Improving sensitivity in nonlinear Raman microspectroscopy imaging and sensing.
暂无分享,去创建一个
Rajan Arora | Georgi I Petrov | Vladislav V Yakovlev | Jian Liu | V. Yakovlev | G. Petrov | R. Arora | Jian Liu
[1] Conor L Evans,et al. Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy. , 2005, Proceedings of the National Academy of Sciences of the United States of America.
[2] Conor L Evans,et al. Coherent anti-stokes raman scattering spectral interferometry: determination of the real and imaginary components of nonlinear susceptibility chi(3) for vibrational microscopy. , 2004, Optics letters.
[3] M. Belić,et al. Combined stimulated Raman scattering and continuum self-phase modulations , 1980 .
[4] Thomas Seeger,et al. Application of 266-nm and 355-nm Nd:YAG laser radiation for the investigation of fuel-rich sooting hydrocarbon flames by raman scattering. , 2004, Applied optics.
[5] B. Dietzek,et al. Raman and CARS microspectroscopy of cells and tissues. , 2009, The Analyst.
[6] M. Gruebele,et al. High speed nonlinear interferometric vibrational analysis of lipids by spectral decomposition. , 2010, Analytical chemistry.
[7] Klaus Suhling,et al. Multiphoton Microscopy in the Biomedical Sciences Vii , 2002 .
[8] B. Wilson,et al. In Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications , 1998, Photochemistry and photobiology.
[9] K J Halbhuber,et al. Pulse-length dependence of cellular response to intense near-infrared laser pulses in multiphoton microscopes. , 1999, Optics letters.
[10] James R. Gord,et al. Single-beam coherent anti-Stokes Raman scattering spectroscopy of N2 using a shaped 7 fs laser pulse , 2009 .
[11] Marlan O Scully,et al. Coherent versus incoherent Raman scattering: molecular coherence excitation and measurement. , 2007, Optics letters.
[12] Tak W. Kee,et al. Simple approach to one-laser, broadband coherent anti-Stokes Raman scattering microscopy. , 2004, Optics letters.
[13] M. Motzkus,et al. Highly sensitive single-beam heterodyne coherent anti-Stokes Raman scattering. , 2006, Optics letters.
[14] R. Weissleder. Molecular Imaging in Cancer , 2006, Science.
[15] W. Webb,et al. Live tissue intrinsic emission microscopy using multiphoton-excited native fluorescence and second harmonic generation , 2003, Proceedings of the National Academy of Sciences of the United States of America.
[16] M. S. Zubairy,et al. FAST CARS: Engineering a laser spectroscopic technique for rapid identification of bacterial spores , 2002, Proceedings of the National Academy of Sciences of the United States of America.
[17] Jennifer P Ogilvie,et al. Comparing coherent and spontaneous Raman scattering under biological imaging conditions. , 2009, Optics letters.
[18] Riyi Shi,et al. Coherent anti-stokes Raman scattering imaging of axonal myelin in live spinal tissues. , 2005, Biophysical journal.
[19] P O'Neill,et al. Use of near infrared femtosecond lasers as sub-micron radiation microbeam for cell DNA damage and repair studies. , 2010, Mutation research.
[20] Vladislav V. Yakovlev,et al. Comparison of coherent and spontaneous Raman microspectroscopies for noninvasive detection of single bacterial endospores , 2007, Proceedings of the National Academy of Sciences.
[21] Chinlon Lin,et al. New nanosecond continuum for excited-state spectroscopy , 1976 .
[22] Shi-Wei Chu,et al. Wavelength dependent damage in biological multi-photon confocal microscopy: A micro-spectroscopic comparison between femtosecond Ti:sapphire and Cr:forsterite laser sources , 2002 .
[23] G. Ripandelli,et al. Optical coherence tomography. , 1998, Seminars in ophthalmology.
[24] Rajan Arora,et al. Analytical capabilities of coherent anti-Stokes Raman scattering microspectroscopy , 2008, Journal of modern optics.
[25] John White,et al. Long-term two-photon fluorescence imaging of mammalian embryos without compromising viability , 1999, Nature Biotechnology.
[26] Virginijus Barzda,et al. Visualization of mitochondria in cardiomyocytes by simultaneous harmonic generation and fluorescence microscopy. , 2005, Optics express.
[27] Leslie M Loew,et al. Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms , 2003, Nature Biotechnology.
[28] M D Duncan,et al. Scanning coherent anti-Stokes Raman microscope. , 1982, Optics letters.
[29] N. Ramanujam,et al. In vivo multiphoton microscopy of NADH and FAD redox states, fluorescence lifetimes, and cellular morphology in precancerous epithelia , 2007, Proceedings of the National Academy of Sciences.
[30] Yaron Silberberg,et al. Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy , 2002, Nature.
[31] Adrien E. Desjardins,et al. Real-Time FPGA Processing for High-Speed Optical Frequency Domain Imaging , 2009, IEEE Transactions on Medical Imaging.
[32] S. Hewitt,et al. Infrared spectroscopic imaging for histopathologic recognition , 2005, Nature Biotechnology.
