertial loading equipment , 2021, Behaviour of Steel Structures in Seismic Areas.

[11]  R. Narayanan Steel-concrete composite structures , 1988 .

[12]  Chiaki Matsui,et al.  Structural Performance of H-shaped Steel Beam to Square Tube Steel Column Connection using Vertical Stiffeners , 2000 .

[13]  Young Suk Oh,et al.  Non-linear Analysis of Full Scaled CFT Column to H-Beam Connections with T-Stiffeners , 2002 .

[14]  Young-Suk Oh,et al.  Behavior of welded CFT column to H-beam connections with external stiffeners , 2004 .

[15]  Chin-Tung Cheng,et al.  Seismic performance of steel beams to concrete-filled steel tubular column connections , 2003 .

[16]  Kyung-Jae Shin,et al.  Hysteresis behavior of CFT column to H-beam connections with external T-stiffeners and penetrated elements , 2001 .