Poor accuracy of freehand cup positioning during total hip arthroplasty

Several studies have demonstrated a correlation between the acetabular cup position and the risk of dislocation, wear and range of motion after total hip arthroplasty. The present study was designed to evaluate the accuracy of the surgeon’s estimated position of the cup after freehand placement in total hip replacement. Peroperative estimated abduction and anteversion of 200 acetabular components (placed by three orthopaedic surgeons and nine residents) were compared with measured outcomes (according to Pradhan) on postoperative radiographs. Cups were placed in 49.7° (SD 6.7) of abduction and 16.0° (SD 8.1) of anteversion. Estimation of placement was 46.3° (SD 4.3) of abduction and 14.6° (SD 5.9) of anteversion. Of more interest is the fact that for the orthopaedic surgeons the mean inaccuracy of estimation was 4.1° (SD 3.9) for abduction and 5.2° (SD 4.5) for anteversion and for their residents this was respectively, 6.3° (SD 4.6) and 5.7° (SD 5.0). Significant differences were found between orthopaedic surgeons and residents for inaccuracy of estimation for abduction, not for anteversion. Body mass index, sex, (un)cemented fixation and surgical approach (anterolateral or posterolateral) were not significant factors. Based upon the inaccuracy of estimation, the group’s chance on future cup placement within Lewinnek’s safe zone (5–25° anteversion and 30–50° abduction) is 82.7 and 85.2% for anteversion and abduction separately. When both parameters are combined, the chance of accurate placement is only 70.5%. The chance of placement of the acetabular component within 5° of an intended position, for both abduction and anteversion is 21.5% this percentage decreases to just 2.9% when the tolerated error is 1°. There is a tendency to underestimate both abduction and anteversion. Orthopaedic surgeons are superior to their residents in estimating abduction of the acetabular component. The results of this study indicate that freehand placement of the acetabular component is not a reliable method.

[1]  R. Pradhan,et al.  Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. , 1999, The Journal of bone and joint surgery. British volume.

[2]  B. Morrey,et al.  Effects of acetabular abduction on cup wear rates in total hip arthroplasty. , 1998, The Journal of arthroplasty.

[3]  D. McCollum,et al.  Dislocation after total hip arthroplasty. Causes and prevention. , 1990, Clinical orthopaedics and related research.

[4]  D. D’Lima,et al.  The Effect of the Orientation of the Acetabular and Femoral Components on the Range of Motion of the Hip at Different Head-Neck Ratios* , 2000, The Journal of bone and joint surgery. American volume.

[5]  J. Lewis,et al.  Dislocations after total hip-replacement arthroplasties. , 1978, The Journal of bone and joint surgery. American volume.

[6]  Branislav Jaramaz,et al.  Comparison of a mechanical acetabular alignment guide with computer placement of the socket. , 2002, The Journal of arthroplasty.

[7]  J. Olsen,et al.  Causes and Prevention , 1991, Scandinavian journal of social medicine.

[8]  R. Steffen,et al.  The accuracy of free-hand cup positioning - a CT based measurement of cup placement in 105 total hip arthroplasties , 2004, International Orthopaedics.

[9]  B. Jolles,et al.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis. , 2002, The Journal of arthroplasty.

[10]  Brigitte M Jolles,et al.  Computer-assisted Cup Placement Techniques in Total Hip Arthroplasty Improve Accuracy of Placement , 2004, Clinical orthopaedics and related research.

[11]  B. Jaramaz,et al.  Computer Assisted Measurement of Cup Placement in Total Hip Replacement , 1998, Clinical orthopaedics and related research.

[12]  L. Fabeck,et al.  A method to measure acetabular cup anteversion after total hip replacement. , 1999, Acta orthopaedica Belgica.

[13]  B. Zurfluh,et al.  Compliant positioning of total hip components for optimal range of motion , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[14]  Burkhard Lembeck,et al.  Pelvic tilt makes acetabular cup navigation inaccurate , 2005, Acta orthopaedica.

[15]  Karl-Heinz Widmer,et al.  A simplified method to determine acetabular cup anteversion from plain radiographs. , 2004, The Journal of arthroplasty.