[33] Erik M. Vartiainen,et al. Phase retrieval approach for coherent anti-Stokes Raman scattering spectrum analysis , 1992 .
[34] Vladislav V. Yakovlev. Advanced instrumentation for non‐linear Raman microscopy , 2003 .
[35] Ji-Xin Cheng,et al. Label-free molecular imaging of atherosclerotic lesions using multimodal nonlinear optical microscopy. , 2007, Journal of biomedical optics.
[36] Andreas Volkmer,et al. Vibrational imaging and microspectroscopies based on coherent anti-Stokes Raman scattering microscopy , 2005 .
[37] Vladislav V. Yakovlev,et al. Broadband nonlinear optical conversion of a high-energy diode-pumped picosecond laser , 2004 .
[38] Lihong V Wang,et al. Photoacoustic tomography and sensing in biomedicine , 2009, Physics in medicine and biology.
[39] Yukihiro Ozaki,et al. Multivariate data analysis for Raman spectroscopic imaging , 2009 .
[40] Marcos Dantus,et al. Coherent mode-selective Raman excitation towards standoff detection. , 2008, Optics express.
[41] Jane A Dickerson,et al. Current Applications of Liquid Chromatography / Mass Spectrometry in Pharmaceutical Discovery After a Decade of Innovation , 2008 .
[42] Marlan O Scully,et al. Optimizing the Laser-Pulse Configuration for Coherent Raman Spectroscopy , 2007, Science.
[43] M. Alfimov,et al. Microjoule supercontinuum generation by stretched megawatt femtosecond laser pulses in a large-mode-area photonic-crystal fiber , 2007, 2007 European Conference on Lasers and Electro-Optics and the International Quantum Electronics Conference.
[44] W. R. Wiley,et al. Three-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman Scattering , 1999 .
[45] P. Vandenabeele,et al. Reference database of Raman spectra of biological molecules , 2007 .
[46] M. Levenson,et al. Optically heterodyned coherent Raman spectroscopy , 1978 .
[47] Gary D Noojin,et al. ED50 study of femtosecond terawatt laser pulses on porcine skin , 2005, Lasers in surgery and medicine.
[48] J. Limpert,et al. High Repetition Rate Gigawatt Peak Power Fiber Laser Systems: Challenges, Design, and Experiment , 2009, IEEE Journal of Selected Topics in Quantum Electronics.
[49] Müller,et al. CARS microscopy with folded BoxCARS phasematching , 2000, Journal of microscopy.
[50] R. Narayan,et al. Maximum Entropy Image Restoration in Astronomy , 1986 .
[51] Hiro-o Hamaguchi,et al. Femtosecond coherent anti-Stokes Raman scattering spectroscopy using supercontinuum generated from a photonic crystal fiber , 2004 .
[52] W. Tolles,et al. A Comparative Analysis of the Analytical Capabilities of Coherent Anti-Stokes Raman Spectroscopy (CARS) Relative to Raman Scattering and Absorption Spectroscopy , 1977 .
[53] Irving Itzkan,et al. Confocal light absorption and scattering spectroscopic microscopy monitors organelles in live cells with no exogenous labels , 2007, Proceedings of the National Academy of Sciences.
[54] E. Sevick-Muraca,et al. Quantitative optical spectroscopy for tissue diagnosis. , 1996, Annual review of physical chemistry.
[55] M. Diem,et al. Fourier transform infrared (FTIR) spectral mapping of the cervical transformation zone, and dysplastic squamous epithelium. , 2004, Gynecologic oncology.
[56] V. V. Yakovlev,et al. Raman versus CARS microscopy: when one is better than the other , 2007, SPIE BiOS.
[57] Vladislav Yakovlev,et al. Enhancing red-shifted white-light continuum generation in optical fibers for applications in nonlinear Raman microscopy. , 2005, Optics express.
[58] H. G. Schulze,et al. In situ analysis of living embryonic stem cells by coherent anti-stokes Raman microscopy. , 2007, Analytical chemistry.
[59] Tak W. Kee,et al. One-laser interferometric broadband coherent anti-Stokes Raman scattering. , 2006, Optics express.
[60] I. Hartl,et al. Ultrafast Fiber Laser Technology , 2009, IEEE Journal of Selected Topics in Quantum Electronics.
[61] K. König,et al. Cell damage by near-IR microbeams , 1995, Nature.
[62] Alexei V. Sokolov,et al. Glucose concentration measured by the hybrid coherent anti-Stokes Raman-scattering technique , 2010 .
[63] A. Welch,et al. A review of the optical properties of biological tissues , 1990 .
[64] Ulrike Tauer,et al. Advantages and Risks of Multiphoton Microscopy in Physiology , 2002, Experimental physiology.
[65] R. Buczyński. Photonic Crystal Fibers , 2004 .
[66] Vladislav V. Yakovlev,et al. Advances in real-time nonlinear Raman microscopy , 2001, SPIE BiOS.
[67] B S Hudson. New laser techniques for biophysical studies. , 1977, Annual review of biophysics and bioengineering.
[68] S W Hell,et al. Heating by absorption in the focus of an objective lens. , 1998, Optics letters.