Correlation of Internal Jugular Vein/Common Carotid Artery Ratio to Central Venous Pressure: A Pilot Study in Pediatric Burn Patients

The purpose of this pilot study was to identify the relationship between the ratio of the diameter/cross-sectional area of the internal jugular vein (IJV) and carotid artery and the central venous pressure (CVP). After obtaining approval from our Institutional Review Board, ultrasound images were repeatedly obtained from participants on consecutive days when a thoracic central line was in place. The CVP was then measured in standardized fashion, using our bedside monitors. A blinded observer measured the diameter of the common carotid artery and IJV, for comparison. Similarly, digital images were analyzed to compare an estimate of the cross-sectional areas of the same vessels. Six patients met enrollment criteria, and one patient was excluded after enrollment before any measurements being made. The remaining five patients had a mean age of 7 years (range: 9 months to 15 years) and mean burn size of 64% (SD, ±15), and no patients had inhalation injuries. All patients in this study were mechanically ventilated. Measurements were made from one patient while spontaneously breathing. One patient reading occurred while on vasopressor support (levophed at 2 &mgr;g/kg/hr). CVP values ranged from 1 to 25 mm Hg. Comparison of the ratio of the IJV/common carotid artery cross-sectional area with CVP revealed that a ratio of 2 or greater was associated with a CVP of at least 8 mm Hg (P < .001). These preliminary results suggest that if the cross-sectional area of the vein is at least twice that of the artery, then the CVP seems to be ≥8 mm Hg.

[1]  C. Moore,et al.  Point-of-care ultrasonography. , 2011, The New England journal of medicine.

[2]  E. Nemergut,et al.  Error in Central Venous Pressure Measurement , 2009, Anesthesia and analgesia.

[3]  Y. Asano,et al.  Change in Inferior Vena Caval Diameter Detected by Ultrasonography During and After Hemodialysis , 1995, ASAIO journal.

[4]  M. Roy,et al.  Defining normal jugular venous pressure with ultrasonography. , 2010, CJEM.

[5]  Y. Asano,et al.  The inferior vena cava diameter as a marker of dry weight in chronic hemodialyzed patients. , 1995, Artificial organs.

[6]  I. Krause,et al.  Inferior vena cava diameter: a useful method for estimation of fluid status in children on haemodialysis. , 2001, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[7]  B. Laviolle,et al.  Estimation of the diameter and cross-sectional area of the internal jugular veins in adult patients , 2009, Critical care.

[8]  D. Kusahara,et al.  Variability in the establishment of an external reference point for central venous pressure measurement in children. , 2006, Jornal de pediatria.

[9]  J. Schefold,et al.  Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis. , 2010, The Journal of emergency medicine.

[10]  Ognjen Gajic,et al.  Diagnostic accuracy of a simple ultrasound measurement to estimate central venous pressure in spontaneously breathing, critically ill patients. , 2009, Journal of hospital medicine.

[11]  M. Levy,et al.  Surviving Sepsis Campaign: International guidelines for management of severe sepsis and septic shock: 2008 , 2007, Intensive Care Medicine.

[12]  K. Chergui,et al.  Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients , 2004, Intensive Care Medicine.

[13]  J. Quinn,et al.  Correlation of sonographic measurements of the internal jugular vein with central venous pressure. , 2009, The American journal of emergency medicine.

[14]  Jukka Takala,et al.  Estimation of central venous pressure by ultrasound. , 2005, Resuscitation.