Comparison of surfactants for dynamic surface modification of poly(dimethylsiloxane) microchips

In the present report, the use of negatively charged surfactants as modifiers of the background electrolyte is reported using poly(dimethylsiloxane) (PDMS) microchips. In particular, the use of anionic surfactants, such as sodium dodecyl sulfate, phosphatidic acid, and deoxycholate, was studied. When surfactants were present in the run buffer, an increase in the electroosmotic flow (EOF) was observed. Two additional effects were also observed: (i) stabilization of the run‐to‐run EOF, (ii) an improvement in the electrochemical response for several biomolecules. In order to characterize the analysis conditions, the effects of different surfactant, electrolyte, and pH were studied. EOF measurements were performed using either the current monitoring method or by detection of a neutral molecule. The first adsorption/desorption kinetics studies are also reported for different surfactants onto PDMS. The separation of biologically important analytes (glucose, penicillin, phenol, and homovanillic acid) was improved decreasing the analysis time from 200 to 125 s. However, no significant changes in the number of theoretical plates were observed.

[1]  W. Kuhr,et al.  Microchip capillary electrophoresis coupled to sinusoidal voltammetry for the detection of native carbohydrates , 2002, Electrophoresis.

[2]  Annelise E Barron,et al.  Microchannel wall coatings for protein separations by capillary and chip electrophoresis , 2003, Electrophoresis.

[3]  H. Becker,et al.  Polymer microfluidic devices. , 2002, Talanta.

[4]  Gang Chen,et al.  Microchip capillary electrophoresis with electrochemical detector for fast measurements of aromatic amino acids. , 2003, Talanta.

[5]  Yan Liu,et al.  Versatile 3-channel high-voltage power supply for microchip capillary electrophoresis. , 2003, Lab on a chip.

[6]  Keisuke Matsuoka,et al.  Micelle formation of sodium deoxycholate and sodium ursodeoxycholate (part 1). , 2002, Biochimica et biophysica acta.

[7]  C. Fujimoto Titanium dioxide coated surfaces for capillary electrophoresis and capillary electrochromatography , 2002, Electrophoresis.

[8]  Joseph Wang,et al.  Electrochemical detection for microscale analytical systems: a review. , 2002, Talanta.

[9]  Charles S Henry,et al.  Direct detection of renal function markers using microchip CE with pulsed electrochemical detection. , 2004, The Analyst.

[10]  Masaru Kato,et al.  Rapid analysis of amino acids in Japanese green tea by microchip electrophoresis using plastic microchip and fluorescence detection. , 2003, Journal of chromatography. A.

[11]  M. J. Chen,et al.  Capillary electrophoresis study on the micellization and critical micelle concentration of sodium dodecyl sulfate. Influence of solubilized solutes. , 2001, Journal of chromatography. A.

[12]  D. J. Harrison,et al.  Electrokinetic control of fluid flow in native poly(dimethylsiloxane) capillary electrophoresis devices , 2000, Electrophoresis.

[13]  C. Henry,et al.  Experimental studies of electroosmotic flow dynamics in microfabricated devices during current monitoring experiments. , 2003, Analytical chemistry.

[14]  A. Ewing,et al.  Amperometric detection of catechols in capillary zone electrophoresis with normal and micellar solutions. , 1988, Analytical chemistry.

[15]  Adam Eckhardt,et al.  Comparison of standard capillary and chip separations of sodium dodecylsulfate-protein complexes. , 2003, Journal of chromatography. A.

[16]  Frank Kohler,et al.  Poly(vinyl alcohol)‐coated microfluidic devices for high‐performance microchip electrophoresis , 2002, Electrophoresis.

[17]  Sun-Young Lee,et al.  Lipid interaction of α‐synuclein during the metal‐catalyzed oxidation in the presence of Cu2+ and H2O2 , 2003, Journal of neurochemistry.

[18]  C. Bush,et al.  Carbohydrate analysis of bacterial polysaccharides by high-pH anion-exchange chromatography and online polarimetric determination of absolute configuration. , 2002, Analytical biochemistry.

[19]  Hossein Salimi-Moosavi,et al.  Protein separation and surfactant control of electroosmotic flow in poly(dimethylsiloxane)-coated capillaries and microchips. , 2002, Journal of chromatography. A.

[20]  C. Henry,et al.  Dynamic coating using polyelectrolyte multilayers for chemical control of electroosmotic flow in capillary electrophoresis microchips. , 2000, Analytical chemistry.

[21]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[22]  G. Whitesides,et al.  Components for integrated poly(dimethylsiloxane) microfluidic systems , 2002, Electrophoresis.

[23]  S. Shamsi,et al.  Capillary electrochromatography of Triton X‐100 , 2004, Electrophoresis.

[24]  E. Hasselbrink,et al.  Zeta potential of microfluidic substrates: 1. Theory, experimental techniques, and effects on separations , 2004, Electrophoresis.

[25]  Charles S. Henry,et al.  Enhanced determination of glucose by microchip electrophoresis with pulsed amperometric detection , 2004 .

[26]  Hong Yu,et al.  Direct determination of free amino acids and sugars in green tea by anion-exchange chromatography with integrated pulsed amperometric detection. , 2002, Journal of chromatography. A.

[27]  E. Hasselbrink,et al.  Zeta potential of microfluidic substrates: 2. Data for polymers , 2004, Electrophoresis.

[28]  Nancy Allbritton,et al.  Surface modification of poly(dimethylsiloxane) microfluidic devices by ultraviolet polymer grafting. , 2002, Analytical chemistry.

[29]  Elisabeth Verpoorte,et al.  Comparison of the performance characteristics of poly(dimethylsiloxane) and Pyrex microchip electrophoresis devices for peptide separations. , 2003, Journal of chromatography. A.